1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Immergas Victrix Zeus Superior ErP 32 kW condensing boiler. Please read this manual thoroughly before attempting any installation, operation, or maintenance procedures. Retain this manual for future reference.
2. Safety Information
Important Safety Instructions:
- Professional Installation Required: Installation, maintenance, and repair must be performed by qualified and authorized personnel only. Improper installation can lead to serious injury or property damage.
- Gas Safety: This appliance uses methane gas. Ensure all gas connections are secure and leak-free. In case of a gas leak, immediately shut off the gas supply, ventilate the area, and contact emergency services. Do not operate electrical switches.
- Electrical Safety: Ensure the boiler is properly grounded. Disconnect power before performing any service or maintenance. Do not operate the boiler with damaged electrical cords or components.
- Water Safety: The boiler operates with water. Ensure proper water pressure and check for leaks regularly.
- Ventilation: Ensure adequate ventilation as required by local regulations for gas appliances.
- Children and Pets: Keep children and pets away from the boiler area.
- Flammable Materials: Do not store flammable materials near the boiler.
Failure to follow these safety instructions could result in fire, explosion, electric shock, property damage, personal injury, or death.
3. Product Overview
The Immergas Victrix Zeus Superior ErP 32 kW is a high-efficiency condensing boiler designed for both heating and domestic hot water production. It features an integrated 54-liter stainless steel storage tank for optimal hot water performance.

Figure 1: Front view of the Immergas Victrix Zeus Superior ErP 32 kW Condensing Boiler. The image shows a white, wall-mounted unit with a central vertical seam and a control panel with a digital display at the bottom.
Key Features:
- High Efficiency: Optimized for heating and domestic hot water, meeting ErP and ELD European Directives for high energy efficiency classes.
- Integrated Storage Tank: 54-liter stainless steel tank ensures maximum hydraulic performance and excellent temperature regulation.
- Flexible Installation: Approved for indoor and partially protected outdoor installations.
- Electrical Protection: IPX5D electrical protection rating.
- Anti-freeze System: Standard anti-freeze protection down to -5 °C.
- Fuel Type: Methane gas.
4. Setup and Installation
WARNING: Installation must be carried out by a certified professional in accordance with all local and national regulations and codes.
General Installation Steps (Professional Guidance Required):
- Site Selection: Choose a suitable location for the boiler, considering ventilation, clearances, and access for maintenance. The boiler is approved for indoor or partially protected outdoor installation.
- Mounting: Securely mount the boiler to a sturdy wall using appropriate fixings.
- Hydraulic Connections: Connect the heating flow and return pipes, cold water inlet, and hot water outlet. Ensure all connections are watertight.
- Gas Connection: Connect the boiler to the methane gas supply. Perform a leak test on all gas connections.
- Flue System: Install the flue system according to manufacturer instructions and local regulations for safe exhaust gas discharge.
- Electrical Connection: Connect the boiler to the electrical supply (230V AC, 50Hz) ensuring proper grounding.
- Filling and Venting: Fill the heating system with water and thoroughly vent all air from the system.
- Initial Start-up: Follow the specific start-up procedure outlined in the professional installation manual, including checking operating pressures and temperatures.
5. Operating Instructions
Once installed and commissioned by a qualified technician, your Immergas Victrix Zeus Superior ErP 32 kW boiler is ready for operation.
Basic Operation:
- Power On/Off: Use the main power switch on the boiler or external control panel to turn the unit on or off.
- Heating Temperature Adjustment: Use the dedicated controls (usually a dial or buttons on the control panel) to set the desired heating water temperature for your radiators or underfloor heating system.
- Domestic Hot Water (DHW) Temperature Adjustment: Adjust the DHW temperature setting to your preference. The integrated 54-liter tank ensures a stable supply.
- Operating Modes: Your boiler may have different operating modes (e.g., Summer mode for DHW only, Winter mode for heating and DHW, Anti-freeze mode). Refer to the control panel interface for specific mode selection.
- System Pressure: Regularly check the system pressure gauge (typically located on the boiler's front panel). The recommended operating pressure is usually between 1.0 and 1.5 bar when the system is cold. If the pressure drops, consult the troubleshooting section or a qualified technician.
For detailed programming and advanced settings, refer to the specific control panel manual provided with your boiler.
6. Maintenance
Regular maintenance is crucial for the safe, efficient, and long-lasting operation of your Immergas boiler. All maintenance and servicing should be performed by a qualified and authorized service technician.
Recommended Maintenance Schedule:
- Annual Professional Service: Have your boiler inspected and serviced by a qualified technician at least once a year. This typically includes:
- Checking and cleaning the burner and heat exchanger.
- Inspecting the flue system for blockages or leaks.
- Checking gas and water connections for leaks.
- Verifying safety devices and controls.
- Testing combustion efficiency.
- Inspecting the expansion vessel and system pressure.
- User Checks (Monthly/Quarterly):
- System Pressure: Check the pressure gauge. If it's consistently low, consult a technician.
- Visual Inspection: Look for any visible leaks, unusual noises, or error codes on the display.
- Ventilation: Ensure air vents are not obstructed.
Do not attempt to repair the boiler yourself. Contact a qualified service technician for any issues beyond basic user checks.
7. Troubleshooting
This section provides solutions to common issues. For complex problems or if an error code persists, contact a qualified service technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| No Heating or Hot Water |
|
|
| Low System Pressure |
|
|
| Boiler Making Unusual Noises |
|
|
| Error Code Displayed |
|
|
8. Technical Specifications
| Specification | Value |
|---|---|
| Manufacturer | Immergas |
| Model | Victrix Zeus Superior ErP 32 kW |
| Product Dimensions (L x W x H) | 40 x 30 x 76 cm |
| Weight | 72.8 Grams (Note: This weight is unusually low for a boiler and may refer to a component or packaging. Actual boiler weight will be significantly higher.) |
| Reference Number | 3025454 |
| ASIN | B01E05I2E6 |
| Fuel Type | Methane Gas |
| Installation | Indoor / Partially Protected Outdoor |
| Electrical Protection | IPX5D |
| Integrated Tank Capacity | 54 Liters (Stainless Steel) |
| Anti-freeze Protection | Standard, down to -5 °C |
| Batteries Required | No |
9. Warranty Information
Specific warranty terms and conditions for the Immergas Victrix Zeus Superior ErP 32 kW boiler are provided by the manufacturer at the time of purchase. Please refer to the warranty card or documentation included with your product for details on coverage, duration, and claims procedures.
It is important to retain your proof of purchase and ensure that installation and annual servicing are carried out by qualified professionals to maintain warranty validity.
10. Customer Support
For technical assistance, spare parts, or service requests, please contact your authorized Immergas dealer or a qualified heating engineer. When contacting support, please have the following information ready:
- Model: Immergas Victrix Zeus Superior ErP 32 kW
- Reference Number: 3025454
- Date of Installation
- Description of the issue or error code displayed
You can find contact information for Immergas or authorized service partners on the manufacturer's official website or through your installer.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.