Model: HD200VP-UM
The AmScope HD200VP-UM is a versatile 1080p HDMI digital camera designed for both standalone and PC-based imaging applications. It delivers high-definition video at up to 60 frames per second (fps) and captures 2-megapixel still images. Featuring an industry-standard C-mount design, this camera can be easily integrated with various microscopes and optical systems. It offers flexible operation, allowing direct connection to an HDMI monitor for live viewing and recording to an SD card, or connection to a computer via USB for advanced software control and image processing.
Please verify that all items listed below are included in your package:
Before operating your AmScope HD200VP-UM camera, ensure all necessary connections are made securely.

Figure 1: AmScope HD200VP-UM Digital Camera showing its compact design and various ports.
The HD200VP-UM camera features an industry-standard C-mount for attachment to microscopes or other optical systems.

Figure 2: Close-up view of the AmScope HD200VP-UM C-mount, ready for attachment to a microscope.
To attach the camera to your microscope:
When connected to an HDMI monitor, the camera operates as a standalone imaging system:
When connected to a computer via USB, the camera can be controlled using the included software:
The included software offers different functionalities based on your operating system:
Proper care and maintenance will ensure the longevity and optimal performance of your AmScope HD200VP-UM camera.
If you encounter issues with your camera, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No image on HDMI monitor | HDMI cable loose or faulty; Monitor input not selected; Camera not powered on. | Check HDMI cable connection; Ensure monitor is set to correct HDMI input; Verify power adapter is connected and camera is on. |
| Camera not recognized by PC | USB cable loose or faulty; Software not installed correctly; Driver issue. | Check USB cable connection; Reinstall software and drivers from CD or AmScope website; Try a different USB port. |
| Cannot record to SD card | SD card not inserted correctly; SD card full or corrupted; SD card locked. | Reinsert SD card; Delete old files or use a new SD card; Unlock the SD card (physical switch). |
| Image is blurry or out of focus | Microscope focus not adjusted; C-mount not securely attached; Lens dirty. | Adjust microscope's fine and coarse focus; Ensure C-mount is tightened; Clean the camera lens. |
| Poor image quality (color/exposure) | Incorrect white balance or exposure settings. | Adjust white balance and exposure settings via the on-screen menu (HDMI) or software (PC). |
| Feature | Specification |
|---|---|
| Model | HD200VP-UM |
| Sensor Model | IMX236 (color) |
| Sensor Type | CMOS |
| Active Pixels | 2.07M (1920 x 1080) |
| Pixel Size | 2.8µm x 2.8µm |
| Optical Format | 1/2.8" |
| Shutter | Electronic Rolling Shutter |
| Sensitivity | 510mV @ 1/30s (f/5.6) |
| Spectral Response | 380-650nm with IR-cut filter |
| Video Preview Resolution (HDMI) | 1920 x 1080 |
| Video Preview Framerate (HDMI) | 60fps |
| Video Capture Resolution | 1920 x 1080 |
| Video Capture Framerate (SecureDigital) | 25fps |
| Video Capture Framerate (USB) | 30fps max |
| Photo Capture Resolution | 1920 x 1080 |
| Internal Photo Capture Format | JPG |
| Recording Media | SecureDigital card |
| Connectivity | HDMI, USB 2.0 |
| Lens-mount | C-mount |
| Power | 12VDC 1A |
| Dimensions | 78mm x 65mm x 88mm |
| Operating Temperature | -10-50°C |
| Operating Humidity | 30-80% |
| OS Requirements (Windows) | XP/Vista/7/8/10 (32/64 bit) |
| OS Requirements (Mac) | OS 10.8+ |
| OS Requirements (Linux) | Kernel 3.13+ |
| Hardware Requirements | Intel Core2 2.8GHz or comparable, 4GB RAM |
AmScope products are designed for quality and reliability. For specific warranty details, please refer to the warranty information included with your product packaging or visit the official AmScope website. Warranty terms typically cover manufacturing defects for a specified period from the date of purchase.
For technical support, troubleshooting assistance, or inquiries regarding parts and accessories, please contact AmScope customer service. Contact information can usually be found on the AmScope website or in your product documentation. When contacting support, please have your product model number (HD200VP-UM) and purchase information ready.
Note: No official product videos from the seller were found in the provided data.
![]() |
AmScope 150 Series Microscope User Manual This user manual provides comprehensive guidance for the AmScope 150 Series microscopes, including setup, operation, specifications, and troubleshooting. Learn to use your AmScope microscope effectively. |
![]() |
AmScope 150 Series Microscope User Manual Comprehensive user manual for the AmScope 150 Series microscope, detailing setup, operation, specifications, parts, and troubleshooting for optimal use. |
![]() |
AmScope 490 Series Compound Microscope Operator's Manual This operator's manual provides comprehensive instructions for the AmScope 490 Series Compound Microscope, covering setup, operation, maintenance, and troubleshooting for optimal use. |
![]() |
AmScope PM240 Series Stereo Microscope User Manual User manual for the AmScope PM240 Series stereo microscopes, covering setup, operation, specifications, and troubleshooting for binocular and trinocular models. |
![]() |
AmScope 120 Series Microscope User Manual Comprehensive user manual for the AmScope 120 Series microscopes, covering setup, operation, specifications, and troubleshooting for models like B120 and T120. |
![]() |
AmScope 490 Series Compound Microscope Operator's Manual | User Guide This operator's manual provides comprehensive instructions for the AmScope 490 Series Compound Microscope, covering setup, operation, maintenance, troubleshooting, and specifications. Learn to use your AmScope microscope effectively with this detailed guide. |