Pedrollo 4PDm/0,75

Pedrollo 4-inch Submersible Borehole Rewindable Oil Motor

Model: 4PDm/0,75

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pedrollo 4-inch Submersible Borehole Rewindable Oil Motor, model 4PDm/0,75. Please read these instructions carefully before installation and use to ensure proper functioning and to prevent damage or injury. Keep this manual for future reference.

2. Product Overview and Technical Characteristics

The Pedrollo 4PDm/0,75 is a 4-inch submersible oil-filled motor designed for borehole applications. It features robust construction and specific technical attributes for reliable performance.

Pedrollo 4PDm/0,75 Submersible Motor

Figure 1: Pedrollo 4PDm/0,75 Submersible Motor. This image displays the overall design of the 4-inch submersible motor, highlighting its compact and cylindrical form factor suitable for borehole installation.

Key Technical Characteristics:

  • Motor Type: 4-inch submersible oil-filled motor.
  • Motor Sleeve: Constructed from stainless steel AISI 316 for durability and corrosion resistance.
  • Shaft Material: Made of "DUPLEX" stainless steel, specifically for models from 3 kW to 7.5 kW, ensuring high strength.
  • Sealing: Equipped with a high-quality mechanical seal to prevent water ingress.

3. Construction and Safety Standards

The motor is built to high standards, ensuring safety and longevity in demanding environments.

  • Motor Design: Rewindable submersible motor, filled with vegetable-type oil.
  • Flange Coupling: Dimensions comply with NEMA standards for broad compatibility.
  • Power Cable:
    • 1.7 meters for powers ranging from 0.37 kW to 3 kW.
    • 2.7 meters for powers ranging from 4 kW to 7.5 kW.
  • Single-Phase Versions: Include a capacitor within the packaging for immediate use.
  • Certifications: Complies with EN 60034-1, IEC 60034-1, and CEI 2-3 standards, indicated by the CE mark.

4. Electric Motor Specifications

  • Motor Type: 2-pole electric motor.
  • Frequency: 50 Hz (nominal speed ~2900 rpm).
  • Voltage Options:
    • Single-phase: 230 V
    • Three-phase: 400 V
  • Insulation Class: F class.
  • Protection Rating: IP 68, ensuring protection against dust and continuous immersion in water.

5. Application Limits

To ensure optimal performance and longevity, adhere to the following application limits:

  • Maximum Liquid Temperature: +35 °C.
  • Maximum Immersion Depth: 100 meters.
  • Starts Per Hour: Up to 20 at regular intervals.
  • Minimum Flow Rate for Motor Cooling: 8 cm/s.
  • Service Type: Continuous service S1.

6. Performance Data

Refer to the tables below for detailed performance specifications for single-phase and three-phase versions of the Pedrollo 4PDm motor series.

Single-Phase Versions (230 V / 50 Hz)

MODELRated power P2nStarting current ratio Istart/InPower factor cos φCapacitor (μF)hWeight
kWHp1/minmmkg
4PDm/0.500.370.5028003.30.86203116.5
4PDm/0.750.550.7528303.50.89253317.2
4PDm/10.75128253.20.91353568.5
4PDm/1.51.11.528403.20.934038610.2
4PDm/21.5228453.30.936043611.7
4PDm/32.2328303.10.947548114.9

Three-Phase Versions (400 V / 50 Hz)

MODELRated power P2nStarting current ratio Istart/InPower factor cos φhWeight
kWHp1/minmmkg
4PD/0.500.370.5028353.20.823116.5
4PD/0.750.550.7528353.80.833317.2
4PD/10.75128353.80.713568.5
4PD/1.51.11.528354.40.793719.4
4PD/21.5228353.80.8638610.2
4PD/32.2328356.50.7343611.7
4PD/43428405.40.7950515.0
4PD/5.545.528355.40.7761020.1
4PD/7.55.57.528305.50.8770024.7
4PD/107.51028405.40.7680029.0

7. Absorption Data

The following tables detail the current absorption for both single-phase and three-phase motor models.

Single-Phase Versions (230 V)

MODELVOLTAGE (single-phase)
230 V
4PDm/0.503.4 A
4PDm/0.754.7 A
4PDm/15.9 A
4PDm/1.58.3 A
4PDm/210.7 A
4PDm/315.2 A

Three-Phase Versions (400 V)

MODELVOLTAGE (three-phase)
230 V400 V
4PD/0.502.2 A1.8 A
4PD/0.753.4 A2.0 A
4PD/14.1 A2.4 A
4PD/1.55.9 A3.4 A
4PD/28.1 A4.7 A
4PD/310.6 A6.1 A
4PD/413.4 A7.7 A
4PD/5.515.4 A8.9 A
4PD/7.522.7 A11.2 A
4PD/10-16.4 A

8. Installation and Setup

Proper installation is crucial for the motor's performance and longevity. It is recommended that installation be performed by qualified personnel.

