Introduction
This manual provides essential information for the installation, operation, and maintenance of the FAAC 455D (115V) Control Panel. The Model 455D control panel is designed to operate various FAAC gate operators, including Model 415 (115V version), Model 400, Model 402, Model 422, Model 750, Model 760, and Model 615. It is crucial to read and understand all instructions before proceeding with installation or operation.
Components Included
The FAAC 455D (115V) Control Panel kit typically includes the following components:
- FAAC 455D (115V version) Control Panel with Circuit Board
- Two Remote Controls
- Receiver

Image: The FAAC 455D Control Panel kit, showing the metal enclosure with internal wiring and diagrams, the separate circuit board, and the product packaging box.
Setup and Installation
Installation of the FAAC 455D Control Panel should be performed by qualified personnel only, adhering to all local electrical codes and safety regulations. Incorrect installation can lead to serious injury or damage to equipment.
Pre-Installation Checks:
- Ensure the power supply matches the panel's requirements (115V).
- Verify that the FAAC operator you intend to connect is compatible with the 455D panel.
- Inspect all components for any signs of damage before installation.
Mounting the Control Panel:
Mount the control panel enclosure in a secure, dry location, protected from direct weather exposure and excessive vibrations. Ensure adequate ventilation around the unit.
Wiring Connections:
Refer to the detailed wiring diagrams provided inside the control panel enclosure and in the complete product manual for specific connection points. Proper wiring is critical for safe and correct operation. Connections typically include:
- Main power input (115V AC)
- Motor connections for the gate operator
- Safety device connections (e.g., photocells, safety edges)
- Accessory connections (e.g., keypads, intercoms)
- Receiver connection for remote controls
After all connections are made, secure all wiring and close the enclosure. Do not apply power until all connections are verified.
Operating Instructions
Once the FAAC 455D Control Panel is correctly installed and powered, it controls the connected FAAC gate operator. Operation is typically initiated via remote control or other access devices.
Remote Control Pairing:
To use the included remote controls, they must be paired with the receiver connected to the 455D control panel. The specific pairing procedure can vary slightly; consult the detailed instructions provided with the remote controls or the full FAAC 455D manual for precise steps. Generally, this involves pressing a programming button on the receiver or control board and then activating the remote control button.
Basic Operation:
- Opening/Closing: Pressing the programmed button on the remote control will initiate the gate's movement (open or close, depending on its current state).
- Stop Function: A second press of the remote control button during gate movement will typically stop the gate.
- Safety Features: The control panel integrates with safety devices like photocells. If an obstruction is detected during closing, the gate will reverse or stop to prevent impact.
For advanced settings, such as automatic closing times, force adjustments, or pedestrian modes, refer to the comprehensive FAAC 455D programming manual.
Maintenance
Regular maintenance ensures the longevity and reliable operation of your FAAC 455D Control Panel and the connected gate system. Always disconnect power to the control panel before performing any maintenance.
Routine Checks:
- Visual Inspection: Periodically inspect the control panel enclosure for any signs of damage, corrosion, or water ingress. Ensure the lid is securely closed.
- Wiring: Check all wiring connections for tightness and ensure there are no frayed or exposed wires.
- Cleanliness: Keep the interior of the control panel clean and free of dust, insects, or debris. Use a soft, dry brush or compressed air for cleaning.
- Safety Devices: Regularly test all connected safety devices (e.g., photocells) to ensure they are functioning correctly.
Do not attempt to repair the circuit board or internal components yourself. Contact a qualified technician for any repairs beyond basic cleaning and inspection.
Troubleshooting
Before contacting technical support, review the following common issues and their potential solutions. Always ensure power is disconnected before inspecting internal components.
| Problem | Possible Cause | Solution |
|---|---|---|
| Gate does not respond to remote control. |
|
|
| Gate stops or reverses unexpectedly. |
|
|
| Control panel lights are off. |
|
|
If the problem persists after attempting these solutions, it is recommended to contact a qualified technician or the manufacturer's support.
Specifications
Key specifications for the FAAC 455D (115V) Control Panel:
- Model: 455D (115V)
- Manufacturer: FAAC
- Compatibility: Designed for FAAC operators including Model 415 (115V version), Model 400, Model 402, Model 422, Model 750, Model 760, Model 615.
- Power Input: 115V AC (as indicated by model name)
- Date First Available: May 12, 2015
- ASIN: B00XK4TTBY
Warranty Information
Specific warranty terms for the FAAC 455D (115V) Control Panel are typically provided by the manufacturer, FAAC, or the authorized seller at the time of purchase. It is recommended to retain your proof of purchase and consult the documentation included with your product for detailed warranty coverage, duration, and conditions. Warranty claims are generally handled through the point of purchase or directly with the manufacturer.
Support
For technical assistance, troubleshooting beyond the scope of this manual, or inquiries regarding parts and service, please contact:
- The authorized dealer or seller from whom you purchased the product.
- FAAC customer support directly. Refer to the official FAAC website for contact information and additional resources.
When contacting support, please have your product model (FAAC 455D) and ASIN (B00XK4TTBY) readily available.