This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Gree GDN30AI-K4EBB3G Dehumidifier. Please read these instructions thoroughly before using the appliance and retain them for future reference.
2. Safety Instructions
- Ensure the power supply voltage matches the rating label on the unit.
- Do not operate the dehumidifier with a damaged power cord or plug.
- Always place the unit on a stable, level surface to prevent water spillage.
- Maintain at least 20 cm (8 inches) clearance around the unit for proper airflow.
- Do not insert objects into the air inlet or outlet.
- Unplug the unit before cleaning or performing any maintenance.
- Keep the appliance away from heat sources and direct sunlight.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
3. Product Overview
Familiarize yourself with the components and control panel of your Gree GDN30AI-K4EBB3G Dehumidifier.

Figure 1: Top view of the Gree GDN30AI-K4EBB3G Dehumidifier showing the control panel and integrated handle. The control panel features a digital display for humidity, various indicator lights, and control buttons.
Control Panel Features:
- 1. ON/OFF Button: Press to turn the dehumidifier on or off.
- 2. Humidity Display: Digital display showing the current room humidity or the set humidity level.
- 3. Humidity Adjustment Buttons (+/-): Used to increase or decrease the desired humidity level.
- 4. Fan Speed Button: Cycles through fan speed settings: Low, Mid, High.
- 5. Timer Button: Activates or adjusts the timer for automatic on/off operation.
- 6. Power Indicator: Illuminates when the unit is powered on.
- 7. Bucket Full Indicator: Illuminates when the water collection bucket is full and needs emptying. The unit will automatically stop operating.
- 8. Continuous Mode Indicator: Illuminates when the dehumidifier is set to operate continuously, regardless of humidity level.
- 9. Filter Reset Button: Press after cleaning or replacing the air filter to reset the filter reminder.
4. Setup
4.1 Unpacking
- Carefully remove the dehumidifier from its packaging.
- Remove all packing materials, including any tape or protective films.
- Inspect the unit for any signs of damage during transit. If damaged, do not operate and contact your retailer.
4.2 Placement
- Place the dehumidifier on a firm, level surface that can support its weight when the water bucket is full.
- Ensure there is at least 20 cm (8 inches) of space on all sides of the unit for adequate air circulation.
- Avoid placing the unit near heat-generating appliances, in direct sunlight, or in areas exposed to freezing temperatures.
- For optimal performance, close all doors and windows in the room where the dehumidifier is operating.
4.3 Power Connection
Plug the power cord into a properly grounded electrical outlet. Ensure the outlet meets the electrical requirements specified in the 'Specifications' section of this manual.
4.4 Water Drainage Options
Your dehumidifier offers two methods for water removal:
- Manual Drainage (Water Bucket): The collected water accumulates in the internal water bucket. When the bucket is full, the unit will automatically shut off, and the 'Bucket Full' indicator will illuminate. Empty the bucket and reinsert it to resume operation.
- Continuous Drainage: For continuous operation without needing to empty the bucket, you can connect a drain hose (not included) to the continuous drain outlet on the back of the unit. Ensure the hose is sloped downwards to allow gravity drainage into a suitable floor drain or container.
5. Operating Instructions
5.1 Turning On/Off
Press the ON/OFF button to power the unit on or off. The Power indicator will light up when the unit is on.
5.2 Setting Desired Humidity Level
- With the unit on, the digital display will show the current room humidity.
- Press the + or - buttons to adjust the desired humidity level. The setting range is typically between 30% RH (Relative Humidity) and 80% RH.
- The unit will operate until the room humidity reaches the set level, then it will cycle off. It will restart automatically if the humidity rises above the set level.
5.3 Fan Speed Selection
Press the Fan Speed button to cycle through the available fan speeds: Low, Mid, and High. A higher fan speed will result in faster dehumidification.
5.4 Continuous Operation
To operate the dehumidifier continuously, bypassing the humidity setting, press the Continuous button (or cycle through modes until the Continuous indicator lights up, depending on the specific button layout). In this mode, the unit will run constantly until manually turned off or the bucket is full (if not using continuous drainage).
5.5 Timer Function
The timer function allows you to set a specific time for the unit to turn on or off automatically.
- Auto-Off Timer: With the unit running, press the Timer button and use the + or - buttons to set the desired number of hours (e.g., 1-24 hours) after which the unit will turn off.
- Auto-On Timer: With the unit off, press the Timer button and use the + or - buttons to set the desired number of hours after which the unit will turn on.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your dehumidifier.
6.1 Emptying the Water Bucket
- When the 'Bucket Full' indicator lights up, gently pull out the water bucket from the front of the unit.
- Carefully carry the bucket to a sink or drain and empty the collected water.
- Rinse the bucket with clean water periodically to prevent mold or mildew growth.
- Reinsert the empty bucket firmly into the unit. The dehumidifier will resume operation automatically.
6.2 Cleaning the Air Filter
The air filter should be cleaned every two weeks or more frequently depending on usage and air quality.
- Turn off and unplug the dehumidifier.
- Locate the air filter (usually at the back or side of the unit) and remove it.
- Wash the filter with warm, soapy water, or use a vacuum cleaner to remove dust and debris.
- Rinse thoroughly and allow the filter to air dry completely before reinserting it.
- Once the filter is reinstalled, plug in the unit and press the Filter Reset button to clear the filter reminder light.
6.3 Cleaning the Exterior
Wipe the exterior of the dehumidifier with a soft, damp cloth. Do not use harsh chemicals, abrasives, or solvents, as these can damage the surface.
6.4 Storage
If storing the unit for an extended period:
- Empty and clean the water bucket.
- Clean the air filter.
- Allow the unit to run for a few hours in a dry room to ensure the internal components are dry.
- Cover the unit with a plastic bag or cloth to protect it from dust.
- Store in a cool, dry place.
7. Troubleshooting
Before contacting customer service, please refer to the following troubleshooting guide for common issues.
| Problem | Possible Cause | Solution |
|---|---|---|
| Dehumidifier does not turn on. | No power supply. Power cord not securely plugged in. Bucket full or not properly inserted. | Check power outlet and circuit breaker. Ensure power cord is firmly connected. Empty and correctly reinsert the water bucket. |
| No water collected. | Room temperature too low. Humidity level already low. Air filter clogged. Continuous drainage hose improperly connected. | Dehumidifiers operate best above 5°C (41°F). Increase desired humidity setting or check room humidity. Clean the air filter. Ensure hose is properly connected and sloped downwards. |
| Unit runs continuously. | Set to Continuous mode. Desired humidity level set too low. Large room or high moisture load. | Turn off Continuous mode. Increase the desired humidity setting. Allow more time for dehumidification or consider a larger unit for the space. |
| Unusual noise. | Unit not on a level surface. Air filter clogged. Internal components loose. | Place on a firm, level surface. Clean the air filter. If noise persists, contact customer support. |
8. Specifications
| Feature | Specification |
|---|---|
| Model | GDN30AI-K4EBB3G |
| Dehumidification Capacity | 30 Liters/Day (at 30°C/80% RH) |
| Water Tank Capacity | 7.0 Liters (Max 8.3 Liters) |
| Noise Level | 55 dB(A) |
| Operating Temperature Range | 5°C – 35°C (41°F – 95°F) |
| Rated Voltage | 220-240 V |
| Frequency | 50 Hz |
| Rated Power | 500 Watts |
| Product Weight | 18.1 kg |
| Product Dimensions (H x W x D) | 611 x 383 x 298 mm |
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact your retailer/manufacturer directly. Ensure you have your model number (GDN30AI-K4EBB3G) and purchase date available when contacting support.