1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Air Vent Power Roof Ventilator, Model TRVAL61268. This power attic vent features a low-profile dome designed to be unobtrusive when installed on the roof. It is an efficient solution for attic ventilation, capable of replacing existing wind turbines or roof pots.
The ventilator is designed to move 1170 cubic feet of air per minute (CFM), effectively ventilating attics up to 1650 square feet. It includes an adjustable thermostat for optimal temperature control.
2. Safety Information
Please read and understand all safety instructions before installing or operating this product. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury.
- Electrical Safety: Ensure power is disconnected at the circuit breaker before any installation, maintenance, or repair. All electrical wiring must comply with local codes and ordinances and be performed by a qualified electrician.
- Fall Hazard: Installation on a roof involves working at heights. Use appropriate safety equipment, including harnesses and fall protection, and ensure stable footing.
- Moving Parts: Keep hands, hair, and loose clothing away from the fan blade during operation and when power is connected.
- Ventilation: Do not use this ventilator in areas where hazardous or explosive materials are present. Ensure adequate intake ventilation is provided in the attic space.
- Product Modification: Do not modify the ventilator or its components. Use only genuine replacement parts.
3. Package Contents
Verify that all components are present before beginning installation:
- Power Roof Ventilator Unit (with 14-1/2" diameter fan blade)
- Integrated Thermostat
- Motor
- Installation Hardware (screws, fasteners - may vary)
- User Manual (this document)

Image: Air Vent Power Roof Ventilator, Model TRVAL61268. This image shows the complete ventilator unit with its low-profile dome, designed for roof-mounted attic ventilation.
4. Installation and Setup
Proper installation is crucial for the performance and longevity of your ventilator. This unit is designed for flush mounting on the roof.
- Site Selection: Choose a location on the roof that allows for optimal airflow and is away from obstructions. The ventilator should be installed on the roof face slanting away from the front of your home for an unobtrusive appearance.
- Prepare Opening: Create a 14-1/2 inch diameter opening in the roof deck. Ensure the opening is clear of any structural elements.
- Intake Ventilation: Critical for proper operation, ensure your attic has a minimum of 562 square inches of net free intake area. Insufficient intake ventilation can lead to motor overheating and reduced performance.
- Mounting: Position the ventilator over the prepared opening. Secure the unit to the roof deck using appropriate fasteners, ensuring a watertight seal around the base. Follow roofing best practices for flashing and sealing.
- Electrical Connection: This is a corded electric unit. Connect the ventilator to a dedicated electrical circuit as per local electrical codes. Ensure the power source matches the ventilator's requirements (195 watts, 2.8 Amps). A qualified electrician should perform all electrical connections.
- Thermostat Adjustment: The integrated thermostat is adjustable from 60 to 120 degrees Fahrenheit. Set the thermostat to your desired attic temperature. The fan will activate when the attic temperature exceeds this setting and deactivate when it falls below.
5. Operation
Once properly installed and connected to power, the Air Vent Power Roof Ventilator operates automatically based on its thermostat setting.
- Automatic Operation: The fan will turn on when the attic temperature rises above the set thermostat point and will turn off when the temperature drops below it.
- Thermostat Setting: Adjust the thermostat dial to select the desired temperature range for attic ventilation. A common setting is between 90-100°F (32-38°C) to prevent excessive heat buildup.
- Airflow: The 6-bladed fan provides 1170 CFM of airflow, effectively removing hot, humid air from attics up to 1650 sq.ft.
6. Maintenance
Regular maintenance ensures optimal performance and extends the life of your ventilator.
- Annual Inspection: Annually inspect the ventilator for any debris, such as leaves or bird nests, that may obstruct airflow.
- Clean Fan Blades: With power disconnected, carefully clean any dust or grime from the fan blades to maintain efficiency.
- Check Wiring: Periodically inspect electrical connections for signs of wear or damage. Ensure all connections are secure.
- Dome Integrity: Check the metal dome for any damage, cracks, or loose fasteners that could compromise its weather resistance.
- Roof Seal: Inspect the seal around the base of the ventilator for any signs of deterioration or leaks. Re-seal as necessary.
7. Troubleshooting
If your ventilator is not operating as expected, refer to the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fan does not turn on. | No power; Thermostat set too high; Faulty motor/thermostat. | Check circuit breaker; Lower thermostat setting; Consult a qualified technician. |
| Fan runs continuously. | Thermostat set too low; Faulty thermostat. | Raise thermostat setting; Consult a qualified technician. |
| Low airflow. | Obstructed intake/exhaust; Dirty fan blades; Insufficient intake ventilation. | Clear obstructions; Clean fan blades; Ensure adequate attic intake. |
| Excessive noise/vibration. | Loose mounting; Debris in fan; Worn motor bearings. | Tighten mounting hardware; Clear debris; Consult a qualified technician. |
For issues not listed above or if solutions do not resolve the problem, contact customer support or a qualified professional.
8. Specifications
| Model Number | TRVAL61268 |
| Part Number | 53829 |
| Manufacturer | Air Vent Inc |
| Item Weight | 18.5 pounds |
| Product Dimensions | 26 x 9 x 26 inches |
| Material | Metal |
| Finish | Painted |
| Power Source | Corded Electric |
| Wattage | 195 watts |
| Air Flow Capacity | 1170 Cubic Feet Per Minute (CFM) |
| Ventilation Area | Up to 1650 sq.ft. |
| Mounting Type | Flush Mount |
| Special Features | Adjustable Thermostat (60 to 120 degrees F) |
| Included Components | Thermostat, Motor |
| Fan Blade Diameter | 14-1/2 inches |
| Required Net Free Intake Area | 562 sqin |
9. Warranty and Support
For warranty information, please refer to the documentation provided at the time of purchase or visit the official Air Vent website. Keep your proof of purchase for warranty claims.
If you require technical assistance, replacement parts, or have questions not covered in this manual, please contact Air Vent customer support. Contact details can typically be found on the manufacturer's website or product packaging.