Introduction

This manual provides essential instructions for the safe installation, operation, and maintenance of your Everbilt 1/2 HP Submersible Sump Pump with Tether. Please read this manual thoroughly before installation and retain it for future reference. Proper installation and adherence to these guidelines will ensure optimal performance and longevity of the pump.

Important Safety Instructions

WARNING: Failure to follow these instructions may result in electric shock, fire, serious injury, or death.

Product Overview

The Everbilt 1/2 HP Submersible Sump Pump is designed for automatic operation in residential sump pits. It features a durable aluminum housing and a tethered float switch for reliable water removal.

Everbilt 1/2 HP Submersible Sump Pump with Tether

Figure 1: Everbilt 1/2 HP Submersible Sump Pump. This image shows the complete sump pump unit, including the main pump body, the tethered float switch, and the discharge outlet. The pump is black with the 'Everbilt' logo visible on its side.

Specifications

FeatureDetail
Model NumberSBA050BC
Horsepower (HP)0.5 HP
Voltage115 Volts (AC)
Amperage (Amps)6.5 Amps
Discharge Flow @ 0 ft.3800 gallons/hour
Discharge Flow @ 10 ft.3200 gallons/hour
Discharge Flow @ 15 ft.2500 gallons/hour
Minimum Working Temperature35°F (1.7°C)
Maximum Working Temperature77°F (25°C)
Cord Length10 ft.
Product Weight9.2 lb
Housing MaterialAluminum
Pump Switch TypeTethered Float
Sump Pump Outlet Diameter1-1/2 MPT x 1-1/4 FPT
Self-PrimingYes
SubmersibleYes

Setup and Installation

Pre-Installation Checklist:

Installation Steps:

  1. Position the Pump: Place the sump pump on a solid, level surface at the bottom of the sump basin. Ensure it is not resting directly on dirt or gravel.
  2. Connect Discharge Pipe: Attach a discharge pipe (minimum 1-1/4 inch diameter) to the pump's discharge outlet. It is recommended to use a check valve in the discharge line to prevent water from flowing back into the sump basin when the pump turns off.
  3. Adjust Float Switch: The tethered float switch must be positioned so it can move freely without obstruction. Ensure it can activate the pump at the desired water level and deactivate it before the pump runs dry. The tether length determines the operating range.
  4. Secure Wiring: Route the power cord away from any moving parts and ensure it is not pinched.
  5. Connect to Power: Once all connections are secure and the pump is properly positioned, plug the pump into a grounded 115V AC outlet.
  6. Test Operation: Fill the sump basin with water to verify the float switch activates the pump and water is discharged correctly. Ensure the pump shuts off when the water level drops.

Operation

The Everbilt 1/2 HP Submersible Sump Pump operates automatically via its tethered float switch. When the water level in the sump basin rises and lifts the float switch to its activation point, the pump will turn on and begin discharging water. Once the water level drops and the float switch returns to its lower position, the pump will turn off.

Maintenance

Regular maintenance ensures the longevity and reliable operation of your sump pump. Always disconnect power before performing any maintenance.

Troubleshooting

ProblemPossible CauseSolution
Pump does not turn on.No power; Float switch obstructed or defective; Motor overload.Check power supply and circuit breaker; Clear float switch path; Allow motor to cool and reset.
Pump runs but does not discharge water.Discharge pipe clogged; Impeller clogged; Check valve stuck closed; Air lock.Clear discharge pipe; Clean impeller; Inspect/replace check valve; Disconnect power, lift pump slightly, then reconnect to release air.
Pump runs continuously.Float switch stuck in "on" position; Check valve leaking; Pump undersized for inflow.Clear float switch path; Inspect/replace check valve; Consult a professional for pump sizing.
Pump cycles too frequently.Float switch set too low; Leaking check valve; Water back-flowing into sump.Adjust float switch for wider operating range; Inspect/replace check valve; Check for leaks in discharge system.

Warranty and Support

For warranty information or technical support, please refer to the documentation provided with your purchase or contact Everbilt customer service directly. Keep your purchase receipt as proof of purchase.

Related Documents - SBA050BC

Preview Everbilt Submersible Sump Pump Use and Care Guide | SBA025BC, SBA033BC, SBA033V1, SBA050BC
Comprehensive use and care guide for Everbilt submersible sump pumps, including installation, operation, safety information, maintenance, and troubleshooting for models SBA025BC, SBA033BC, SBA033V1, and SBA050BC. Find contact information and specifications.
Preview Everbilt Submersible Sump Pump Quick Reference Guide
This guide provides essential steps for installing and operating an Everbilt submersible sump pump. It covers preparing the sump basin, connecting the discharge pipe with a check valve and vent hole, plugging into a GFCI outlet, testing the pump's operation with its float switch, and installing an optional basin cover. Refer to the full instruction manual for comprehensive details.
Preview Everbilt Submersible Sump Pump Use and Care Guide (PSSP10001EP, PSSP07501VD)
This guide provides essential information for the safe and effective use, care, and maintenance of Everbilt submersible sump pumps, models PSSP10001EP and PSSP07501VD. It includes specifications, assembly instructions, operation details, and troubleshooting tips.
Preview Everbilt Submersible Sump Pump Use and Care Guide | SP03302EP, SP05002VD
This comprehensive guide provides essential information for the safe and effective use, care, and maintenance of Everbilt submersible sump pumps, models SP03302EP and SP05002VD. Learn about performance specifications, assembly, operation, troubleshooting, and warranty details.
Preview Everbilt Submersible Sump Pump Use and Care Guide
This guide provides essential information for the safe and effective use and care of Everbilt submersible sump pumps. It covers performance specifications, safety precautions, installation steps, operation, maintenance, and troubleshooting for models including SP03302VD, SP05002VD, PSSP07501VD, and PSSP10001VD.
Preview Everbilt Sump & Pedestal Pump Troubleshooting Guide
Comprehensive troubleshooting guide for Everbilt sump and pedestal pumps, covering common issues like pump not starting, low water delivery, frequent cycling, and loud operation. Includes safety instructions and contact information.