This manual provides comprehensive instructions for the installation, operation, and maintenance of your CHACON Motion Detector, model 34310. This device is designed to automatically switch lighting on and off based on detected movement, contributing to energy savings and convenience in indoor environments. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Safety Instructions

Always adhere to the following safety guidelines to prevent injury or damage to the device:

  • Installation must be performed by a qualified electrician or competent person in accordance with local electrical codes and regulations.
  • Disconnect the main power supply before commencing any installation, wiring, or maintenance work.
  • Do not exceed the maximum load capacity of 500 watts for incandescent lamps.
  • Ensure the device is connected to a 230V ~ 50Hz power supply.
  • Do not attempt to disassemble or modify the device. There are no user-serviceable parts inside.
  • Keep the device away from water, moisture, and extreme temperatures.

3. Product Overview

The CHACON 34310 Motion Detector integrates a Passive Infrared (PIR) sensor to detect movement within its coverage area. It features a simple interface for mode selection.

CHACON 34310 Motion Detector front view with sensor and ON/AUTO/OFF switch

This image displays the front panel of the CHACON 34310 Motion Detector. It features a white rectangular housing with a translucent, ribbed PIR sensor window at the top. Below the sensor, there is a small white switch with 'ON', 'AUTO', and 'OFF' labels, indicating the operating modes. The overall design is simple and functional, suitable for indoor wall mounting.

Key Components:

  • PIR Sensor Window: Detects infrared radiation emitted by moving objects.
  • Mode Selector Switch: Allows selection between ON, AUTO, and OFF modes.
  • Adjustment Dials (Internal/Concealed): Used to set time delay and light sensitivity. These are typically accessed during installation or setup.

4. Setup and Installation

Careful planning and execution are essential for optimal performance.

4.1 Pre-installation Considerations

  • Power Supply: Ensure a stable 230V ~ 50Hz power source is available at the installation location.
  • Load Compatibility: The detector supports a maximum load of 500 watts for incandescent lamps. Verify your lighting fixture's wattage.
  • Mounting Type: Designed for indoor mounting.

4.2 Placement Guidelines

Proper placement is critical for effective motion detection and to avoid false triggers.

  • Coverage Area: The detector has a 120° detection angle and a maximum range of 8 meters. Position it to cover the desired area effectively.
  • Avoid Obstructions: Ensure the sensor has a clear line of sight to the area it monitors. Walls, furniture, or large objects can block detection.
  • Minimize False Triggers:
    • Do not install near heat sources such as heating vents, radiators, or direct sunlight, as these can cause false activations.
    • Avoid aiming the sensor directly at windows where moving vehicles or pedestrians outside could trigger it.
    • Keep away from areas with strong air currents (e.g., near fans or air conditioning units) that might cause temperature fluctuations.

4.3 Wiring Instructions

WARNING: Ensure power is disconnected at the main circuit breaker before proceeding with wiring.

  1. Carefully open the detector housing to access the wiring terminals.
  2. Connect the Live (L) wire from the power supply to the Live input terminal on the detector.
  3. Connect the Neutral (N) wire from the power supply to the Neutral input terminal on the detector.
  4. Connect the Switched Live (L') output terminal of the detector to the Live input of your lighting fixture.
  5. Connect the Neutral wire from the lighting fixture to the Neutral wire of the main power supply (or to the Neutral terminal on the detector if provided for load).
  6. Secure all connections firmly and ensure no bare wires are exposed.
  7. Close the detector housing and mount it securely in the chosen location.

5. Operating Instructions

Once installed, the CHACON 34310 Motion Detector can be configured and operated using its mode selector switch and internal adjustment dials.

5.1 Mode Selector Switch

The front-facing switch allows you to select the operating mode:

  • ON: The connected light will remain continuously on, regardless of motion detection or ambient light levels.
  • AUTO: The detector will operate in automatic mode. The light will turn on when motion is detected and ambient light conditions meet the set sensitivity, and will turn off after the set time delay.
  • OFF: The connected light will remain continuously off, regardless of motion detection.

5.2 Adjustment Dials (Time and Light Sensitivity)

These dials are typically located behind the front cover or on the side of the unit and are used to fine-tune the detector's behavior. Adjust them using a small screwdriver if necessary.

  • Time Delay (Durable): This dial controls how long the light remains on after the last detected motion. It is adjustable from approximately 10 seconds to 4 minutes. Turn clockwise to increase the duration, counter-clockwise to decrease.
  • Light Sensitivity (Candle Power Command): This dial determines the ambient light level at which the detector will become active. It can be adjusted from full darkness (light will activate even in bright conditions) to daylight (light will only activate in low light conditions). Turn clockwise for higher sensitivity (activates in brighter conditions), counter-clockwise for lower sensitivity (activates only in darker conditions).

6. Maintenance

The CHACON 34310 Motion Detector requires minimal maintenance.

  • Cleaning: Periodically wipe the sensor window and housing with a soft, dry cloth to remove dust and dirt. Do not use abrasive cleaners, solvents, or excessive moisture.
  • Inspection: Occasionally check for any visible damage to the housing or wiring. If damage is found, disconnect power and consult a qualified electrician.
  • No User-Serviceable Parts: Do not attempt to open the unit for internal cleaning or repair.

7. Troubleshooting

If you experience issues with your motion detector, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Light does not turn on when motion is detected.
  • Power supply issue.
  • Light sensitivity set too low (daylight mode).
  • Time delay set to minimum.
  • Faulty wiring connection.
  • Bulb is burnt out.
  • Sensor obstructed.
  • Check power supply to the detector.
  • Adjust light sensitivity dial towards 'darker' setting.
  • Adjust time delay dial to a longer duration.
  • Verify all wiring connections are secure (with power off).
  • Replace the light bulb.
  • Clear any obstructions from the sensor's view.
Light stays on continuously or turns on randomly (false triggers).
  • Detector set to 'ON' mode.
  • Light sensitivity set too high.
  • Sensor detecting heat sources or air currents.
  • Movement outside the intended detection area.
  • Switch the mode selector to 'AUTO'.
  • Adjust light sensitivity dial towards 'daylight' setting.
  • Relocate the detector away from heat sources or drafts.
  • Re-aim the sensor or adjust its position to exclude unwanted areas.
Light turns off too quickly or too slowly.Time delay setting is incorrect.Adjust the time delay dial to the desired duration.
Light flickers when connected to the detector.
  • Incompatible bulb type (e.g., some LED bulbs).
  • Minimum load not met (less common for 500W max).
  • Faulty detector.
  • Try a different type of bulb, preferably an incandescent bulb as specified.
  • Consult a qualified electrician if the problem persists.

If these troubleshooting steps do not resolve the issue, contact a qualified electrician or the product retailer for further assistance.

8. Specifications

FeatureSpecification
BrandCHACON
Model Number34310
Power SourceMains Powered (230V ~ 50Hz)
Maximum Load500 watts (incandescent lamp)
Detection Angle120 degrees
Maximum Range8 meters
Time Delay AdjustmentApprox. 10 seconds to 4 minutes
Light Sensitivity AdjustmentStepless from daylight to full darkness
Mounting TypeIndoor mounting
MaterialPVC
ColorWhite
Product Dimensions12 x 6 x 16 cm
Item Weight0.14 Kilograms
Upper Temperature Rating75 Degrees Celsius

9. Warranty and Support

For information regarding the product warranty, please refer to the terms and conditions provided by your retailer at the time of purchase. For technical support or further assistance, please contact the CHACON customer service or your product retailer.

Ask a question about this manual