1. Introduction
This user manual provides comprehensive instructions for the proper installation, operation, and maintenance of the Pitco B7510084-C Sg14/18 Conversion Kit. This kit is specifically designed to facilitate the conversion of Pitco Sg14/18 series fryers from natural gas (NAT) to liquid propane (LP) operation. Adherence to these instructions is crucial for safe and efficient use of the converted appliance.
2. Product Description
The Pitco B7510084-C is a genuine OEM replacement part engineered for converting specific Pitco fryer models. It includes the necessary components, such as orifices and valve parts, to adjust the gas flow and pressure for safe and effective operation with liquid propane. Using genuine OEM parts ensures compatibility, safety, reliability, and optimal performance of your equipment.

Figure 2.1: Pitco B7510084-C Sg14/18 Conversion Kit Components. This image displays the various parts included in the conversion kit, such as multiple brass gas orifices, a black plastic component with a star-shaped opening, a flat black screw-in cap, a coiled red spring, and a cylindrical metal valve component.
3. Safety Information
WARNING: Installation and service of this conversion kit must be performed by a qualified, licensed gas technician in accordance with all local codes and national standards, including NFPA 54/ANSI Z223.1 (National Fuel Gas Code) or CSA B149.1 (Natural Gas and Propane Installation Code). Failure to comply can result in property damage, personal injury, or death.
- Always disconnect the appliance from the gas supply and electrical power before beginning any installation or service.
- Ensure adequate ventilation during and after installation.
- Check all gas connections for leaks using a non-corrosive leak detection solution after installation. Never use an open flame.
- Verify that the converted appliance is correctly labeled for LP gas operation.
- Do not operate the appliance if any gas leaks are detected.
4. Package Contents
Upon opening the package, verify that all components are present and undamaged. The Pitco B7510084-C conversion kit typically includes:
- LP Gas Orifices (multiple, specific sizes for LP)
- Gas Valve Conversion Components (e.g., spring, diaphragm, adjustment screw)
- Instruction Sheet (refer to this manual for detailed steps)
Note: The exact number and type of components may vary slightly based on specific fryer models within the Sg14/18 series.
5. Setup and Installation
IMPORTANT: This procedure must be performed by a qualified service technician.
- Preparation:
- Ensure the fryer is completely cooled down.
- Disconnect the fryer from the main gas supply and electrical power.
- Remove any access panels or covers necessary to reach the gas manifold and valve assembly.
- Remove Existing Components:
- Carefully remove the existing natural gas orifices from the burners.
- Disassemble the natural gas valve components as per the specific fryer service manual, replacing them with the LP conversion kit parts (e.g., spring, diaphragm, adjustment screw).
- Install LP Components:
- Install the new LP gas orifices into the burners, ensuring they are securely tightened.
- Assemble the LP gas valve components according to the fryer's service manual and the kit's instructions.
- Reassembly and Labeling:
- Reinstall all access panels and covers.
- Affix the provided LP conversion label prominently on the fryer, indicating that it has been converted for use with liquid propane.
- Leak Testing:
- Reconnect the fryer to the LP gas supply.
- Perform a thorough leak test on all new and disturbed gas connections using a non-corrosive leak detection solution. Bubbles indicate a leak.
- If leaks are detected, shut off the gas supply immediately and rectify the connection before proceeding.
- Pressure Adjustment:
- Adjust the gas pressure regulator to the correct LP operating pressure as specified in the fryer's service manual.
6. Operating Instructions (Post-Conversion)
After successful conversion and leak testing, the fryer is ready for operation with liquid propane. Always ensure the fryer is connected to the correct gas type (LP) before ignition.
- Initial Ignition: Follow the standard ignition procedure outlined in your fryer's original operating manual.
- Flame Appearance: Observe the burner flames. They should be predominantly blue with minimal yellow tipping, indicating proper combustion. If flames are excessively yellow or noisy, consult a qualified technician.
- Performance Check: Monitor the fryer's heating performance to ensure it reaches and maintains desired temperatures efficiently.
7. Maintenance
Regular maintenance ensures the longevity and safe operation of your converted fryer.
- Annual Inspection: Have a qualified technician inspect the gas connections, orifices, and valve components annually for wear, corrosion, or leaks.
- Cleaning: Keep the area around the burners and gas components clean and free of grease buildup.
- Component Replacement: Replace any worn or damaged components with genuine Pitco OEM parts only.
8. Troubleshooting
If you encounter issues after converting your fryer, consider the following common troubleshooting steps. For complex issues, always contact a qualified service technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Burners not igniting or weak flame | Incorrect gas pressure; clogged LP orifices; gas supply issue; faulty igniter. | Verify LP gas supply and pressure. Check orifices for blockages. Consult technician for igniter or valve issues. |
| Yellow or sooty flames | Improper air/gas mixture; incorrect LP orifices; gas pressure too high. | Ensure correct LP orifices are installed. Have a technician adjust air shutter or gas pressure. |
| Smell of gas | Gas leak. | Immediately shut off gas supply. Ventilate area. Do not operate. Contact qualified technician. |
9. Specifications
| Attribute | Detail |
|---|---|
| Model Number | PTB7510084-C |
| Product Dimensions | 9 x 6 x 5 inches |
| Item Weight | 1.28 ounces |
| Compatibility | Pitco Sg14/18 series fryers (NAT to LP conversion) |
| Country of Origin | United States |
10. Warranty and Support
This Pitco B7510084-C conversion kit is a genuine OEM part, designed for durability and performance. For specific warranty information, please refer to the original purchase documentation or contact Pitco customer support directly. Pitco stands behind the quality of its genuine parts.
For technical assistance, parts inquiries, or to locate a qualified service technician, please visit the official Pitco website or contact their customer service department. Always provide your product model number (PTB7510084-C) and the fryer's serial number when seeking support.
Pitco Official Website: www.pitco.com