Gallagher 13053

Gallagher W310 v2 Automatic Weigh Scale User Manual

Model: 13053 | Brand: Gallagher

Introduction

The Gallagher W310 v2 Automatic Weigh Scale is an entry-level device designed for efficient and accurate livestock weighing. It features basic two-way drafting capability and seamless integration with the HR5 Hand Held EID Tag Reader. This manual provides comprehensive instructions for setting up, operating, and maintaining your W310 v2 weigh scale to ensure optimal performance and longevity.

Gallagher W310 v2 Automatic Weigh Scale

Figure 1: The Gallagher W310 v2 Automatic Weigh Scale, shown in its open position, displaying the screen and control buttons.

Key Features:

Setup and Installation

Proper setup is crucial for accurate and reliable operation of your Gallagher W310 v2 Weigh Scale. Follow these steps carefully:

  1. Unpacking: Carefully remove the weigh scale from its packaging. Inspect for any signs of damage. Retain packaging for future transport or storage.
  2. Charging the Battery: The W310 v2 has an internal rechargeable battery. Before first use, fully charge the unit using the provided AC adapter. Connect the adapter to the charging port on the scale and plug it into a suitable power outlet. The charge indicator on the display will show charging status.
  3. Connecting Load Bars: The W310 v2 is designed for use with Gallagher load bars (sold separately). Connect the load bar cables to the appropriate ports on the weigh scale. Ensure connections are secure.
  4. Mounting the Scale: Mount the weigh scale in a secure, stable location, typically near the weighing platform or crush. Ensure it is protected from direct impact and excessive moisture, although it features a water-resistant case.
  5. Initial Power On: Press and hold the power button to turn on the scale. The display will illuminate, and the system will perform a self-check.
  6. Connecting to External Devices (Optional):
    • HR5 Hand Held EID Tag Reader: To connect via Bluetooth, ensure the Bluetooth adapter is powered from the weigh scale. Follow the pairing instructions for your HR5 reader to establish a connection.
    • Computer/Printer: Use the inbuilt communication port (serial or USB, depending on model/adapter) to connect to a computer or printer for data transfer. Refer to your computer's or printer's manual for specific connection details.
Gallagher W310 v2 Weigh Scale installed in a livestock handling system

Figure 2: The Gallagher W310 v2 Weigh Scale mounted and in operation within a livestock handling system, demonstrating a typical installation.

Operating Instructions

The W310 v2 offers multiple weighing modes to suit different operational needs. Familiarize yourself with the controls and modes for efficient weighing.

Controls Overview:

Weighing Modes:

Rotate the selector knob to choose your desired weighing mode:

  1. Auto-weighing Mode:

    In this mode, the animal's weight locks automatically once stable, allowing for fast, hands-free weighing. This is ideal for high-throughput operations.

    • Ensure the scale is zeroed before an animal enters the platform.
    • Once the animal is on the platform, the scale will detect its presence and automatically lock onto a stable weight.
    • The locked weight will be displayed and can be recorded or sent to connected devices.
  2. Manual Weighing Mode:

    This mode gives the operator full control over the weighing cycle. The weight is recorded only when the WEIGH key is pressed.

    • Place the animal on the platform.
    • Wait for the animal to settle.
    • Press the WEIGH key to capture and record the weight.
  3. Fine Weighing Mode:

    Designed for small load weighing, this mode operates with no zero tracking for greater accuracy. It is suitable for precise measurements where minimal movement is expected.

    • Ensure the platform is clear and stable.
    • Place the item to be weighed carefully on the platform.
    • The scale will display the precise weight.

Data Management:

Gallagher W310 v2 Weigh Scale with feature callouts

Figure 3: Detailed view of the Gallagher W310 v2 Weigh Scale highlighting its key features, including built-in Bluetooth connectivity, multiple weighing modes, and the large display.

Maintenance

Regular maintenance ensures the longevity and accuracy of your Gallagher W310 v2 Weigh Scale.

Troubleshooting

This section provides solutions to common issues you might encounter with your W310 v2 Weigh Scale.

ProblemPossible CauseSolution
Scale does not turn on.Battery is fully discharged or faulty.Connect the AC adapter and charge the unit. If it still doesn't turn on, the battery may need replacement or contact support.
Inaccurate weight readings.Load bars not properly connected or damaged; scale not zeroed; unstable weighing platform.Ensure load bars are securely connected. Press the ZERO key before weighing. Verify the weighing platform is stable and level.
Cannot connect to HR5 Reader via Bluetooth.Bluetooth adapter not powered; incorrect pairing procedure; interference.Ensure the Bluetooth adapter is powered. Re-attempt pairing following instructions for both devices. Reduce interference by moving closer to the HR5 reader.
Display is dim or flickering.Low battery; extreme temperatures.Recharge the battery. Operate the scale within its specified temperature range.

If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact Gallagher customer support.

Specifications

FeatureDetail
ManufacturerGallagher
Part Number13053
Product Dimensions23.5 x 21.5 x 9.5 cm
Item Weight3.4 kg
ColourOrange
Display StyleLCD
Special FeaturesBacklit Display, Internal Rechargeable Battery, Bluetooth Connectivity (via adapter)
Power SourceInternal Rechargeable Battery / AC Adapter
First Available Date11 February 2020

Warranty and Support

The Gallagher W310 v2 Automatic Weigh Scale comes with a one-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.

For warranty claims, technical support, or further assistance, please contact Gallagher customer service. You can typically find contact information on the official Gallagher website or through your local distributor.

Please have your product model number (13053) and proof of purchase ready when contacting support.