1. Product Overview

The First Alert CO710 Carbon Monoxide Alarm provides continuous monitoring for dangerous carbon monoxide (CO) levels for up to 10 years. This device utilizes an advanced electrochemical CO sensor, recognized as the most accurate detection technology available. Designed for convenience and safety, it features a built-in 10-year lithium battery, eliminating the need for battery replacements throughout the alarm's lifespan. Its sleek design allows for versatile placement on a dresser or tabletop, and a backlit digital display provides clear readings of ambient temperature, as well as current and peak CO concentrations.

An 85-decibel horn alerts you to high carbon monoxide levels, ensuring timely warning. A test/silence button is integrated for easy functionality testing and alarm silencing.

First Alert CO710 Carbon Monoxide Detector protecting a family

Image: The First Alert CO710 Carbon Monoxide Detector provides peace of mind for families.

2. Setup and Placement

2.1 Activation

To activate the alarm, locate the switch on the back of the unit and move it to the 'ON' position. After activation, press and hold the 'TEST/SILENCE' button to ensure the alarm is functioning correctly.

2.2 Placement Guidelines

The CO710 is designed for flexible placement. It can be conveniently placed on a dresser, nightstand, or tabletop. For optimal safety, install carbon monoxide alarms on every level of your home and in every bedroom. Avoid placing the detector in areas with high humidity, extreme temperatures, or where it might be obstructed.

First Alert CO710 Carbon Monoxide Detector on a wooden surface, indicating no installation needed

Image: The First Alert CO710 is designed for easy tabletop placement, requiring no complex installation.

Diagram showing recommended placement of CO alarms in a house, including bedrooms, hallway, living room, kitchen, and basement

Image: Recommended placement for carbon monoxide alarms includes one on every level and in every bedroom.

3. Operating Instructions

3.1 Digital Display

The backlit digital display provides real-time information:

  • Ambient Temperature: Shows the current room temperature.
  • CO Concentration: Displays current carbon monoxide levels in parts per million (PPM).
  • Peak CO Levels: Indicates the highest CO concentration detected since the last reset.
Close-up of First Alert CO710 digital display showing temperature and CO levels

Image: The digital display clearly shows temperature and carbon monoxide concentration.

3.2 Alarm Signals

The CO710 uses distinct chirps and beeps to indicate different statuses:

  • 5 Chirps: End of Life Signal - Indicates the unit needs to be replaced.
  • 3 Chirps: Malfunction - Indicates a fault with the unit.
  • 4 Beeps: CO Alarm - Indicates dangerous levels of carbon monoxide detected.

3.3 Test/Silence Button

Press the 'TEST/SILENCE' button to:

  • Test Functionality: Verify the alarm's sensor and circuitry are working.
  • Silence Alarm: Temporarily silence the alarm during a non-emergency event (e.g., cooking fumes).

Video: Official First Alert video demonstrating the features and operation of Carbon Monoxide Alarms.

4. Maintenance

4.1 Battery Life

The CO710 features a sealed, built-in 10-year lithium battery. This battery is not replaceable and is designed to power the unit for its entire 10-year lifespan, providing continuous protection without the need for battery changes.

First Alert CO710 Carbon Monoxide Detector with dimensions and 'Battery Operated' icon

Image: The CO710 is battery operated with a 10-year sealed battery.

4.2 End-of-Life Signal

When the alarm reaches the end of its 10-year operational life, it will emit 5 chirps to signal that it's time for replacement. This ensures you are always protected by a fully functional device.

4.3 Regular Testing

It is crucial to test your carbon monoxide alarm weekly to ensure it is operating correctly. Press and hold the 'TEST/SILENCE' button until the alarm sounds. If it does not sound, refer to the troubleshooting section.

A hand pressing the test button on a First Alert CO detector with a 'Test alarms regularly' icon

Image: Regularly test your CO alarm to ensure proper function.

4.4 Cleaning

Gently vacuum the alarm monthly to prevent dust and debris from interfering with its sensor.

4.5 Replacement

Replace the alarm at least every 10 years, or immediately if the end-of-life signal sounds. The alarm cannot be reactivated once deactivated.

A person replacing a wall-mounted CO alarm with a 'Replace alarms at least every 10 years' icon

Image: Replace your CO alarm every 10 years for continued safety.

5. Troubleshooting

5.1 CO Alarm (4 Beeps)

If the alarm sounds with 4 beeps, it indicates the presence of carbon monoxide. Immediately move to fresh air, either outdoors or by opening a door/window. Call your emergency services (Fire Department or 911) from a safe location.

5.2 Malfunction (3 Chirps)

If the alarm emits 3 chirps, it indicates a malfunction. The unit may not be able to detect CO effectively. Contact customer service for assistance.

5.3 End of Life Signal (5 Chirps)

If the alarm emits 5 chirps, it has reached the end of its operational life. The unit must be replaced immediately to ensure continued protection.

6. Specifications

FeatureSpecification
Model NumberCO710
BrandFirst Alert
Power SourceBattery Powered (10-Year Sealed Lithium Metal Battery Included)
Sensor TypeElectrochemical
Alarm Sound Level85 Decibels
DisplayDigital with Backlight (shows temperature, current CO, peak CO)
Product Dimensions0.9"D x 4.8"W x 2.6"H
Item Weight6.4 ounces
Operating Humidity10-95% RH
CertificationsUL Standards

7. Warranty and Support

7.1 Limited Warranty

The First Alert CO710 Carbon Monoxide Detector comes with a 10-year limited warranty. This warranty covers defects in material and workmanship from the date of purchase. Please retain your original sales receipt as proof of purchase.

7.2 Customer Support

For replacement user manuals, warranty claims, or any product-related inquiries, please contact the First Alert customer service team:

Related Documents - CO710

Preview First Alert Smoke and Carbon Monoxide Alarms User Manuals
Comprehensive user manuals for First Alert 9120LBLA Hardwire Smoke Alarm and First Alert CO615A Carbon Monoxide Plug-In Alarm, covering installation, operation, maintenance, safety, and troubleshooting.
Preview First Alert SMCO410 Smoke and Carbon Monoxide Alarm User Manual
Comprehensive user manual for the First Alert SMCO410 Smoke and Carbon Monoxide Alarm, detailing installation, operation, maintenance, troubleshooting, and warranty information.
Preview First Alert SC5 Wireless Smart Smoke & Carbon Monoxide Alarm Installation Guide
Installation guide for the First Alert SC5 Wireless Smart Smoke & Carbon Monoxide Alarm (SMC0600NV), covering setup, placement, maintenance, and regulatory information.
Preview First Alert SC5 Wireless Smart Smoke & Carbon Monoxide Alarm Quick Start Guide
Quick start guide for the First Alert SC5 Wireless Smart Smoke & Carbon Monoxide Alarm (Model SMC0600NV). Includes setup, placement, functions, maintenance, troubleshooting, and regulatory information.
Preview First Alert CO615 Plug-In Carbon Monoxide Alarm User Manual
Comprehensive user manual for the First Alert CO615 Plug-In Carbon Monoxide Alarm, covering safety information, installation, operation, maintenance, troubleshooting, and warranty details.
Preview First Alert SC5 Wireless Smart Smoke & Carbon Monoxide Alarm Quick Start Guide
Quick start guide for the First Alert SC5 Wireless Smart Smoke & Carbon Monoxide Alarm (SMC0600NV), covering setup, installation, placement, maintenance, and troubleshooting.