1. Introduction
The Elkron 80KT1N00111 Anti-Intrusion Alarm Kit is a comprehensive security solution designed to protect homes and workplaces. This kit integrates advanced components for reliable intrusion detection and notification. It includes a hybrid alarm control panel (MP500/8), a remote alphanumeric LCD keypad (KP500D/N), and a voice synthesizer module (SV500N). The system offers features such as remote access via web, video verification, and voice notifications, all certified to EN50131 Grade 3 standards.

Image 1.1: Elkron MP500/8 Control Panel. This image shows the white rectangular control panel with the ELKRON logo centrally placed on its cover.
2. Safety Information
Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in damage to the product, property, or personal injury.
- Power Disconnection: Always disconnect the main power supply before performing any installation, wiring, or maintenance procedures.
- Qualified Installation: Installation should be performed by qualified personnel in accordance with all local electrical codes and regulations.
- Wiring: Ensure all wiring connections are secure and correctly terminated to prevent short circuits or malfunctions.
- Environmental Conditions: Do not expose the components to extreme temperatures, humidity, or direct water contact.
- Battery Handling: Handle batteries according to manufacturer guidelines. Do not dispose of batteries in fire.
3. Package Contents
Verify that all components listed below are present in your package:
- MP500/8 Hybrid Alarm Control Panel: The central unit for system management.
- KP500D/N Remote Alphanumeric LCD Keypad: User interface for system control.
- SV500N Voice Synthesizer Module: Provides voice notifications and guidance.
- Headset: For use with the voice synthesizer module.
- Mounting Hardware: Screws and anchors for installation.
- User Manual: This document.
4. Setup
4.1. Control Panel (MP500/8) Installation
The MP500/8 control panel is the core of the system, featuring 8 expandable inputs up to 64, an integrated PSTN telephone communicator, and remote management capabilities. It supports remote video verification and video notification upon alarms. It is certified EN50131 Grade 3.
- Location Selection: Choose a secure, central, and discreet location for the control panel, away from direct sunlight, moisture, and extreme temperatures.
- Mounting: Securely mount the control panel to a wall using the provided mounting hardware. Ensure it is level and firmly attached.
- Power Connection: Connect the control panel to a dedicated power outlet. Ensure the backup battery is properly connected inside the panel.
- Wiring: Connect all zone wiring, siren, and other peripherals to the designated terminals on the control panel. Refer to the detailed wiring diagrams in the full technical manual for specific connections.
- Telephone Line (Optional): If using the integrated PSTN communicator, connect the telephone line to the appropriate terminal.
4.2. Keypad (KP500D/N) Installation
The KP500D/N keypad provides the primary user interface for system control. It features a 2-line, 16-character alphanumeric LCD display with adjustable backlight, contrast, and buzzer. It includes 3 alarm command keys and 2 alarm inputs. It is compatible with MP500/4, MP500/8, and MP500/16 control panels.

Image 4.1: Elkron KP500D/N Keypad. This image displays the white keypad with an LCD screen, numerical buttons, and navigation arrows, along with various status icons.
- Location Selection: Install the keypad at an easily accessible entry/exit point, typically near the main entrance.
- Mounting: Securely mount the keypad to a wall using the provided hardware.
- Connection: Connect the keypad to the control panel via the system bus. Ensure proper wiring polarity.
- Addressing: If multiple keypads are used, configure each keypad with a unique address according to the control panel's programming instructions.
4.3. Voice Synthesizer (SV500N) Installation
The SV500N voice synthesizer module connects to a dedicated connector on the control panel. It comes with a headset and factory-recorded messages for each input, sector, and system event. It supports a phonic BUS system for voice functions and environmental listening via the keypad (KP500DV model). It provides voice guidance for remote DTMF commands.
- Connection: Connect the SV500N module to the designated port on the MP500/8 control panel.
- Headset: Use the provided headset for initial configuration, message recording, and verification of voice prompts.
