1. Introduction
Thank you for choosing the Rice Lake Versa-Portion RLP-6S Washdown Portable Scale. This manual provides essential information for the proper setup, operation, and maintenance of your scale. Designed for precision and durability, the RLP-6S is a compact bench scale ideal for various weighing applications, particularly in environments requiring frequent cleaning.
The RLP-6S features a robust stainless steel housing and platform, an easy-to-read LED display, and a capacity of 6 lb (3000g) with a readability of 0.002 lb (1g). It is NTEP certified (CC 10-068, Class III 3000d) and Measurement Canada approved (AM-5794, Class III 3000D), ensuring reliable and accurate measurements.
2. Safety Information
Please read and understand all safety warnings and operating instructions before using this scale. Failure to do so may result in injury or damage to the equipment.
- Power Source: Use only the supplied AC adapter or approved batteries. Ensure the power outlet matches the adapter's specifications.
- Environment: Operate the scale on a stable, level surface. Avoid extreme temperatures, high humidity, and direct sunlight. While the scale is washdown capable, do not submerge the entire unit in water.
- Handling: Do not drop the scale or subject it to excessive shock. Avoid placing objects heavier than the maximum capacity (6 lb / 3000g) on the platform.
- Cleaning: Disconnect power before cleaning. Use mild detergents and avoid abrasive cleaners or solvents that could damage the finish or internal components.
- Maintenance: Refer all servicing to qualified personnel. Do not attempt to open or repair the scale yourself.
3. Setup
Follow these steps to set up your Rice Lake RLP-6S scale:
- Unpacking: Carefully remove the scale and all accessories from the packaging. Retain the packaging for future transport or storage.
- Placement: Place the scale on a firm, level, and stable surface, free from vibrations. Ensure adequate space around the scale for operation and cleaning.
- Power Connection:
- AC Power: Connect the supplied AC adapter to the power input port on the scale and then plug it into a suitable electrical outlet.
- Battery Power (Optional): If using batteries, ensure they are correctly installed in the battery compartment according to polarity markings.
- Initial Power On: Press the POWER button to turn on the scale. The display will perform a self-test and then show "0.000" or "0.0" depending on the selected unit.
- Leveling: The scale should be level for accurate readings. Check the bubble level (if present) and adjust the feet if necessary.

4. Operating Instructions
This section details the basic functions of your RLP-6S scale.
4.1. Button Functions
- POWER: Turns the scale on or off.
- ZERO / +0+: Sets the display to zero. Use this button to zero out the scale before placing an item, or to re-zero if the display drifts slightly.
- TARE: Used to subtract the weight of a container. Place an empty container on the platform, press TARE, and the display will return to zero. Then add the item to be weighed. The display will show the net weight of the item.
- UNITS: Cycles through available weighing units (e.g., ounces (oz), pounds (lb), grams (g)). The active unit will be indicated on the display.
4.2. Basic Weighing
- Turn on the scale by pressing the POWER button.
- Wait for the display to stabilize at "0.000" or "0.0". If it does not, press the ZERO button.
- Place the item to be weighed gently on the center of the stainless steel platform.
- Read the stable weight displayed on the LED screen.
- To change units, press the UNITS button until the desired unit (oz, lb, or g) is indicated.
4.3. Tare Function
- Turn on the scale and ensure it displays "0.000".
- Place an empty container (e.g., bowl, tray) on the weighing platform. The display will show the container's weight.
- Press the TARE button. The display will return to "0.000" and the "Net" indicator will illuminate, signifying that the container's weight has been tared out.
- Add the substance or item to be weighed into the container. The display will now show only the net weight of the added item.
- To clear the tare, remove the container from the platform. The display will show a negative value equal to the container's weight. Press TARE again to return the display to "0.000".
5. Maintenance
Proper maintenance ensures the longevity and accuracy of your Rice Lake RLP-6S scale.
- Cleaning: The RLP-6S is a washdown scale. Disconnect the AC adapter before cleaning. Use a damp cloth with mild soap or detergent to wipe down the stainless steel platform and housing. Avoid using abrasive pads, harsh chemicals, or solvents. Ensure no liquid enters the display or button areas excessively, despite its washdown design. Allow the scale to air dry completely before reconnecting power.
- Storage: When not in use for extended periods, store the scale in a clean, dry environment, away from direct sunlight and extreme temperatures. If using battery power, remove batteries to prevent leakage.
- Calibration: While the scale is factory calibrated, periodic calibration with certified weights may be necessary to maintain accuracy, especially after significant temperature changes or prolonged use. Refer to the full technical manual or contact Rice Lake support for calibration procedures.
6. Troubleshooting
This section addresses common issues you might encounter with your RLP-6S scale.
| Problem | Possible Cause | Solution |
|---|---|---|
| Scale does not turn on. | No power, faulty AC adapter, dead batteries. | Check AC adapter connection and power outlet. Replace batteries if using battery power. |
| Inaccurate readings or unstable display. | Scale not level, unstable surface, air currents, damaged load cell, calibration required. | Ensure scale is on a level, stable surface. Avoid drafts. Remove any objects touching the platform. If problem persists, contact service. |
| "Err" or other error message on display. | Overload, internal error. | Remove any weight from the platform. Turn the scale off and then on again. If the error persists, contact service. |
| Display shows negative weight after removing item. | Tare function is active. | Press the TARE button again to clear the tare and return to zero. |
If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact Rice Lake customer support or an authorized service technician.
7. Specifications
Key technical specifications for the Rice Lake Versa-Portion RLP-6S scale:
| Specification | Detail |
|---|---|
| Model | RLP-6S |
| Capacity | 6 lb (3000g) |
| Readability / Graduations | 0.002 lb (1g) |
| Display Type | LED |
| Weighing Surface Dimensions | Depth: 7-51/64 in., Width: 9-5/16 in. |
| Overall Dimensions (L x W x H) | 11-13/32 in. x 9-29/32 in. x 5-5/16 in. (Approx. 13.3 x 14.8 x 9.6 inches as per product dimensions) |
| Application Modes | Weigh |
| Power Unit | AC (Battery Optional) |
| Platform Material | ABS Plastic (Stainless Steel platform surface) |
| Housing Material | Stainless Steel, Acrylonitrile Butadiene Styrene |
| Standards / Certifications | NTEP CC 10-068, Class III 3000d; Measurement Canada AM-5794, Class III 3000D |
| Item Weight | 15 Pounds |
| UPC | 639385947220 |
| Manufacturer Part Number | 115125 |
8. Warranty and Support
For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Rice Lake Weighing Systems website. Warranty coverage typically addresses defects in materials and workmanship under normal use.
For technical support, service, or to inquire about calibration services, please contact Rice Lake Weighing Systems directly through their official website or customer service channels. Provide your model number (RLP-6S) and serial number (if applicable) when seeking support.
Rice Lake Weighing Systems Official Website: www.ricelake.com