Orbis OB050623

ORBIS CRONO QRD 230V Surface-Mounted Analogue Timer

Model: OB050623

Instruction Manual

1. Introduction

Thank you for choosing the ORBIS CRONO QRD 230V Surface-Mounted Analogue Timer. This device is designed to control electrical circuits based on a programmed time schedule. It is suitable for various applications requiring automated switching of electrical loads. Please read this manual carefully before installation and operation to ensure safe and efficient use of the product.

2. Safety Information

WARNING: Electrical installation should only be performed by a qualified electrician in accordance with all local and national electrical codes. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always disconnect power at the main circuit breaker before installing or servicing the timer.
  • Ensure the timer's voltage and current ratings are compatible with your electrical system and the load it will control. This timer is rated for 230V / 250V AC.
  • Do not install in wet or damp locations unless specifically rated for such environments.
  • Do not exceed the maximum load rating of the timer.
  • Keep children away from electrical installations.

3. Package Contents

  • 1 x ORBIS CRONO QRD 230V Surface-Mounted Analogue Timer (Model OB050623)
  • 1 x Instruction Manual (this document)

4. Product Overview

The ORBIS CRONO QRD is an analogue surface-mounted timer designed for reliable time-based switching. It features a robust plastic housing and a clear dial for setting daily programs.

ORBIS CRONO QRD 230V Surface-Mounted Analogue Timer, front view showing the dial and housing.

Figure 1: Front view of the ORBIS CRONO QRD Analogue Timer. This image shows the main dial for time setting and the overall surface-mounted design.

5. Setup and Installation

This timer is designed for surface mounting. Ensure the mounting surface is stable and suitable for electrical installations.

  1. Power Disconnection: Before beginning any installation, ensure the main power supply to the circuit is turned off at the circuit breaker. Verify with a voltage tester.
  2. Mounting Location: Choose a suitable, dry, and easily accessible location for mounting the timer. Mark the drilling points for the mounting screws.
  3. Secure Mounting: Drill pilot holes if necessary and securely fasten the timer to the surface using appropriate screws.
  4. Wiring:
    • Open the terminal cover of the timer.
    • Connect the incoming live (L) and neutral (N) wires to the designated input terminals.
    • Connect the live (L') and neutral (N') wires of the load (e.g., light fixture, appliance) to the designated output terminals.
    • Ensure all connections are tight and secure. Refer to the wiring diagram inside the timer's terminal cover for precise connections.
  5. Close Cover: Replace the terminal cover securely.
  6. Power Restoration: Restore power at the main circuit breaker.

6. Operating Instructions

The CRONO QRD timer operates on a 24-hour analogue dial system.

  1. Set Current Time: Rotate the outer dial clockwise until the current time aligns with the small arrow or marker on the timer's body. The dial typically has markings for hours (e.g., 0-24) and possibly minutes.
  2. Program ON/OFF Times: The dial is surrounded by small segments or pins.
    • To set an "ON" period, push the corresponding segments/pins outwards.
    • To set an "OFF" period, leave the segments/pins pushed inwards.
    • Each segment typically represents a specific time interval (e.g., 15 minutes).
  3. Manual Override (if applicable): Some models may include a manual override switch (e.g., ON/AUTO/OFF). Set this switch to "AUTO" for programmed operation. Use "ON" or "OFF" for continuous operation or to temporarily disable the timer.
  4. Verification: Observe the timer's operation over a short period to ensure it switches the load ON and OFF according to your programmed schedule.

7. Maintenance

The ORBIS CRONO QRD timer requires minimal maintenance.

  • Cleaning: Disconnect power before cleaning. Wipe the exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Inspection: Periodically check for any signs of damage, loose connections, or overheating. If any issues are observed, disconnect power and consult a qualified electrician.

8. Troubleshooting

Problem Possible Cause Solution
Timer not switching load ON/OFF.
  • No power to the timer.
  • Incorrect programming.
  • Manual override switch in wrong position.
  • Faulty wiring.
  • Check circuit breaker and power connections.
  • Review Section 6: Operating Instructions and re-program.
  • Set manual override to "AUTO".
  • Consult a qualified electrician to check wiring.
Timer dial not moving.
  • No power to the timer.
  • Internal mechanical fault.
  • Check power supply.
  • Contact customer support or a qualified technician.

If the problem persists after attempting these solutions, please contact ORBIS customer support or a qualified electrician.

9. Specifications

Brand Orbis
Model Number OB050623
Type Analogue Surface-Mounted Timer
Voltage Rating 230 V / 250 V AC
Material Plastic
Item Weight 0.5 Kilograms (1.1 pounds)
Number of Settings 1 (referring to one daily program cycle)
Product Dimensions 4.09 x 2.83 x 2.89 inches
Manufacturer ORBIS Zeitschalttechnik
ASIN B00WEE8K3E

10. Warranty and Support

Specific warranty details for the ORBIS CRONO QRD timer are typically provided with the product packaging or can be obtained from your point of purchase. For technical support, warranty claims, or further assistance, please contact ORBIS Zeitschalttechnik directly or refer to their official website.

Manufacturer: ORBIS Zeitschalttechnik

Please retain your proof of purchase for warranty purposes.

© 2026 ORBIS Zeitschalttechnik. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.