1. Introduction
This manual provides essential information for the proper setup, operation, and maintenance of your Invacare Softform Premier Bariatric Mattress. Please read this manual thoroughly before using the product to ensure safe and effective use.
The Invacare Softform Premier Bariatric Mattress is designed for bariatric individuals at high risk of pressure ulcers. It features a unique single-piece U-core foam construction for enhanced durability and built-in side supports to facilitate easier transfers for both users and caregivers.
2. Key Features
- Contoured Foam Insert: Provides excellent individual comfort and optimizes pressure reduction for individuals up to very high risk.
- Single Piece U-Core Foam: Enhances durability and provides side support for easier patient transfers.
- Unique Castellated Cells: Break the surface tensions of the foam, allowing the resident to be immersed into the foam, maximizing body contact area and optimizing pressure reduction.
- Fluid-Resistant, Four-Way Stretch Polyurethane Cover: Features a tough coated polyurethane base for extended longevity. The cover is removable and machine washable.
- Dimensions: 80" Length x 48" Width x 6" Height.
- Weight Capacity: 650 lbs.
3. Setup Instructions
- Unpacking: Carefully remove the mattress from its packaging. Ensure all packaging materials are discarded responsibly.
- Placement: Position the mattress on a suitable bed frame. Ensure the mattress is centered and lies flat on the bed surface.
- Orientation: The mattress is designed for optimal pressure distribution. Ensure the side with the Invacare logo and foot symbols is positioned at the foot end of the bed.
- Cover Inspection: Before first use, inspect the fluid-resistant cover for any signs of damage or tears. If any damage is found, contact Invacare customer support immediately.

Figure 1: Exploded view of the Invacare Softform Premier Bariatric Mattress showing its internal foam layers and outer cover.
4. Operating the Mattress
The Softform Premier Bariatric Mattress is a static pressure redistribution surface. It does not require power or active adjustments during use. Its design inherently provides pressure relief and comfort.
4.1 Patient Positioning
Ensure the patient is positioned centrally on the mattress. The unique castellated cells adapt to the patient's body shape, maximizing contact area and distributing pressure evenly.

Figure 2: Close-up of the high-resiliency foam with mushroom-shaped cells, demonstrating its ability to conform and distribute pressure.
4.2 Patient Transfers
The mattress features a single-piece U-core foam with enhanced side supports. These firm edges facilitate safer and easier patient transfers on and off the bed, reducing the risk of falls.

Figure 3: The mattress design includes effective side-wall support, aiding in patient transfers and stability.
5. Maintenance and Cleaning
5.1 Cover Care
The mattress cover is fluid-resistant and designed for easy cleaning. It is fully removable for laundering and inspection of the foam core.

Figure 4: The mattress features a fully removable cover, allowing for easy cleaning and inspection of the foam.
- Cleaning: Wipe the cover with a damp cloth and mild detergent. For deeper cleaning, the cover can be machine washed. Refer to the care label on the cover for specific washing instructions (e.g., maximum temperature 176°F).
- Drying: Air dry or tumble dry on low heat. Ensure the cover is completely dry before re-installing it on the mattress.
- Inspection: Regularly inspect the cover for any signs of wear, tears, or damage. A damaged cover can compromise the mattress's fluid resistance and pressure redistribution properties.

Figure 5: The premium fluid-resistant cover protects the mattress and is designed for durability and hygiene.
5.2 Foam Core Care
The foam core itself should not be washed. If the foam becomes soiled, spot clean with a mild disinfectant and allow to air dry completely before replacing the cover.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Mattress feels too firm or too soft. | Incorrect patient weight for mattress type; improper bed frame support. | Ensure patient weight is within the 650 lbs capacity. Verify bed frame provides even support. |
| Cover is damaged or torn. | Wear and tear; sharp objects. | Replace the cover immediately to maintain fluid resistance and hygiene. Contact Invacare for replacement parts. |
| Unusual odors from mattress. | Fluid ingress into foam; inadequate cleaning. | Remove cover, inspect foam for moisture. Clean foam with mild disinfectant and allow to air dry completely. Ensure cover is properly sealed. |
7. Specifications
- Model Number: IPM1080B48
- Dimensions (L x W x H): 80" x 48" x 6"
- Weight Capacity: 650 lbs
- Mattress Type: Static Pressure Redistribution
- Foam Type: Single piece U-core, High-Resiliency Foam
- Cover Material: Fluid-resistant, Four-way stretch Polyurethane
- Country of Origin: United Kingdom
- Package Dimensions: 61.75 x 12 x 12 inches; 41.7 Pounds
8. Warranty and Support
For warranty information, technical support, or to order replacement parts, please contact Invacare Customer Service.
Invacare Customer Service: 1 (800) 333-6900
You can also visit the official Invacare website for additional resources and product information: www.invacare.com
For the latest digital content and product information, please refer to the official Invacare YouTube channel: www.youtube.com/invacarecorp
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.