1. Introduction

This manual provides comprehensive instructions for the setup, operation, maintenance, and troubleshooting of the Cooper-Atkins 92010-K Blue2 Bluetooth Temperature Monitor. This device is designed for accurate temperature measurement and wireless data transmission to compatible mobile devices.

The 92010-K Blue2 kit includes the 20100-K Blue2 Instrument and the 51337-K DuraNeedle Direct Connect Probe. It utilizes Bluetooth Low Energy to transmit temperature readings wirelessly and is compatible with any interchangeable Type-K thermocouple temperature probe for various measurement applications (insertion, air, or surface temperature). The recorded data can be integrated into existing third-party applications.

Key features include auto-off and sleep mode timers, adjustable from 1 to 30 minutes in 1-minute increments, to conserve battery life.

2. Package Contents

Verify that all items are present in the package:

  • Cooper-Atkins 20100-K Blue2 Instrument
  • Cooper-Atkins 51337-K DuraNeedle Direct Connect Probe (1 ft. Probe Wire L)
  • 1 x CR123A Battery (pre-installed or included separately)
  • User Manual (this document)

3. Product Overview

Cooper-Atkins Blue2 Bluetooth Temperature Monitor with probe attached, front view.

Figure 3.1: Front view of the Cooper-Atkins Blue2 Bluetooth Temperature Monitor with the DuraNeedle probe connected. The device features a power button and Bluetooth logo on its face.

Cooper-Atkins Blue2 Bluetooth Temperature Monitor with probe attached, side view.

Figure 3.2: Side view of the Cooper-Atkins Blue2 Bluetooth Temperature Monitor, showing its compact design and the attached DuraNeedle probe.

The Cooper-Atkins Blue2 is a compact, handheld device designed for precise temperature measurement in various professional settings. It features a robust casing and a standard Type-K thermocouple input for versatile probe compatibility.

Key Components:

  • Main Unit: The core device housing the electronics, Bluetooth module, and battery compartment.
  • Power Button: Used to turn the device on/off and activate sleep mode.
  • Type-K Input Jack: Standard connector for Type-K thermocouple probes.
  • DuraNeedle Probe (51337-K): A durable, direct-connect probe included in the kit, suitable for insertion temperature measurements.
  • Bluetooth Indicator: A visual indicator (LED) for Bluetooth connection status.

4. Setup

4.1 Battery Installation

  1. Locate the battery compartment on the device.
  2. Open the compartment cover.
  3. Insert one CR123A battery, ensuring correct polarity (+/-).
  4. Close the battery compartment cover securely.

4.2 Probe Connection

  1. Align the Type-K connector of the DuraNeedle probe (or any compatible Type-K probe) with the input jack on the Blue2 instrument.
  2. Gently push the probe connector into the jack until it is firmly seated. Ensure a secure connection for accurate readings.

4.3 Initial Power On and Bluetooth Pairing

  1. Press and hold the power button on the Blue2 instrument until the device powers on.
  2. Ensure Bluetooth is enabled on your mobile device (smartphone or tablet).
  3. Open your preferred third-party temperature monitoring application that supports the Cooper-Atkins Blue2.
  4. Follow the application's instructions to search for and pair with the Blue2 device. The Bluetooth indicator on the Blue2 will typically change status (e.g., solid blue) once successfully paired.

5. Operating Instructions

5.1 Taking Temperature Readings

  1. Ensure the Blue2 instrument is powered on and successfully paired with your mobile device.
  2. Insert the probe into the substance or environment you wish to measure. For insertion probes, ensure the tip is fully immersed or inserted to the appropriate depth.
  3. Observe the temperature reading displayed on your mobile device's application. Allow a few seconds for the reading to stabilize.
Person holding Cooper-Atkins Blue2 temperature monitor, measuring temperature in a food buffet line.

Figure 5.1: The Blue2 monitor in use, demonstrating temperature measurement in a food service setting, such as a buffet line.

Person holding Cooper-Atkins Blue2 temperature monitor, measuring temperature of raw fish fillets.

Figure 5.2: The Blue2 monitor being used to check the temperature of raw fish fillets, highlighting its application in food safety.

5.2 Auto-Off and Sleep Mode Timers

The Blue2 instrument features adjustable auto-off and sleep mode timers to conserve battery life. These timers can be configured within your connected third-party application, typically ranging from 1 to 30 minutes in 1-minute increments. Refer to your application's settings for specific adjustment procedures.

5.3 Powering Off the Device

To manually power off the device, press and hold the power button until the device shuts down. The device will also power off automatically after the set auto-off timer duration if no activity is detected.

6. Maintenance

6.1 Cleaning

  • Wipe the instrument and probe with a damp cloth. For disinfection, use a mild, food-safe sanitizing solution.
  • Do not immerse the main instrument in water, although it has an IPX7 waterproof rating, it is best to avoid prolonged submersion. The probe can be cleaned thoroughly.
  • Ensure the device is dry before storage.

6.2 Battery Replacement

When the battery level is low (indicated by the mobile application or device behavior), replace the CR123A battery following the instructions in Section 4.1. Dispose of old batteries responsibly according to local regulations.

6.3 Storage

Store the Blue2 instrument and probe in a clean, dry place away from extreme temperatures and direct sunlight. Protect the probe tip from damage.

7. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.Dead or incorrectly installed battery.Replace the CR123A battery, ensuring correct polarity.
Cannot connect via Bluetooth.Bluetooth is off on mobile device; device out of range; pairing issue; interference.Ensure Bluetooth is on; move closer to the device (within 100 ft line-of-site); restart both devices; check for other Bluetooth devices causing interference.
Inaccurate temperature readings.Probe not fully inserted; damaged probe; incorrect probe type; calibration needed.Ensure probe is properly inserted; inspect probe for damage and replace if necessary; ensure it's a Type-K thermocouple; consult Cooper-Atkins for calibration services if suspected.
Data not appearing in third-party app.App not configured correctly; app compatibility issue.Verify app settings and permissions; ensure the app is compatible with Cooper-Atkins Blue2; update the app to the latest version.

8. Technical Specifications

FeatureSpecification
Model Number92010-K
Bluetooth Range100 ft (Line-of-Site)
Temperature Range-40 to 999 degrees F (-40 to 537 degrees C)
Thermometer Accuracy+/- 2 degrees F (+/- 1 degree C)
Waterproof RatingIPX7
Battery Life500 hours
Ambient Operating Range32 to 122 degrees F (0 to 50 degrees C)
Battery Type1 x CR123A (included)
Auto-Off/Sleep TimerAdjustable 1-30 minutes (1-minute increments)
MaterialMetal (for probe, main unit casing is likely durable plastic/composite)
Dimensions9 x 4.5 x 2.5 inches (Product)
Weight7.37 ounces

9. Warranty Information

Cooper-Atkins products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Cooper-Atkins website. Keep your purchase receipt as proof of purchase for any warranty claims.

Typical warranties cover defects in materials and workmanship under normal use. Damage resulting from misuse, unauthorized repairs, or accidents may not be covered.

10. Customer Support

For technical assistance, product inquiries, or service, please contact Cooper-Atkins customer support:

  • Website: www.cooper-atkins.com
  • Phone: Refer to the website for regional contact numbers.
  • Address: Cooper-Atkins Corporation, Middlefield, CT, USA.

When contacting support, please have your product model number (92010-K) and serial number (if applicable) ready.

© 2024 Cooper-Atkins Corporation. All rights reserved.