1. Introduction
The Paradox Spectra SP4000 is a sophisticated microprocessor-based control panel designed for security systems. It offers a robust solution for managing wired and wireless security zones, providing comprehensive protection for various environments. This manual provides essential information for the proper setup, operation, and maintenance of your SP4000 system.
2. Key Features
- 4 wired zones, expandable to 8 with dual zone function, and up to 32 zones wired/wireless.
- Supports up to 15 zones on the keyboard (1 per keyboard).
- Memory module for 256 events.
- Supports 32 user codes and remote controls.
- Ability to quickly occupy open zones.
- System can be divided into 2 independent areas with a common space.
- Built-in Digital Selector: 3 numbers for cameras and 5 digits for voice control (with VDMP3).
- Automatic operation for summer and winter time adjustments.
- Direct connection to 9.6K construction with BabyWare software.
- 1 programming output, expandable to 10.
- 1 relay output.
- 32 zone expandability with bus expander modules.
- Power supply: 1.1 A.
- Durable metal cabinet with dimensions 280 x 280 x 76 mm.
- Compatible with various Paradox keypads and modules including TM50, K32LCD, K32I, K32, K10H, K10V, K32LX, K32LX/86, VDMP3, PCS250, IP100, and IP150.
- Local firmware updates via 307USB interface and BabyWare software.
- Simplified programming with menus.
- Features MODUS operation mode Stay D.
- Compatible with RTX1 and RTX3 receivers.
- Corresponds to EN50131 step 2 standards.
3. Setup
Proper installation is crucial for the reliable operation of your Paradox Spectra SP4000. It is recommended that installation be performed by a qualified security professional.
3.1 Unpacking and Inspection
Carefully unpack all components and inspect them for any signs of damage. Ensure all items listed in the packing list are present.
3.2 Mounting the Control Panel
The SP4000 comes in a metal cabinet designed for secure mounting. Choose a dry, secure, and easily accessible location, typically indoors, away from extreme temperatures and moisture. Secure the cabinet firmly to a wall using appropriate fasteners.

Figure 1: Paradox Spectra SP4000 Microprocessor Control Panel Circuit Board. An image showing the green circuit board of the Paradox Spectra SP4000 microprocessor control panel, mounted within its metal enclosure. The board features various electronic components, connectors for wired zones, and power inputs. The Paradox Security Systems logo and website are visible on the enclosure.
3.3 Wiring Connections
Connect all necessary wiring, including power, wired zones, keypads, and communication modules, according to the detailed wiring diagrams provided in the full installation guide (not included in this manual). Ensure all connections are secure and correctly terminated to prevent system malfunctions.
3.4 Initial Power-Up and Configuration
Once all wiring is complete, apply power to the control panel. Follow the initial programming steps using a compatible keypad or the BabyWare software to configure zones, user codes, communication settings, and other system parameters. Refer to the specific programming manual for detailed instructions.
4. Operating the System
The Paradox Spectra SP4000 system is operated primarily through connected keypads or remote controls. Familiarize yourself with the functions of your specific keypad model.
4.1 Arming and Disarming
To arm the system, enter your user code followed by the arming command (e.g., STAY, ARM). To disarm, enter your user code. The system provides options for full arming, stay arming (for when occupants are present), and night arming for individual zones.
4.2 Zone Management
The system allows for individual zone bypass, enabling you to temporarily disable specific zones without disarming the entire system. This is useful for maintenance or when a zone is intentionally left open.
4.3 User Codes and Access
Manage user codes through the keypad programming menu. Each user can be assigned a unique code with specific access levels and permissions. Remote controls can also be programmed for convenient arming and disarming.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your SP4000 system.
- Regular Checks: Periodically inspect all wiring connections for signs of wear or damage. Ensure the control panel and associated devices are free from dust and debris.
- Battery Backup: If your system includes a backup battery, ensure it is functioning correctly and replace it as recommended by the manufacturer (typically every 3-5 years).
- Software Updates: Keep the system firmware updated using the 307USB interface and BabyWare software to benefit from the latest features and security enhancements.
- Professional Inspection: Schedule annual inspections by a qualified security technician to ensure all components are functioning correctly and to address any potential issues.
6. Troubleshooting
This section provides general guidance for common issues. For complex problems, contact a qualified technician.
- No Power: Check the main power supply and circuit breaker. Ensure all power connections to the control panel are secure.
- Zone Faults: If a zone shows a fault, check the sensor and wiring for that specific zone. Ensure windows and doors are closed if they are part of the zone.
- Communication Issues: If the system fails to communicate with the monitoring station or remote modules, verify network connections (for IP modules) or SIM card status (for GSM modules).
- Keypad Not Responding: Check the keypad's power and data connections to the control panel.
Always refer to the detailed troubleshooting section in the full installation manual or contact Paradox technical support for specific error codes and solutions.
7. Specifications
| Attribute | Value |
|---|---|
| Manufacturer | PARADOX Security Systems |
| Part Number | SP4000 |
| Package Dimensions | 27.2 x 26 x 9.6 cm |
| Item Weight | 2.18 kg |
| Material | Metal |
| Power Source Type | Mains Powered |
| Item Package Quantity | 1 |
| Batteries Included? | No |
| Batteries Required? | No |
| Connectivity Technology | Wired, Wireless |
| Date First Available | 25 Nov. 2015 |
8. Warranty and Support
For information regarding product warranty, technical support, or service, please contact your authorized Paradox dealer or visit the official Paradox Security Systems website. Keep your purchase receipt as proof of purchase for warranty claims.