1. Introduction
This manual provides essential information for the proper installation, operation, and maintenance of your Goodman 5 TON 15.2 SEER2 R-32 AC Condenser, model GLXS5BA6010. Please read this manual thoroughly before attempting to install or operate the unit. Retain this manual for future reference.
2. Safety Information
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Installation and service must be performed by a qualified installer or service agency.
- Always disconnect power to the unit before performing any service or maintenance.
- Wear appropriate personal protective equipment (PPE) such as gloves and safety glasses.
- Ensure proper grounding of the unit to prevent electrical shock.
- The refrigerant R-32 is mildly flammable. Handle with care and ensure adequate ventilation during service. Refer to local codes and regulations for R-32 handling.
- Keep children and pets away from the unit during operation and maintenance.
3. Setup and Installation
The Goodman 5 TON 15.2 SEER2 R-32 AC Condenser is designed for split system residential air conditioning applications. Due to the complexity of HVAC systems and the specific requirements for handling R-32 refrigerant, installation must be performed by a certified HVAC professional.
Key installation considerations include:
- Proper sizing of the unit for the conditioned space.
- Secure and level mounting of the outdoor condenser unit.
- Correct refrigerant line sizing and connection.
- Accurate electrical wiring and circuit protection.
- Evacuation of the refrigerant lines to remove moisture and non-condensables.
- Charging the system with the correct amount of R-32 refrigerant.

4. Operating Instructions
Once installed by a qualified technician, your Goodman AC Condenser will work in conjunction with an indoor coil and thermostat to provide cooling. Operation is typically controlled via a compatible thermostat.
General operating steps:
- Ensure the thermostat is set to 'Cool' mode.
- Set the desired temperature. The unit will cycle on and off to maintain this temperature.
- Keep all vents and registers clear of obstructions for optimal airflow.
- Avoid frequently changing thermostat settings, as this can reduce efficiency.
This unit utilizes R-32 refrigerant, which offers improved environmental performance compared to older refrigerants. For more information on R-32, please watch the following informational video:
5. Maintenance
Regular maintenance is crucial for the efficiency and longevity of your AC condenser. While some tasks can be performed by the homeowner, annual professional maintenance is highly recommended.
Homeowner maintenance tasks:
- Clean the outdoor unit: Periodically remove leaves, grass clippings, and other debris from around the condenser unit. Ensure the coils are free of obstructions.
- Check the air filter: Inspect and replace or clean the indoor unit's air filter monthly, or as recommended by the filter manufacturer. A dirty filter restricts airflow and reduces efficiency.
- Keep the area clear: Maintain at least 2 feet of clearance around the outdoor unit for proper airflow.
Professional maintenance typically includes:
- Checking refrigerant levels and pressure.
- Cleaning condenser and evaporator coils.
- Inspecting electrical connections and components.
- Lubricating moving parts (if applicable).
- Checking thermostat calibration.
- Inspecting the condensate drain for blockages.
6. Troubleshooting
Before calling for service, review these common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit not turning on | No power, thermostat issue, tripped breaker | Check circuit breaker, ensure thermostat is set correctly, contact technician if issue persists. |
| Insufficient cooling | Dirty air filter, blocked outdoor unit, low refrigerant, undersized unit | Clean/replace air filter, clear debris from outdoor unit, contact technician for refrigerant check. |
| Unit runs constantly | Thermostat setting too low, dirty coils, low refrigerant | Adjust thermostat, clean outdoor unit, contact technician for inspection. |
| Unusual noises | Loose parts, fan motor issue, compressor problem | Turn off unit immediately and contact a qualified technician. |
For any issues not resolved by these steps, or for complex problems, contact a qualified HVAC service technician.
7. Specifications
| Feature | Detail |
|---|---|
| Brand | Goodman |
| Model | GLXS5BA6010 |
| Capacity | 5 Tons |
| SEER2 Rating | 15.2 |
| Refrigerant Type | R-32 |
| Installation Type | Split System |
| Compressor Type | Rotary Scroll |
| Power Source | Air Powered |
| Application | Residential |
| Color | Black |
| Additional Features | Energy-Efficient Mode |
| Unit Count | 1.0 Count |
| ASIN | B013GLXRR2 |
8. Warranty Information
This Goodman AC Condenser comes with a Limited Warranty. Specific terms and conditions of the warranty, including coverage duration and exclusions, are provided with the product documentation at the time of purchase. Please refer to your warranty certificate for complete details.
To ensure warranty validity, all installation and service must be performed by a licensed HVAC professional.
9. Support
For technical assistance, service inquiries, or to locate a qualified Goodman HVAC professional, please visit the official Goodman website or contact their customer support directly. When contacting support, please have your model number (GLXS5BA6010) and serial number ready.
Goodman Official Website: www.goodmanmfg.com