INIM Electronics IVY-B

INIM IVY-B Self-Powered Outdoor Siren User Manual

Model: IVY-B

1. Introduction

The INIM IVY-B is a self-powered outdoor siren designed for security systems. It features an I-BUS interface for seamless integration and offers a powerful sound output of 103 dB(A) at 3 meters. With an IP34 rating, it is suitable for outdoor environments. Parameters such as sound type and volume can be programmed via SmartLeague software, adapting to specific event requirements. The siren also includes an LED indicator for visual status. This product is certified CEI79-2 IMQ, ensuring reliability and compliance with safety standards.

2. Safety Information

  • Read all instructions carefully before installation and operation.
  • Installation should be performed by qualified personnel in accordance with local electrical codes and regulations.
  • Ensure the power supply is disconnected before performing any installation or maintenance.
  • Do not expose the siren to extreme temperatures or direct water jets beyond its IP34 rating.
  • The siren produces high sound levels. Avoid prolonged exposure to prevent hearing damage.
  • Use only recommended battery types for replacement to ensure proper operation and safety.

3. Product Overview

The INIM IVY-B siren is designed for robust outdoor performance. Key features include:

  • Self-Powered Operation: Ensures functionality even during power outages.
  • I-BUS Interface: For integration with compatible INIM alarm systems.
  • High Sound Output: 103 dB(A) at 3 meters for effective deterrence.
  • Weather Resistance: IP34 rating protects against dust and splashing water.
  • Programmable Parameters: Customize sound type and volume via SmartLeague software.
  • LED Indicator: Provides visual status feedback.
  • Certification: CEI79-2 IMQ certified for quality and safety.

3.1. Components

The IVY-B siren unit typically includes:

  • Siren housing with integrated electronics.
  • Mounting bracket (usually included).
  • Battery compartment (batteries sold separately).
  • LED indicator light.
INIM IVY-B Self-Powered Outdoor Siren, front view showing the white housing and sound output grille.

Figure 1: Front view of the INIM IVY-B Self-Powered Outdoor Siren. The image displays the compact white housing with a visible sound output grille and the INIM logo.

4. Setup

4.1. Mounting Location

Choose a suitable outdoor location that is:

  • Visible and audible from key areas.
  • Protected from direct physical impact.
  • Accessible for maintenance but difficult for unauthorized tampering.
  • Within range of the I-BUS wiring.

4.2. Physical Installation

  1. Secure the mounting bracket to a sturdy surface using appropriate screws and anchors (not supplied).
  2. Open the siren housing by unscrewing the retaining screws.
  3. Route the I-BUS wiring through the designated entry point.
  4. Connect the I-BUS wires to the terminals as indicated in the wiring diagram (refer to the system's main control panel manual for specific I-BUS connection details).
  5. Install the required self-powered battery (e.g., 12V rechargeable battery, not included) into the battery compartment, ensuring correct polarity.
  6. Close the siren housing and secure it to the mounting bracket.

4.3. Initial Configuration (SmartLeague)

The IVY-B siren's operational parameters, such as sound patterns, volume levels, and event-specific responses, are configured using the INIM SmartLeague software. Connect your alarm system's control panel to a computer running SmartLeague and follow the software's instructions to detect and configure the IVY-B siren on the I-BUS.

  • Ensure the siren is properly connected to the I-BUS.
  • Launch SmartLeague software on your computer.
  • Access the device configuration section and locate the IVY-B siren.
  • Adjust settings such as siren duration, sound type, and volume as required for your security system.
  • Save and upload the configuration to the control panel.

5. Operating Instructions

Once installed and configured, the INIM IVY-B siren operates automatically in conjunction with your INIM alarm system. It will activate based on the events and parameters set within the SmartLeague software.

5.1. Siren Activation

The siren will activate when an alarm event is triggered by the connected INIM control panel. The specific sound pattern and duration will correspond to the configuration programmed via SmartLeague.

5.2. LED Indicator

The integrated LED indicator provides visual feedback on the siren's status. Refer to your INIM control panel manual or SmartLeague documentation for a detailed explanation of LED patterns and their meanings (e.g., armed status, alarm, fault). Typically, a steady light might indicate armed status, while flashing lights could indicate an alarm or a system fault.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your IVY-B siren.

6.1. Cleaning

Periodically clean the exterior of the siren with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no water enters the internal components.

6.2. Battery Replacement

As a self-powered unit, the IVY-B relies on a rechargeable battery. The lifespan of the battery depends on usage and environmental conditions. If the system indicates a low battery fault for the siren, or if the siren fails to operate during a power outage, the battery may need replacement.

  • Disconnect Power: Ensure the main power to the alarm system is disconnected before opening the siren.
  • Open Housing: Carefully open the siren housing.
  • Replace Battery: Disconnect the old battery and replace it with a new, compatible rechargeable battery of the same type and voltage. Observe correct polarity.
  • Secure Housing: Close and secure the siren housing.
  • Test: Reconnect power and test the siren's operation.

Note: Dispose of old batteries according to local regulations.

6.3. System Checks

Regularly test your entire alarm system, including the siren, to ensure all components are functioning correctly. Refer to your alarm system's manual for recommended testing procedures.

7. Troubleshooting

ProblemPossible CauseSolution
Siren does not sound during alarm.
  • No power to siren.
  • Battery discharged or faulty.
  • Incorrect wiring.
  • Siren not configured in SmartLeague.
  • Faulty siren unit.
  • Check power supply to the control panel.
  • Check and replace siren battery if necessary.
  • Verify I-BUS wiring connections.
  • Confirm siren configuration in SmartLeague.
  • Contact technical support if unit is faulty.
LED indicator not working.
  • No power.
  • LED fault.
  • Check power and battery.
  • Contact technical support.
Siren sounds continuously or unexpectedly.
  • System fault.
  • Incorrect configuration.
  • Tamper switch activated.
  • Check alarm system status.
  • Review SmartLeague configuration.
  • Ensure siren housing is securely closed.

8. Specifications

  • Model: IVY-B
  • Sound Level: 103 dB(A) at 3 meters
  • Max Range: 3 Meters (for sound measurement)
  • IP Rating: IP34 (Protection against solid objects over 2.5mm and splashing water)
  • Interface: I-BUS
  • Power Source: Self-powered (requires rechargeable battery, not included)
  • Configuration Method: SmartLeague software
  • Dimensions (approx.): 30 x 20 x 10 cm (11.8 x 7.9 x 3.9 inches)
  • Weight (approx.): 2.25 kg (4.96 lbs)
  • Certification: CEI79-2 IMQ
  • Compatible Devices (System Integration): Smartphone, tablet, Smart Home Hub, IoT Devices (via INIM control panel)

9. Warranty and Support

INIM Electronics products are manufactured to high standards. For specific warranty terms and conditions, please refer to the documentation provided with your INIM control panel or contact your authorized INIM dealer or installer.

For technical assistance, troubleshooting beyond this manual, or spare parts inquiries, please contact your INIM product supplier or a certified INIM technical support professional. Information regarding spare parts availability is not provided in this document.

© 2024 INIM Electronics. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.