1. Introduction
The Antari FT-100 is a high-performance 1500 Watt smoke generator specifically designed for fire training applications. This robust unit produces dense, consistent smoke, enabling realistic simulation of fire conditions for various training exercises. This manual provides essential information for the safe and effective setup, operation, and maintenance of your FT-100 smoke generator.

Image 1.1: Front-right view of the Antari FT-100 Fire Training Smoke Generator. The device is red with black handles and a white fluid reservoir visible on top.
2. Safety Information
Read all safety instructions carefully before operating the Antari FT-100. Failure to follow these instructions may result in injury or damage to the unit.
- Use Only Antari Fog Liquid: This device is designed to operate exclusively with Antari brand fog liquid. Using other liquids may cause damage to the unit and void the warranty.
- Do Not Operate Without Liquid: Ensure the fluid reservoir contains an adequate amount of Antari fog liquid before powering on the unit. Operating the machine dry can cause severe damage to the heating element and pump.
- Indoor Use Only: This smoke generator is intended for indoor use in controlled environments. Do not expose it to rain, moisture, or extreme temperatures.
- Keep Out of Reach of Children: The device contains electrical components and hot surfaces. Store and operate it in a location inaccessible to children.
- Ventilation: Ensure adequate ventilation in the operating area. While the smoke is non-toxic, prolonged exposure in poorly ventilated spaces can cause discomfort.
- Electrical Safety: Connect the unit to a grounded power outlet with the correct voltage. Do not overload electrical circuits. Disconnect power before performing any maintenance or refilling the fluid.
- Hot Surfaces: The nozzle and surrounding areas become hot during operation. Avoid direct contact to prevent burns.
- Fluid Handling: Avoid skin and eye contact with fog liquid. In case of contact, rinse thoroughly with water. Do not ingest fog liquid.

Image 2.1: Close-up view of the Antari FT-100 control panel, showing the power switch, breaker, DMX ports, remote control port, and warning labels in multiple languages regarding fluid usage and safety.
3. Product Features
The Antari FT-100 is equipped with features designed for reliable and effective fire training simulations:
- High Output: A 1500 Watt heating element ensures rapid warm-up and continuous, high-volume smoke production.
- Durable Construction: Housed in a robust aluminum casing, providing durability for demanding training environments.
- Integrated Fluid Reservoir: Features a large, easily accessible reservoir for Antari fog liquid.
- User-Friendly Controls: Intuitive control panel with a digital display, volume knob, and timer function for precise smoke output management.
- Remote Control Capability: Includes a dedicated port for connecting a wired remote control (remote sold separately or included depending on package).
- DMX Connectivity: Equipped with DMX IN and OUT ports for integration into professional control systems.
4. Setup
- Unpacking: Carefully remove the FT-100 from its packaging. Inspect the unit for any signs of damage during transit. Retain packaging for future storage or transport.
- Placement: Place the smoke generator on a stable, level surface in a well-ventilated area. Ensure the smoke output nozzle is unobstructed and directed appropriately for the training scenario. Maintain a safe distance from flammable materials and personnel.
- Fluid Filling:
- Unscrew the cap of the fluid reservoir.
- Carefully pour Antari fog liquid into the reservoir, ensuring not to overfill.
- Securely replace the reservoir cap.
- Power Connection: Connect the power cable to the power inlet on the rear of the unit and then to a suitable grounded electrical outlet.
- Remote Control (Optional): If using a wired remote control, connect it to the "REMOTE CONTROL" port on the unit.
- DMX Connection (Optional): If integrating with a DMX system, connect your DMX controller to the DMX IN port. Use the DMX OUT port to daisy-chain to other DMX devices.

Image 4.1: Rear view of the Antari FT-100, highlighting the power input, DMX IN/OUT ports, and the remote control connection port.
5. Operating Instructions
- Power On: Flip the main power switch to the "ON" position. The unit will begin its warm-up cycle. The display will show "Antari FT-100" and then "Ready To Fog" once the operating temperature is reached. This typically takes several minutes.
- Smoke Output Control:
- Manual Control: Press the "ON/OFF" button on the control panel or the remote control to manually activate smoke output. Release the button to stop.
- Volume Adjustment: Use the "VOLUME" knob to adjust the intensity of the smoke output. Turn clockwise for more smoke, counter-clockwise for less.
- Timer Function: Use the "TIMER" knob to set the duration and interval of automatic smoke bursts. Refer to the specific remote control manual for detailed timer programming.
- DMX Operation: If connected to a DMX controller, refer to the DMX channel assignment chart (usually found in a separate DMX supplement or on the manufacturer's website) to control smoke output, volume, and other functions via your DMX console.
- Power Off: After use, turn the main power switch to the "OFF" position. Allow the unit to cool down before moving or storing.

Image 5.1: The Antari FT-100 in operation, emitting a long, steady plume of smoke, demonstrating its continuous output capability.

Image 5.2: The Antari FT-100 producing a dense, wide cloud of smoke, illustrating its capacity for high-volume output.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your FT-100 smoke generator.
- Exterior Cleaning: Wipe the exterior of the unit with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the unit is unplugged before cleaning.
- Fluid Reservoir: Periodically check the fluid reservoir for any debris. If storing the unit for an extended period, it is recommended to empty the reservoir and run a small amount of distilled water through the system to prevent clogs.
- Nozzle Cleaning: If smoke output becomes weak or inconsistent, the nozzle may be partially clogged. Consult a qualified technician for cleaning or replacement of internal components. Do not attempt to disassemble the unit yourself.
- Storage: Store the unit in a cool, dry place, away from direct sunlight and extreme temperatures.
7. Troubleshooting
If you encounter issues with your Antari FT-100, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No smoke output |
|
|
| Weak or inconsistent smoke |
|
|
| Unit does not power on |
|
|
If the problem persists after attempting these solutions, contact Antari customer support or a qualified service technician.
8. Specifications
| Model | FT-100 (51702602) |
| Power | 1500 Watts |
| Dimensions (L x W x H) | 26.18 x 14.37 x 13.39 inches |
| Weight | 35.1 pounds |
| Material | Aluminum |
| Color | Red |
9. Warranty and Support
Antari products are manufactured to high standards and are backed by a limited warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Antari website.
For technical support, service inquiries, or to purchase genuine Antari fog liquid and accessories, please contact your authorized Antari dealer or visit the Antari official website for contact information.
Website: www.antari.com