1. Introduction
The Greenlee HVA-2000 is a high voltage digital ammeter designed for precise AC current measurements. This device allows for quick and easy ampere measurements on conductors up to 500kV. Its large, bright, 4-digit LED display ensures clear readability of current values, even from a distance when used with telescoping hotsticks. The HVA-2000 is engineered for ease of use and portability, making it suitable for live line operations.
Key features include 1% accuracy and the ability to store the last four readings, facilitating real-time monitoring or post-measurement analysis.

Figure 1: Greenlee HVA-2000 High Voltage Digital Ammeter and its protective carrying case. The ammeter features a red body with a digital display and an on/off button, designed for use with a hotstick.
2. Safety Information
Always adhere to local safety regulations and company policies when working with high voltage equipment. This device is intended for use by qualified personnel only.
- Use with Hotstick: The HVA-2000 requires a hotstick for safe operation. The hotstick is sold separately and is essential for maintaining a safe distance from high voltage conductors.
- Personal Protective Equipment (PPE): Always wear appropriate PPE, including insulated gloves, safety glasses, and flame-resistant clothing, when performing measurements on live circuits.
- Environmental Conditions: Do not use the ammeter in wet conditions or in environments where explosive gases or dust may be present.
- Inspection: Before each use, inspect the HVA-2000 and the hotstick for any signs of damage. Do not use if damaged.
3. Setup
3.1 Unpacking and Inspection
Carefully remove the HVA-2000 and its accessories from the nylon carrying case. Verify that all components are present and undamaged. The standard package includes the HVA-2000 unit and a nylon carrying case. A 9V battery is required for operation and is not included with the unit.
3.2 Battery Installation
- Locate the battery compartment on the HVA-2000 unit.
- Open the battery compartment cover.
- Insert one 9V battery, ensuring correct polarity (+/-).
- Close the battery compartment cover securely.
3.3 Attaching to a Hotstick
The HVA-2000 is designed to be attached to a standard telescoping hotstick (sold separately). Ensure the hotstick is clean, dry, and rated for the voltage level of the conductors being measured.
- Align the mounting mechanism of the HVA-2000 with the end of the hotstick.
- Securely fasten the ammeter to the hotstick according to the hotstick manufacturer's instructions. Ensure there is no wobble or looseness.
4. Operating Instructions
4.1 Powering On/Off
- To power on the HVA-2000, press the "ON" button located on the unit. The 4-digit LED display will illuminate.
- To power off, press the "OFF" button. The unit may also feature an auto-off function to conserve battery life.
4.2 Taking Measurements
The HVA-2000 is designed to measure AC current on conductors up to 500kV and up to 2000 amps, within a frequency range of 25 to 500 Hz.
- Ensure the HVA-2000 is securely attached to a hotstick.
- Extend the hotstick to safely reach the conductor.
- Carefully position the ammeter's jaws around the conductor. Ensure the conductor is fully enclosed within the jaws for accurate measurement.
- Read the current value displayed on the large LED screen. The display is designed for visibility from a distance.
- Once the measurement is complete, carefully remove the ammeter from the conductor using the hotstick.
4.3 Stored Readings Function
The HVA-2000 can store the last 4 readings. This feature allows for quick recall of recent measurements without needing to re-measure.
- Refer to the specific button or sequence on the device (if available, not detailed in provided data) to cycle through the stored readings.
- This function is particularly useful for comparing consecutive measurements or reviewing data after live line operations.
5. Maintenance
5.1 Cleaning
Keep the HVA-2000 clean and free from dust, dirt, and moisture. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
5.2 Storage
When not in use, store the HVA-2000 in its provided nylon carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Remove the 9V battery if the unit will not be used for an extended period to prevent battery leakage.
5.3 Battery Replacement
Replace the 9V battery when the low battery indicator appears on the display or if the unit fails to power on. Follow the battery installation steps outlined in Section 3.2.
6. Troubleshooting
This section provides solutions to common issues you might encounter with the HVA-2000.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not power on. | Dead or improperly installed battery. | Check battery polarity. Replace with a fresh 9V battery. |
| Inaccurate readings. | Conductor not fully enclosed; interference; unit malfunction. | Ensure jaws fully enclose conductor. Move away from strong electromagnetic fields. If problem persists, contact support. |
| Display is dim or flickering. | Low battery. | Replace the 9V battery. |
If you encounter issues not listed here or if the problem persists after attempting the suggested solutions, please contact Greenlee customer support for assistance.
7. Specifications
| Feature | Detail |
|---|---|
| Brand | Greenlee |
| Model Number | HVA-2000 |
| Measurement Type | Ammeter (AC Current) |
| Current Range | Up to 2000 Amps |
| Voltage Rating | Up to 500kV |
| Frequency Range | 25 to 500 Hz |
| Measurement Accuracy (50-60Hz) | 1–10A: 1% +/-2 counts 11–100A: 1% +/-3 counts 101–500A: 1% +/-6 counts 501–2000A: 1% +/-8 counts |
| Measurement Accuracy (25-49Hz and 61-500Hz) | 1–10A: 2% +/-3 counts 11–100A: 2% +/-4 counts 101–500A: 2% +/-6 counts 501–2000A: 2% +/-8 counts |
| Display | Large, bright 4-digit LED |
| Stored Readings | Last 4 readings |
| Power Source | One 9V battery (not included) |
| Item Dimensions (L x W x H) | 16.1 x 10.4 x 8.7 inches |
| Item Weight | 3.69 pounds |
| Included Components | HVA-2000 unit, nylon carrying case |
| Manufacturer | Greenlee Textron |
| UPC | 783310628309 |
8. Warranty and Support
8.1 Warranty Information
For detailed warranty information regarding your Greenlee HVA-2000 High Voltage Digital Ammeter, please refer to the warranty card included with your product or visit the official Greenlee website. Warranty terms and conditions may vary by region and product.
8.2 Customer Support
If you require technical assistance, have questions about product operation, or need to arrange for service, please contact Greenlee customer support. Contact information can typically be found on the Greenlee website or within the product packaging.
You can visit the official Greenlee website for more information: www.greenlee.com
9. Official Product Videos
No official product videos from the seller were found for the Greenlee HVA-2000 High Voltage Digital Ammeter in the provided data. For product demonstrations or instructional videos, please check the official Greenlee website or their authorized channels.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.