True TRUE988284

True 988284 Temperature Control Kit 077B6856 Instruction Manual

Model: TRUE988284

1. Product Overview

The True 988284 Temperature Control Kit 077B6856 is a genuine Original Equipment Manufacturer (OEM) replacement part designed for True Refrigeration units. This kit ensures the proper regulation of temperature within your commercial refrigeration equipment, maintaining optimal operating conditions for safety, reliability, and performance.

True 988284 Temperature Control Kit with dial and capillary tube

Image 1.1: Overview of the True 988284 Temperature Control Kit, showing the control unit, dial, and capillary tube.

Key Features:

  • Genuine OEM replacement part for True Refrigeration.
  • Designed for safety, reliability, and performance.
  • Ensures accurate temperature regulation.
  • Approved by the original equipment manufacturer.

2. Safety Information

Important: Read all instructions carefully before installation or operation. Failure to follow these instructions may result in property damage, personal injury, or death.

  • Electrical Hazard: Always disconnect power to the refrigeration unit before attempting any installation, maintenance, or repair.
  • Qualified Personnel: Installation and servicing should only be performed by qualified and authorized service personnel.
  • Genuine Parts: Use only genuine OEM parts for replacements to ensure compatibility, safety, and optimal performance.
  • Intended Use: This temperature control kit is intended solely for its specified designed usage within True Refrigeration equipment. Do not use for any other purpose.
  • Capillary Tube: Handle the capillary tube with care. Do not bend sharply or kink, as this can damage the sensor and affect performance.

3. Package Contents

Verify that all components are present and undamaged upon opening the package.

Components of the True 988284 Temperature Control Kit including control unit, dial, screws, and connectors

Image 3.1: Contents of the True 988284 Temperature Control Kit, typically including the control module, temperature dial, mounting screws, and electrical connectors.

  • Temperature Control Module with Capillary Tube
  • Temperature Adjustment Dial
  • Mounting Screws (typically 2)
  • Electrical Connectors (typically 2)
  • Instruction Sheet (if included by manufacturer)

4. Installation Instructions

This section provides general guidance for replacing a temperature control kit. Specific installation steps may vary depending on your True Refrigeration model. Refer to your unit's service manual for detailed, model-specific instructions.

  1. Disconnect Power: Locate the main power supply to the refrigeration unit and disconnect it. Verify that power is off using a voltage tester.
  2. Access Control Area: Depending on your unit, you may need to remove access panels or grilles to reach the existing temperature control.
  3. Document Wiring: Before disconnecting any wires, take clear photos or make a diagram of the existing wiring connections to the old temperature control. Note the position of the capillary tube sensor.
  4. Remove Old Control:
    • Carefully disconnect the electrical wires from the old control.
    • Unmount the old control from its housing.
    • Gently remove the capillary tube sensor from its sensing location (e.g., evaporator coil, air return).
  5. Install New Control:
    • Insert the new capillary tube sensor into the exact same sensing location as the old one. Ensure it is securely positioned for accurate temperature readings. Avoid kinking or damaging the tube.
    • Mount the new temperature control module in the same position as the old one using the provided screws.
    • Connect the electrical wires to the new control according to your documented wiring diagram. Ensure connections are secure.
  6. Reassemble: Replace any access panels or grilles that were removed.
  7. Restore Power: Reconnect the main power supply to the refrigeration unit.
  8. Test Operation: Allow the unit to run for a period and monitor the temperature to ensure proper operation and temperature regulation. Adjust the dial as needed.

Note: If you are unsure about any step, consult a qualified refrigeration technician.

5. Operating Instructions

The temperature control kit features a rotary dial for adjusting the desired temperature within your True Refrigeration unit.

  • Temperature Adjustment: Rotate the dial to select the desired temperature setting. Typically, rotating towards "Colder" or higher numbers (e.g., 6, 7, 8) will decrease the temperature, while rotating towards "Warmer" or lower numbers (e.g., 1, 2, 3) will increase it.
  • Monitoring: After adjusting the setting, allow several hours for the refrigeration unit to stabilize at the new temperature. Use an independent thermometer to verify the internal temperature.
  • Optimal Setting: The optimal setting will depend on the specific refrigeration unit and the products being stored. Adjust incrementally until the desired temperature range is consistently maintained.

6. Maintenance

The True 988284 Temperature Control Kit is designed for durability and reliability. Regular maintenance of the overall refrigeration unit is crucial for its longevity and efficient operation.

  • Periodic Inspection: Periodically inspect the control module and its wiring for any signs of wear, corrosion, or loose connections.
  • Capillary Tube: Ensure the capillary tube remains securely in its sensing location and is not damaged or kinked.
  • Cleaning: Keep the area around the temperature control free from dust and debris. Use a soft, dry cloth for cleaning. Do not use harsh chemicals or abrasive cleaners.
  • Professional Check: Consider annual professional maintenance checks for your refrigeration unit, which should include inspection of the temperature control system.

7. Troubleshooting

If your refrigeration unit is experiencing temperature issues after installing this kit, consider the following common troubleshooting steps:

ProblemPossible CauseSolution
Unit not cooling or too warm
  • Temperature dial set too high (warmer)
  • Capillary tube not properly seated or damaged
  • Loose electrical connection
  • Other refrigeration system issues (e.g., low refrigerant, dirty condenser)
  • Adjust dial to a colder setting.
  • Verify capillary tube placement and condition.
  • Check and secure all wiring connections (with power disconnected).
  • Consult a qualified technician for system diagnosis.
Unit freezing contents or too cold
  • Temperature dial set too low (colder)
  • Capillary tube sensing incorrect temperature (e.g., too close to evaporator)
  • Control unit malfunction
  • Adjust dial to a warmer setting.
  • Ensure capillary tube is correctly positioned away from direct evaporator contact if applicable.
  • If issues persist, the control unit may require replacement or further diagnosis by a technician.
Temperature fluctuates widely
  • Improper capillary tube placement
  • Control unit malfunction
  • Refrigeration system issues
  • Verify capillary tube placement.
  • Consult a qualified technician for diagnosis.

Warning: Do not attempt repairs beyond your technical capabilities. Always prioritize safety and consult a professional for complex issues.

8. Specifications

FeatureDetail
BrandTrue
Model NumberTRUE988284
Product Dimensions6 x 6 x 4 inches
Item Weight4.8 ounces
Operation ModeAutomatic
Contact TypeNormally Open
Connector TypeScrew Terminals
TerminalScrew
Circuit Type1-way
Mounting TypeSurface Mount
Actuator TypePush Button
Contact MaterialCopper, Brass
Date First AvailableJune 15, 2011

9. Warranty and Support

As a genuine OEM part, this True 988284 Temperature Control Kit is manufactured to high standards. For specific warranty information, please refer to the documentation provided with your original True Refrigeration unit or contact True Refrigeration directly.

Customer Support:

For technical assistance, troubleshooting beyond this manual, or to inquire about warranty claims, please contact True Refrigeration customer support or an authorized service provider.

  • Manufacturer: True
  • Website: www.truemfg.com
  • Model Number: TRUE988284
  • Part Number: 988284, 077B6856

© 2025 True Refrigeration. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.