Goodman GLXS5BA6010

Goodman 5 TON 15.2 SEER2 R-32 AC Condenser

Model: GLXS5BA6010

1. Introduction

This manual provides essential information for the proper installation, operation, and maintenance of your Goodman 5 TON 15.2 SEER2 R-32 AC Condenser, model GLXS5BA6010. Please read this manual thoroughly before attempting to install or operate the unit. Retain this manual for future reference.

2. Safety Information

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Installation and service must be performed by a qualified installer or service agency.

  • Always disconnect power to the unit before performing any service or maintenance.
  • Wear appropriate personal protective equipment (PPE) such as gloves and safety glasses.
  • Ensure proper grounding of the unit to prevent electrical shock.
  • The refrigerant R-32 is mildly flammable. Handle with care and ensure adequate ventilation during service. Refer to local codes and regulations for R-32 handling.
  • Keep children and pets away from the unit during operation and maintenance.

3. Setup and Installation

The Goodman 5 TON 15.2 SEER2 R-32 AC Condenser is designed for split system residential air conditioning applications. Due to the complexity of HVAC systems and the specific requirements for handling R-32 refrigerant, installation must be performed by a certified HVAC professional.

Key installation considerations include:

  • Proper sizing of the unit for the conditioned space.
  • Secure and level mounting of the outdoor condenser unit.
  • Correct refrigerant line sizing and connection.
  • Accurate electrical wiring and circuit protection.
  • Evacuation of the refrigerant lines to remove moisture and non-condensables.
  • Charging the system with the correct amount of R-32 refrigerant.
Goodman 5 TON 15.2 SEER2 R-32 AC Condenser outdoor unit
Image: Goodman 5 TON 15.2 SEER2 R-32 AC Condenser outdoor unit. This image shows the exterior of the condenser unit, typically installed outside a residence.

4. Operating Instructions

Once installed by a qualified technician, your Goodman AC Condenser will work in conjunction with an indoor coil and thermostat to provide cooling. Operation is typically controlled via a compatible thermostat.

General operating steps:

  1. Ensure the thermostat is set to 'Cool' mode.
  2. Set the desired temperature. The unit will cycle on and off to maintain this temperature.
  3. Keep all vents and registers clear of obstructions for optimal airflow.
  4. Avoid frequently changing thermostat settings, as this can reduce efficiency.

This unit utilizes R-32 refrigerant, which offers improved environmental performance compared to older refrigerants. For more information on R-32, please watch the following informational video:

Video: R-32 Fact vs Fiction. This video provides factual information regarding R-32 refrigerant, addressing common misconceptions and highlighting its benefits.

5. Maintenance

Regular maintenance is crucial for the efficiency and longevity of your AC condenser. While some tasks can be performed by the homeowner, annual professional maintenance is highly recommended.

Homeowner maintenance tasks:

  • Clean the outdoor unit: Periodically remove leaves, grass clippings, and other debris from around the condenser unit. Ensure the coils are free of obstructions.
  • Check the air filter: Inspect and replace or clean the indoor unit's air filter monthly, or as recommended by the filter manufacturer. A dirty filter restricts airflow and reduces efficiency.
  • Keep the area clear: Maintain at least 2 feet of clearance around the outdoor unit for proper airflow.

Professional maintenance typically includes:

  • Checking refrigerant levels and pressure.
  • Cleaning condenser and evaporator coils.
  • Inspecting electrical connections and components.
  • Lubricating moving parts (if applicable).
  • Checking thermostat calibration.
  • Inspecting the condensate drain for blockages.

6. Troubleshooting

Before calling for service, review these common issues and solutions:

ProblemPossible CauseSolution
Unit not turning onNo power, thermostat issue, tripped breakerCheck circuit breaker, ensure thermostat is set correctly, contact technician if issue persists.
Insufficient coolingDirty air filter, blocked outdoor unit, low refrigerant, undersized unitClean/replace air filter, clear debris from outdoor unit, contact technician for refrigerant check.
Unit runs constantlyThermostat setting too low, dirty coils, low refrigerantAdjust thermostat, clean outdoor unit, contact technician for inspection.
Unusual noisesLoose parts, fan motor issue, compressor problemTurn off unit immediately and contact a qualified technician.

For any issues not resolved by these steps, or for complex problems, contact a qualified HVAC service technician.

7. Specifications

FeatureDetail
BrandGoodman
ModelGLXS5BA6010
Capacity5 Tons
SEER2 Rating15.2
Refrigerant TypeR-32
Installation TypeSplit System
Compressor TypeRotary Scroll
Power SourceAir Powered
ApplicationResidential
ColorBlack
Additional FeaturesEnergy-Efficient Mode
Unit Count1.0 Count
ASINB013GLXRR2

8. Warranty Information

This Goodman AC Condenser comes with a Limited Warranty. Specific terms and conditions of the warranty, including coverage duration and exclusions, are provided with the product documentation at the time of purchase. Please refer to your warranty certificate for complete details.

To ensure warranty validity, all installation and service must be performed by a licensed HVAC professional.

9. Support

For technical assistance, service inquiries, or to locate a qualified Goodman HVAC professional, please visit the official Goodman website or contact their customer support directly. When contacting support, please have your model number (GLXS5BA6010) and serial number ready.

Goodman Official Website: www.goodmanmfg.com

© 2023 Goodman Manufacturing Company, L.P. All rights reserved.

Related Documents - GLXS5BA6010

Preview Goodman GPHH5 Packaged Heat Pumps: Specifications and Features
Comprehensive overview of the Goodman GPHH5 Series Packaged Heat Pumps, detailing standard and cabinet features, model nomenclature, key specifications including SEER2 ratings, cooling/heating capacities, airflow data, electrical requirements, dimensions, available accessories, and warranty information.
Preview Goodman GPCH3 Packaged Air Conditioner Specifications and Features
Comprehensive guide to the Goodman GPCH3 series packaged air conditioners, covering standard and cabinet features, nomenclature, detailed product specifications, expanded cooling and airflow data, electrical information for heat kits, dimensions, wiring diagrams, and available accessories. Designed for efficiency and durability, these units are available in 2 to 5 tons with 13.4 SEER2 ratings.
Preview Goodman GPG13 Packaged Gas/Electric Unit Product Specifications
Detailed product specifications for the Goodman GPG13 series of single-phase, self-contained packaged gas/electric units, covering features, cabinet details, nomenclature, specifications, dimensions, wiring diagrams, and accessories.
Preview Goodman GPCH3 Series Packaged Air Conditioner - Specifications and Data
Comprehensive guide to the Goodman GPCH3 series packaged air conditioners, detailing specifications, nomenclature, airflow, electrical data, dimensions, and accessories for units ranging from 2 to 5 tons with 13.4 SEER2 efficiency.
Preview Goodman GSX16 Energy-Efficient Split System Air Conditioner Specifications
Detailed specifications, features, and performance data for the Goodman GSX16 series energy-efficient split system air conditioner, offering up to 16 SEER cooling capacity from 1 to 5 tons. Includes model nomenclature, electrical data, dimensions, and accessory information.
Preview Goodman & Amana Split System HVAC Service Instructions for R-22 Units
Comprehensive service instructions manual for Goodman and Amana split system air conditioners and heat pumps utilizing R-22 refrigerant. Covers product identification, design, system operation, troubleshooting, and detailed servicing procedures for qualified HVAC technicians.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.