  1. Pre-Installation Check: Verify that the motor and all components are free from damage. Ensure the power supply matches the motor's voltage requirements (230V single-phase or 400V three-phase).
  2. Cable Connection: Connect the power cable securely, ensuring watertight seals. For single-phase models, integrate the provided capacitor as per wiring diagrams (not included in this general manual, refer to product-specific wiring instructions).
  3. Flange Coupling: Securely attach the motor to the pump using NEMA-compliant flange connections.
  4. Lowering into Borehole: Carefully lower the motor and pump assembly into the borehole, ensuring it remains vertical and does not snag on the casing. Maintain the minimum flow rate for motor cooling (8 cm/s) around the motor.
  5. Immersion Depth: Do not exceed the maximum immersion limit of 100 meters. Ensure the motor is fully submerged during operation.
  6. Electrical Connection: Connect the power cable to a suitable control panel with appropriate overload protection. Ensure proper grounding.

9. Operating Instructions

Once installed, the motor is designed for continuous service (S1) within its specified application limits.

  • Initial Start-up: After installation, perform a brief test run to ensure correct rotation and operation. Monitor current draw.
  • Continuous Operation: The motor is designed for continuous duty. Avoid frequent starts and stops; limit to 20 starts per hour at regular intervals.
  • Temperature Monitoring: Ensure the liquid temperature does not exceed +35 °C to prevent overheating.
  • Dry Running: Never operate the motor without being fully submerged in water, as this will cause severe damage.

10. Maintenance

The Pedrollo submersible motor is designed for minimal maintenance. However, periodic checks are recommended.

  • Regular Inspection: Periodically check the control panel for proper functioning of protection devices.
  • Cable Integrity: Inspect the power cable for any signs of wear or damage during any retrieval of the pump.
  • Oil Check: The motor is oil-filled and sealed. No user-serviceable oil changes are required. If oil leakage is suspected, contact qualified service personnel.
  • Cleaning: If the pump assembly is retrieved, clean any accumulated debris from the motor's exterior to ensure efficient cooling.

11. Troubleshooting

This section provides general guidance for common issues. For complex problems, contact a qualified technician.

  • Motor Does Not Start:
    • Check power supply and circuit breakers.
    • Verify electrical connections and ensure the capacitor (for single-phase) is correctly wired.
    • Check for tripped overload protection.
  • Motor Runs But No Water/Low Flow:
    • Ensure the pump is properly connected to the motor and is not blocked.
    • Check water level in the borehole; ensure motor is fully submerged.
    • Inspect piping for blockages or leaks.
  • Motor Overheats/Trips Overload:
    • Verify the liquid temperature is within limits (+35 °C max).
    • Ensure sufficient water flow for motor cooling (min 8 cm/s).
    • Check for excessive starts per hour.
    • Inspect for mechanical binding in the pump or motor.

12. General Specifications

  • Brand: Pedrollo
  • Model Number: 4ZPC07A1 (Internal reference, corresponds to 4PDm/0,75)
  • Product Weight: 7.2 kg
  • Material: Stainless Steel
  • Maximum Lifting Height: 2.7 Meters (Note: This value seems low for a borehole pump motor and might refer to a specific pump head, not the motor's capability. Always refer to the pump's specifications for actual head.)

13. Warranty and Support

Pedrollo products are manufactured to high-quality standards. For warranty information, please refer to the warranty card included with your purchase or contact your authorized Pedrollo dealer. For technical support or service, please contact your local Pedrollo service center or the retailer from whom you purchased the product.

Related Documents - 4PDm/0,75

Preview Pedrollo 6ST 6-Inch Stainless Steel Submersible Pumps | Datasheet
Explore the Pedrollo 6ST series of 6-inch stainless steel submersible pumps. This datasheet provides comprehensive details on performance ranges, technical specifications, materials, dimensions, and application suitability for industrial, civil, and agricultural uses.
Preview Pompe Elettrosommergibili Pedrollo: DAVIS, 4-BLOCK, SALI, PRO 100AR - Istruzioni d'Uso
Guida completa alle pompe elettrosommergibili Pedrollo, inclusi i modelli DAVIS, 4-BLOCK, SALI, PRO 100AR, 3SR, 4SR, 4HR, 6SR, 6ST, 6HR, 4PD, 4PS, 6PD, 6PSR. Fornisce dettagli su installazione, uso sicuro, limiti operativi e manutenzione per un efficiente approvvigionamento idrico.
Preview Pedrollo UP Series Multicellular Submersible Pumps - Technical Specifications and Performance
Detailed technical specifications, performance curves, installation guidelines, and construction features for the Pedrollo UP series of multicellular submersible pumps, designed for clean water applications in domestic, civil, and agricultural sectors.
Preview Pedrollo FLUID SOLAR 4" Solar Submersible Pumps | Technical Datasheet
Explore the Pedrollo FLUID SOLAR series of 4-inch solar submersible pumps. Engineered for efficient water extraction from wells using photovoltaic power, these pumps feature high-efficiency motors with integrated electronic control for optimal performance in varying solar conditions.
Preview Pedrollo TRITUS Submersible Pumps with Grinder: Technical Specifications and Applications
Explore the technical specifications, performance curves, dimensions, and installation guidelines for Pedrollo TRITUS submersible pumps with grinders. Ideal for domestic and civil wastewater management.
Preview Pedrollo TOP-FLOOR Submersible Drainage Pumps: Performance and Specifications
Explore the Pedrollo TOP-FLOOR series of submersible drainage pumps, designed for clear water applications. Learn about their performance range, application limits, construction details, and installation suitability for domestic emergencies.