- Configuration: Follow the control panel's programming guide to enable and configure the voice synthesizer features, including custom messages if desired.
5. Operating Instructions
5.1. Arming and Disarming the System
To arm or disarm the system, use the KP500D/N keypad:
- To Arm: Enter your user code followed by the arm command (e.g., a specific key or sequence). The keypad display will confirm the system status.
- To Disarm: Enter your user code followed by the disarm command. The system will disarm, and the keypad will indicate the disarmed status.
- Partial Arming: The system supports partial arming, allowing specific zones to remain disarmed while others are armed (e.g., night mode). Refer to the control panel's programming manual for configuring and using partial arming modes.
5.2. Remote Access and Control
The Elkron 80KT1N00111 kit allows for remote management and monitoring:
- Web Interface: Access the system via a web browser on a PC for full control and monitoring.
- Mobile Application: Download the dedicated Elkron application for smartphones and tablets to manage the system on the go.
- Video Verification: Remotely view video feeds from connected cameras (if integrated) to verify alarms.
- Video Notification: Receive video clips or images upon alarm events directly to your connected devices.
5.3. Voice Features
The SV500N voice synthesizer enhances system interaction:
- Voice Notifications: Receive audible alerts and status updates for alarms and system events.
- Remote DTMF Commands: Control the system remotely via telephone using DTMF tones, guided by voice prompts from the SV500N.
- Environmental Listening: If using a KP500DV keypad, the phonic BUS system allows for environmental listening through the keypad.
6. Maintenance
Regular maintenance ensures the optimal performance and longevity of your alarm system:
- Battery Check: Periodically check the status of the control panel's backup battery and any batteries in wireless devices. Replace them as recommended by the manufacturer.
- Cleaning: Clean the keypad, sensors, and control panel housing with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
- System Test: Conduct a full system test at least once a month. This includes testing all sensors, sirens, and communication paths (PSTN, IP).
- Software Updates: Check the manufacturer's website for any available firmware or software updates for the control panel and related applications.
7. Troubleshooting
This section addresses common issues you might encounter with your Elkron alarm system.
- No Power to Control Panel:
- Check the main power connection and ensure the circuit breaker has not tripped.
- Verify that the backup battery is correctly connected and charged.
- Keypad Not Responding:
- Ensure the keypad is properly connected to the control panel's system bus.
- Check for any loose wiring or damage to the keypad cable.
- Verify the keypad's address setting is correct if multiple keypads are installed.
- False Alarms:
- Inspect sensors for obstructions, dust, or improper placement that might trigger false alarms.
- Adjust sensor sensitivity settings if applicable, following the control panel's programming guide.
- Ensure doors and windows are fully closed when arming the system.
- Remote Access Issues:
- Verify the internet connection for the control panel (if using IP communication).
- Check that the mobile application or web portal settings are correct and your login credentials are valid.
- Ensure your router or firewall is not blocking necessary ports for remote access.
- Voice Synthesizer Not Functioning:
- Confirm the SV500N module is securely connected to the control panel.
- Check the control panel's programming to ensure the voice features are enabled and configured correctly.
If you are unable to resolve an issue, please contact technical support or a qualified installer.
8. Specifications
| Feature | Description |
|---|---|
| Model Number | 80KT1N00111 |
| Brand | ELKRON |
| Control Panel | MP500/8 (8 inputs, expandable to 64, integrated PSTN communicator, remote WEB/tablet/smartphone/PC access, video verification, EN50131 Grade 3 certified) |
| Keypad | KP500D/N (Alphanumeric LCD, 2 lines x 16 characters, adjustable backlight/contrast/buzzer, 3 alarm keys, 2 alarm inputs) |
| Voice Synthesizer | SV500N (Pre-recorded messages, phonic BUS, environmental listening, voice guidance for DTMF) |
| Power Source | Battery and electric cable |
| Connectivity Technology | Wireless (for compatible devices) |
| Control Method | Application |
| Alert Type | Audio and motion |
| Recommended Use | