Antari FT-100

Antari FT-100 Fire Training Smoke Generator Instruction Manual

Model: FT-100 (51702602)

Brand: Antari

1. Introduction

The Antari FT-100 is a high-performance 1500 Watt smoke generator specifically designed for fire training applications. This robust unit produces dense, consistent smoke, enabling realistic simulation of fire conditions for various training exercises. This manual provides essential information for the safe and effective setup, operation, and maintenance of your FT-100 smoke generator.

Antari FT-100 Fire Training Smoke Generator, front-right view

Image 1.1: Front-right view of the Antari FT-100 Fire Training Smoke Generator. The device is red with black handles and a white fluid reservoir visible on top.

2. Safety Information

Read all safety instructions carefully before operating the Antari FT-100. Failure to follow these instructions may result in injury or damage to the unit.

Close-up of Antari FT-100 control panel with warning labels

Image 2.1: Close-up view of the Antari FT-100 control panel, showing the power switch, breaker, DMX ports, remote control port, and warning labels in multiple languages regarding fluid usage and safety.

3. Product Features

The Antari FT-100 is equipped with features designed for reliable and effective fire training simulations:

4. Setup

  1. Unpacking: Carefully remove the FT-100 from its packaging. Inspect the unit for any signs of damage during transit. Retain packaging for future storage or transport.
  2. Placement: Place the smoke generator on a stable, level surface in a well-ventilated area. Ensure the smoke output nozzle is unobstructed and directed appropriately for the training scenario. Maintain a safe distance from flammable materials and personnel.
  3. Fluid Filling:
    • Unscrew the cap of the fluid reservoir.
    • Carefully pour Antari fog liquid into the reservoir, ensuring not to overfill.
    • Securely replace the reservoir cap.
  4. Power Connection: Connect the power cable to the power inlet on the rear of the unit and then to a suitable grounded electrical outlet.
  5. Remote Control (Optional): If using a wired remote control, connect it to the "REMOTE CONTROL" port on the unit.
  6. DMX Connection (Optional): If integrating with a DMX system, connect your DMX controller to the DMX IN port. Use the DMX OUT port to daisy-chain to other DMX devices.
Rear view of Antari FT-100 showing power input, DMX ports, and remote control port

Image 4.1: Rear view of the Antari FT-100, highlighting the power input, DMX IN/OUT ports, and the remote control connection port.

5. Operating Instructions

  1. Power On: Flip the main power switch to the "ON" position. The unit will begin its warm-up cycle. The display will show "Antari FT-100" and then "Ready To Fog" once the operating temperature is reached. This typically takes several minutes.
  2. Smoke Output Control:
    • Manual Control: Press the "ON/OFF" button on the control panel or the remote control to manually activate smoke output. Release the button to stop.
    • Volume Adjustment: Use the "VOLUME" knob to adjust the intensity of the smoke output. Turn clockwise for more smoke, counter-clockwise for less.
    • Timer Function: Use the "TIMER" knob to set the duration and interval of automatic smoke bursts. Refer to the specific remote control manual for detailed timer programming.
  3. DMX Operation: If connected to a DMX controller, refer to the DMX channel assignment chart (usually found in a separate DMX supplement or on the manufacturer's website) to control smoke output, volume, and other functions via your DMX console.
  4. Power Off: After use, turn the main power switch to the "OFF" position. Allow the unit to cool down before moving or storing.
Antari FT-100 generating a long, continuous plume of smoke

Image 5.1: The Antari FT-100 in operation, emitting a long, steady plume of smoke, demonstrating its continuous output capability.

Antari FT-100 generating a dense, wide cloud of smoke

Image 5.2: The Antari FT-100 producing a dense, wide cloud of smoke, illustrating its capacity for high-volume output.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your FT-100 smoke generator.

7. Troubleshooting

If you encounter issues with your Antari FT-100, refer to the following common problems and solutions:

ProblemPossible CauseSolution
No smoke output
  • No power
  • No fog liquid
  • Unit not warmed up
  • Clogged nozzle/pump
  • Check power connection and circuit breaker.
  • Fill reservoir with Antari fog liquid.
  • Wait for "Ready To Fog" message on display.
  • Contact a qualified technician for service.
Weak or inconsistent smoke
  • Low fog liquid level
  • Incorrect fluid type
  • Partial clog
  • Refill reservoir.
  • Ensure only Antari fog liquid is used.
  • Contact a qualified technician for service.
Unit does not power on
  • Power cable disconnected
  • Circuit breaker tripped
  • Internal fault
  • Check power cable connection.
  • Reset the breaker on the unit and/or the wall outlet.
  • Contact Antari support or a qualified technician.

If the problem persists after attempting these solutions, contact Antari customer support or a qualified service technician.

8. Specifications

ModelFT-100 (51702602)
Power1500 Watts
Dimensions (L x W x H)26.18 x 14.37 x 13.39 inches
Weight35.1 pounds
MaterialAluminum
ColorRed

9. Warranty and Support

Antari products are manufactured to high standards and are backed by a limited warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Antari website.

For technical support, service inquiries, or to purchase genuine Antari fog liquid and accessories, please contact your authorized Antari dealer or visit the Antari official website for contact information.

Website: www.antari.com

Related Documents - FT-100

Preview Antari FT-100 Fire Training Fog Machine User Manual
Comprehensive user manual for the Antari FT-100 Fire Training Fog Machine, detailing setup, operation, safety precautions, maintenance, and technical specifications. Essential for fire training simulations.
Preview Antari FT-20X Fire Training Fog Machine User Manual
User manual for the Antari FT-20X Fire Training Fog Machine, providing detailed instructions on safety, setup, operation, DMX control, remote operation, maintenance, and technical specifications.
Preview Antari FT-55 Smoke Generator User Manual - Operation, Safety, and Specifications
Comprehensive user manual for the Antari FT-55 Pumpless Off-Mains Capable Smoke Generator. Covers safety, operation, maintenance, technical specifications, and spare parts.
Preview Antari FT-200 Fire Training Fog Machine User Manual
Comprehensive user manual for the Antari FT-200 Fire Training Fog Machine. This guide covers essential safety information, unpacking and inspection, product overview, setup instructions, detailed operation modes (timer, volume, DMX, wireless), control panel functions, menu settings, fluid recommendations, maintenance procedures, breaker reset, and technical specifications.
Preview Antari FT-70 Fire Training Fog Machine User Manual
Comprehensive user manual for the Antari FT-70 Fire Training Fog Machine, covering safety, operation, maintenance, specifications, and troubleshooting. Includes details on wireless remote control and grounding instructions.
Preview Antari N-100 Fog Machine User Manual
Comprehensive user manual for the Antari N-100 Fog Machine, detailing installation, operation, safety precautions, technical specifications, maintenance, and warranty information.