Introduction
This manual provides detailed instructions for the safe installation, operation, and maintenance of your Tecnolite FTL-3200/BA Wall Lantern. Please read this manual thoroughly before installation and retain it for future reference. The FTL-3200/BA is an outdoor wall-mounted luminaire designed to provide illumination with an E27 base, suitable for 100-240V~ power supply and rated at 26W. It features an Antique Bronze finish and is constructed from aluminum, with an IP44 rating for outdoor use, specifically in locations under a ceiling.
Safety Information
- Electrical Safety: Always disconnect power at the circuit breaker or fuse box before installing, servicing, or cleaning this fixture. Failure to do so may result in electric shock or death.
- Qualified Electrician: Installation should be performed by a qualified electrician or a person familiar with the construction and operation of the product and the hazards involved.
- Grounding: Ensure the fixture is properly grounded to avoid potential electrical hazards.
- Outdoor Use: This luminaire is rated IP44 for outdoor use. It must always be installed in a location under a ceiling to protect it from direct exposure to heavy rain or harsh weather conditions.
- Bulb Type: Use only E27 base fluorescent lamps up to 26W. Do not exceed the maximum wattage specified.
- Handling: Handle the fixture with care. Avoid dropping or subjecting it to strong impacts.
Package Contents
Verify that all components are present and undamaged before beginning installation.
- Tecnolite FTL-3200/BA Wall Lantern (1 unit)
- Mounting Hardware (screws, wall anchors, wire connectors)
- Instruction Manual (this document)
Note: An E27 fluorescent lamp (up to 26W) is not included and must be purchased separately.
Setup and Installation
Follow these steps carefully to install your wall lantern.
- Prepare for Installation:
- Turn off the electrical power at the main fuse or circuit breaker box.
- Ensure the mounting surface is clean, dry, and structurally sound.
- Unpack the fixture and its components.
- Mounting the Fixture:
- Attach the mounting bracket (if separate) to the junction box using the provided screws.
- Connect the electrical wires:
- Connect the green or bare copper ground wire from the fixture to the ground wire from the junction box.
- Connect the white wire from the fixture to the white (neutral) wire from the junction box.
- Connect the black wire from the fixture to the black (hot) wire from the junction box.
- Secure all connections with wire connectors and wrap with electrical tape.
- Carefully tuck all wires into the junction box.
- Align the fixture with the mounting bracket and secure it with the provided screws or nuts.
- Install the Bulb:
- Unscrew the glass shade or access panel to expose the E27 lamp holder.
- Carefully screw an E27 base fluorescent lamp (max 26W) into the socket until snug. Do not overtighten.
- Reattach the glass shade or access panel securely.
- Restore Power: Turn the electrical power back on at the main fuse or circuit breaker box.

Image: The Tecnolite FTL-3200/BA Wall Lantern installed on an exterior brick wall, demonstrating its appearance when illuminated.

Image: A detailed front view of the Tecnolite FTL-3200/BA Wall Lantern, showcasing its antique bronze finish and the textured clear seeded glass panels.

Image: A technical drawing illustrating the dimensions of the Tecnolite FTL-3200/BA Wall Lantern, with a height of 340mm and a width of 180mm.
Operating Instructions
Once installed and powered, the Tecnolite FTL-3200/BA Wall Lantern operates via your standard wall switch connected to the circuit. Simply toggle the wall switch to turn the light fixture on or off.
- Turning On: Flip the connected wall switch to the "ON" position.
- Turning Off: Flip the connected wall switch to the "OFF" position.
Maintenance
Regular maintenance ensures the longevity and optimal performance of your wall lantern.
- Cleaning:
- Ensure power is disconnected before cleaning.
- Wipe the fixture with a soft, damp cloth. Do not use abrasive cleaners or solvents, as they may damage the finish or glass.
- Clean the glass panels periodically to maintain light output.
- Bulb Replacement:
- Always disconnect power before replacing the bulb.
- Allow the old bulb to cool completely before touching it.
- Unscrew the glass shade or access panel.
- Carefully unscrew the old E27 bulb and replace it with a new E27 fluorescent lamp (max 26W).
- Securely reattach the glass shade or access panel.
- Inspection: Periodically inspect the fixture for any signs of wear, damage, or loose connections. Address any issues promptly.
Troubleshooting
If your wall lantern is not functioning correctly, refer to the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on. |
|
|
| Light flickers. |
|
|
If troubleshooting steps do not resolve the issue, contact customer support or a qualified electrician.
Specifications
| Brand | Tecnolite |
| Model Name | PETRA |
| Part Number | FTL-3200/BA |
| Color | Antique Bronze |
| Material | Aluminum |
| Style | Antique |
| Product Dimensions (L x W x H) | 7.09" x 5.98" x 13.39" (180mm x 152mm x 340mm) |
| Power Source | Corded Electric |
| Voltage | 100 - 240 V ~ |
| Wattage | 26 W (Max) |
| Bulb Base | E27 |
| Light Source Type | Fluorescent (Bulb not included) |
| IP Rating | IP44 (Suitable for outdoor use under a ceiling) |
| Item Weight | 3.7 pounds (1.68 Kilograms) |
| Assembly Required | No (Mounting hardware included) |
Warranty and Support
Tecnolite products are manufactured to high-quality standards. For information regarding warranty coverage, please refer to the warranty card included with your purchase or visit the official Tecnolite website. For technical support, replacement parts, or any questions not covered in this manual, please contact Tecnolite customer service through their official channels.