True TRUE988284

True 988284 Temperature Control Kit 077B6856 Instruction Manual

Model: TRUE988284

1. Product Overview

The True 988284 Temperature Control Kit 077B6856 is a genuine Original Equipment Manufacturer (OEM) replacement part designed for True Refrigeration units. This kit ensures the proper regulation of temperature within your commercial refrigeration equipment, maintaining optimal operating conditions for safety, reliability, and performance.

True 988284 Temperature Control Kit with dial and capillary tube

Image 1.1: Overview of the True 988284 Temperature Control Kit, showing the control unit, dial, and capillary tube.

Key Features:

2. Safety Information

Important: Read all instructions carefully before installation or operation. Failure to follow these instructions may result in property damage, personal injury, or death.

3. Package Contents

Verify that all components are present and undamaged upon opening the package.

Components of the True 988284 Temperature Control Kit including control unit, dial, screws, and connectors

Image 3.1: Contents of the True 988284 Temperature Control Kit, typically including the control module, temperature dial, mounting screws, and electrical connectors.

4. Installation Instructions

This section provides general guidance for replacing a temperature control kit. Specific installation steps may vary depending on your True Refrigeration model. Refer to your unit's service manual for detailed, model-specific instructions.

  1. Disconnect Power: Locate the main power supply to the refrigeration unit and disconnect it. Verify that power is off using a voltage tester.
  2. Access Control Area: Depending on your unit, you may need to remove access panels or grilles to reach the existing temperature control.
  3. Document Wiring: Before disconnecting any wires, take clear photos or make a diagram of the existing wiring connections to the old temperature control. Note the position of the capillary tube sensor.
  4. Remove Old Control:
    • Carefully disconnect the electrical wires from the old control.
    • Unmount the old control from its housing.
    • Gently remove the capillary tube sensor from its sensing location (e.g., evaporator coil, air return).
  5. Install New Control:
    • Insert the new capillary tube sensor into the exact same sensing location as the old one. Ensure it is securely positioned for accurate temperature readings. Avoid kinking or damaging the tube.
    • Mount the new temperature control module in the same position as the old one using the provided screws.
    • Connect the electrical wires to the new control according to your documented wiring diagram. Ensure connections are secure.
  6. Reassemble: Replace any access panels or grilles that were removed.
  7. Restore Power: Reconnect the main power supply to the refrigeration unit.
  8. Test Operation: Allow the unit to run for a period and monitor the temperature to ensure proper operation and temperature regulation. Adjust the dial as needed.

Note: If you are unsure about any step, consult a qualified refrigeration technician.

5. Operating Instructions

The temperature control kit features a rotary dial for adjusting the desired temperature within your True Refrigeration unit.

6. Maintenance

The True 988284 Temperature Control Kit is designed for durability and reliability. Regular maintenance of the overall refrigeration unit is crucial for its longevity and efficient operation.

7. Troubleshooting

If your refrigeration unit is experiencing temperature issues after installing this kit, consider the following common troubleshooting steps:

ProblemPossible CauseSolution
Unit not cooling or too warm
  • Temperature dial set too high (warmer)
  • Capillary tube not properly seated or damaged
  • Loose electrical connection
  • Other refrigeration system issues (e.g., low refrigerant, dirty condenser)
  • Adjust dial to a colder setting.
  • Verify capillary tube placement and condition.
  • Check and secure all wiring connections (with power disconnected).
  • Consult a qualified technician for system diagnosis.
Unit freezing contents or too cold
  • Temperature dial set too low (colder)
  • Capillary tube sensing incorrect temperature (e.g., too close to evaporator)
  • Control unit malfunction
  • Adjust dial to a warmer setting.
  • Ensure capillary tube is correctly positioned away from direct evaporator contact if applicable.
  • If issues persist, the control unit may require replacement or further diagnosis by a technician.
Temperature fluctuates widely
  • Improper capillary tube placement
  • Control unit malfunction
  • Refrigeration system issues
  • Verify capillary tube placement.
  • Consult a qualified technician for diagnosis.

Warning: Do not attempt repairs beyond your technical capabilities. Always prioritize safety and consult a professional for complex issues.

8. Specifications

FeatureDetail
BrandTrue
Model NumberTRUE988284
Product Dimensions6 x 6 x 4 inches
Item Weight4.8 ounces
Operation ModeAutomatic
Contact TypeNormally Open
Connector TypeScrew Terminals
TerminalScrew
Circuit Type1-way
Mounting TypeSurface Mount
Actuator TypePush Button
Contact MaterialCopper, Brass
Date First AvailableJune 15, 2011

9. Warranty and Support

As a genuine OEM part, this True 988284 Temperature Control Kit is manufactured to high standards. For specific warranty information, please refer to the documentation provided with your original True Refrigeration unit or contact True Refrigeration directly.

Customer Support:

For technical assistance, troubleshooting beyond this manual, or to inquire about warranty claims, please contact True Refrigeration customer support or an authorized service provider.

Related Documents - TRUE988284

Preview True Kommerzielle Kühltechnik: Allgemeiner Regelungsleitfaden
Umfassender Leitfaden zur Bedienung, Einstellung und Fehlerbehebung von Temperaturregelungen in True kommerziellen Kühl- und Gefriergeräten. Enthält Anleitungen für mechanische und elektronische Steuerungen sowie spezifische Modellinformationen.
Preview TRUE Manufacturing Installation Manual Quick Start Guide
This document provides essential installation, operation, and maintenance guidelines for TRUE Manufacturing commercial refrigeration and heating appliances. It includes safety warnings, specifications, setup procedures, and care instructions.
Preview True TH Models Heated Cabinets Installation Manual
Comprehensive installation, operation, and maintenance guide for True TH Models heated cabinets. Covers safety, electrical, setup, care, and warranty information from True Manufacturing Co., Inc.
Preview True T-23DF-HC Commercial Refrigerator/Freezer Installation and Operation Manual
Comprehensive installation, operation, maintenance, and safety guide for the True T-23DF-HC dual-chamber commercial refrigerator/freezer. Includes troubleshooting, cleaning instructions, and warranty information.
Preview True CVM Series Installation Manual
Comprehensive installation, operation, and maintenance manual for True CVM series refrigeration units. Covers safety precautions, electrical requirements, installation procedures, leveling, sealing, shelf mounting, and general maintenance.
Preview Manuel d'Installation et de Démarrage Rapide True
Guide complet pour l'installation, l'utilisation et l'entretien des appareils de réfrigération et de congélation True Manufacturing Co., Inc. Inclut des informations de sécurité essentielles et des ressources pour le support.