1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your CATA X-Mart 12 Matic Inox Exhaust Fan. Please read these instructions carefully before using the appliance and retain them for future reference.
The CATA X-Mart 12 Matic Inox is a recessed perimetral bathroom exhaust fan designed for effective ventilation. It features a unique automatic shutter system, a removable screw-less front for easy cleaning, and a streamlined design for improved airflow.
2. Safety Information
WARNING: Failure to follow these safety instructions may result in electric shock, fire, or personal injury.
- Ensure the power supply is disconnected before installation, maintenance, or cleaning.
- Installation must be performed by a qualified electrician in accordance with all local and national electrical codes.
- Do not install the fan in areas where flammable or explosive gases may be present.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Keep children away from the appliance.
- Do not operate the fan if any part is damaged. Contact qualified service personnel for repairs.
- Ensure proper grounding of the appliance.
- The fan is designed for indoor use only, specifically for bathrooms.
3. Package Contents
Verify that all components are present and undamaged before proceeding with installation.
- 1 x CATA X-Mart 12 Matic Inox Exhaust Fan Body
- 1 x Instruction Manual (this document)
Note: Additional mounting hardware (screws, wall plugs, ducting) may be required and are typically not included.
4. Product Specifications
| Feature | Specification |
|---|---|
| Brand | CATA |
| Model Number | 01055000 |
| Electric Fan Design | Exhaust Fan |
| Colour | INOX |
| Power Source | Electric |
| Room Type | Bathroom |
| Special Feature | Automatic Shutter System |
| Noise Level | 40 Decibels |
| Wattage | 20 Watts |
| Finish Type | Stainless Steel |
| Item Weight | 0.88 Kilograms |
| Item Dimensions (LxWxH) | 17 x 13.9 x 17 Centimeters |
| Suction Capacity | 190 m³/h |
| Diameter | 120 mm |
Figure 4.1: Performance curve for the X-Mart Matic 12, illustrating the relationship between static pressure and airflow volume.
5. Installation and Setup
The CATA X-Mart 12 Matic Inox fan is designed for fully recessed installation in walls or ceilings. It features an easy screw-less installation system.
5.1 Pre-Installation Checks
- Ensure the installation location is suitable for an exhaust fan, considering ventilation requirements and proximity to moisture sources.
- Verify that the wall or ceiling opening matches the fan's dimensions. Refer to the dimension diagram below.
- Confirm that the electrical supply meets the fan's requirements (20 Watts, standard household voltage).
- Gather necessary tools: screwdriver, drill, measuring tape, wire strippers, safety gloves, safety glasses.
Figure 5.1: Dimensional drawing for X-Mart Matic series. For Model 12, refer to the row with B=170mm, C=101mm, and ØA=118mm.
5.2 Installation Steps
- Disconnect Power: Turn off the main power supply to the installation area at the circuit breaker.
- Prepare Opening: Create or verify an opening in the wall or ceiling that accommodates the fan's dimensions (approximately 118mm diameter for the duct, and 170x170mm for the main body recess).
- Mount Fan Body: Insert the fan body into the prepared opening. The screw-less installation system allows for easy securing. Ensure it is flush with the surface.
- Electrical Connection: Connect the electrical wiring to the fan's terminal block. Ensure correct polarity (Live, Neutral, Earth) and secure all connections. Refer to local electrical codes.
- Attach Ducting (if applicable): If connecting to an external duct, secure the ducting to the fan's outlet using appropriate clamps or tape.
- Install Front Cover: Attach the removable screw-less front cover to the fan body. Ensure it clicks securely into place.
- Restore Power: Once installation is complete and all connections are secure, restore power at the circuit breaker.
- Test Operation: Turn on the fan to ensure it operates correctly. Observe the automatic front opening and airflow.
Figure 5.2: CATA X-Mart 12 Matic Inox Exhaust Fan, front view.
6. Operating Instructions
The CATA X-Mart 12 Matic Inox Exhaust Fan is designed for straightforward operation.
- Power On/Off: The fan is typically connected to a light switch or a dedicated fan switch in the bathroom. Flipping the switch to the 'ON' position will activate the fan.
- Automatic Shutter: Upon activation, the fan's automatic front opening mechanism will engage, allowing air to flow. When the fan is turned off, the shutter will close to prevent backdraft and maintain insulation.
- Operation Indicator Light: A small indicator light on the front panel will illuminate when the fan is operating, providing a visual confirmation of its status.
- Airflow: The fan will draw stale, humid air from the room and expel it through the ducting system, improving air quality and reducing moisture.
7. Maintenance
Regular cleaning and maintenance will ensure optimal performance and longevity of your exhaust fan.
7.1 Cleaning the Fan
- Disconnect Power: Always turn off the power supply to the fan at the circuit breaker before cleaning.
- Remove Front Cover: The fan features a removable screw-less front for easy access. Gently unclip or detach the front cover.
- Clean Cover: Wash the front cover with mild soap and water. Rinse thoroughly and dry completely before reattaching.
- Clean Fan Blades and Interior: Use a soft cloth or a vacuum cleaner with a brush attachment to carefully remove dust and debris from the fan blades, motor housing, and interior surfaces. Do not use abrasive cleaners or allow water to enter the motor.
- Reattach Front Cover: Once all parts are clean and dry, securely reattach the front cover.
- Restore Power: Turn the power supply back on.
Recommended cleaning frequency: Every 3-6 months, or more often in dusty or high-humidity environments.
8. Troubleshooting
If you encounter issues with your CATA X-Mart 12 Matic Inox Exhaust Fan, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fan does not turn on. | No power supply; loose wiring; faulty switch. | Check circuit breaker. Ensure switch is ON. Verify wiring connections (consult an electrician if unsure). |
| Fan is noisy or vibrating. | Loose mounting; debris in fan blades; motor issue. | Ensure fan is securely mounted. Disconnect power and clean fan blades. If noise persists, contact service. |
| Poor airflow. | Blocked ducting; dirty fan blades; automatic shutter not opening fully. | Clean fan blades and interior. Check ducting for obstructions. Ensure shutter mechanism is free of debris. |
| Automatic shutter not opening/closing. | Obstruction; mechanism fault. | Disconnect power and carefully check for any physical obstructions around the shutter mechanism. Clean if necessary. |
If the problem persists after attempting these solutions, please contact qualified service personnel.
9. Warranty and Support
CATA products are manufactured to high-quality standards. For information regarding warranty coverage, terms, and conditions, please refer to the warranty card included with your purchase or visit the official CATA website.
For technical support, spare parts, or service inquiries, please contact your local CATA distributor or authorized service center. When contacting support, please have your model number (01055000) and purchase details readily available.