FERVE F-807
FERVE F-807 Lead Acid Battery Charger
User Manual
Introduction
This manual provides detailed instructions for the safe and efficient operation of your FERVE F-807 Lead Acid Battery Charger. The F-807 is designed to charge all types of lead-acid batteries, supporting both 12-volt and 24-volt systems, with selectable charging currents of 4 amps and 8 amps. Please read this manual thoroughly before first use to ensure proper functionality and safety.
Important Safety Instructions
- Always connect the charger to the battery before plugging it into the mains power supply.
- Disconnect the mains power supply before disconnecting the charger from the battery.
- Ensure adequate ventilation when charging batteries, as they can produce explosive gases.
- Avoid open flames or sparks near the battery during charging.
- Wear eye protection and gloves when handling batteries.
- Do not expose the charger to rain or excessive moisture.
- Keep out of reach of children.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
Product Features
- Premium Charger for 12V and 24V lead-acid batteries.
- Selectable charging currents: 4 Amps and 8 Amps.
- Suitable for batteries with a capacity between 24 Ah and 95 Ah.
- Integrated analog Ammeter for charge indication.
- Robust metal casing for durability.
Product Components

Figure 1: Front view of the FERVE F-807 Battery Charger, showing the analog ammeter, voltage and current selector switches, and battery clamps.
- Analog Ammeter: Displays the charging current in DC Amps.
- Current Selector Switch (4A/8A): Allows selection of the desired charging current.
- Voltage Selector Switch (12V/24V): Allows selection of the battery voltage to be charged.
- Positive (+) Battery Clamp (Red): Connects to the positive terminal of the battery.
- Negative (-) Battery Clamp (Black): Connects to the negative terminal of the battery.
- Mains Power Cord: Connects the charger to the AC power supply.
- Robust Metal Casing: Protects internal components.
Setup and Initial Connection
- Preparation: Ensure the battery is in a well-ventilated area. Check the battery terminals for corrosion and clean them if necessary.
- Charger Placement: Place the charger on a stable, dry surface, away from direct sunlight or heat sources.
- Voltage Selection: Before connecting, set the Voltage Selector Switch (12V/24V) on the charger to match the voltage of the battery you intend to charge. Incorrect voltage selection can damage the battery or charger.
- Current Selection: Set the Current Selector Switch (4A/8A) to the desired charging current. For smaller batteries or slower charging, select 4A. For larger batteries or faster charging, select 8A. Refer to your battery's specifications for recommended charging rates.
- Connect Positive Clamp: Connect the RED (+) battery clamp to the positive terminal of the battery.
- Connect Negative Clamp: Connect the BLACK (-) battery clamp to the negative terminal of the battery.
- Connect to Mains Power: Only after both battery clamps are securely connected, plug the charger's mains power cord into a suitable AC power outlet (230V~50/60Hz).
Operating the Charger
- Once connected to the battery and mains power, the charger will begin charging.
- Monitor the Analog Ammeter on the front panel. The needle will indicate the charging current. As the battery charges, the current will gradually decrease.
- Charging time varies depending on the battery's capacity and discharge level. A fully discharged 95Ah battery charged at 8A will take approximately 12 hours to reach full charge.
- When the ammeter needle drops to a very low reading (near 0-1 Amp), the battery is nearing full charge. For optimal battery life, it is recommended to disconnect the charger once the battery is fully charged.
- Disconnection Procedure:
- First, unplug the charger from the mains power outlet.
- Next, disconnect the BLACK (-) battery clamp from the negative terminal.
- Finally, disconnect the RED (+) battery clamp from the positive terminal.
Maintenance and Storage
- Cleaning: Disconnect the charger from all power sources before cleaning. Wipe the casing with a dry or slightly damp cloth. Do not use harsh chemicals or abrasive cleaners.
- Cable Inspection: Regularly inspect the power cord and battery cables for any signs of damage, fraying, or exposed wires. Do not use the charger if any cables are damaged.
- Storage: Store the charger in a cool, dry place, away from direct sunlight and extreme temperatures. Keep it in its original packaging or a protective container to prevent dust accumulation.
- Battery Care: Ensure battery terminals are clean and free of corrosion for efficient charging.
Troubleshooting Guide
| Problem | Possible Cause | Solution |
|---|---|---|
| Charger not turning on / No Ammeter reading | No mains power; Incorrect connection; Blown fuse (internal) | Check power outlet; Ensure clamps are correctly connected to battery terminals; Contact qualified service personnel for fuse replacement. |
| Ammeter reading is very low or zero, but battery is not fully charged | Battery is deeply discharged; Incorrect voltage selection; Poor connection | Allow more time for charging; Verify voltage switch matches battery; Clean battery terminals and re-secure clamps. |
| Charger gets excessively hot | Poor ventilation; Overload; Internal fault | Ensure adequate airflow around charger; Check battery capacity is within charger's range (24-95Ah); Discontinue use and contact service. |
| Battery not charging or taking too long | Battery is faulty; Incorrect current selection; Battery capacity too high | Have battery tested by a professional; Ensure 8A is selected for faster charging if appropriate; Confirm battery capacity is within 24-95Ah. |
Technical Specifications
| Model Number | F-807 |
| Brand | FERVE |
| Input Voltage | 230V ~ 50/60Hz |
| Output Voltage | 12V / 24V DC (Selectable) |
| Charging Current | 4A / 8A (Selectable) |
| Power Consumption | 210W |
| Battery Capacity Range | 24 Ah - 95 Ah |
| Product Dimensions (L x W x H) | 21 x 18 x 12.5 cm |
| Item Weight | 4.23 kg |
| Manufacturer | FERVE, S.A. |
Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact FERVE customer service directly. Keep your proof of purchase for any warranty claims.
For further assistance, please visit the official FERVE website or contact your local distributor.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.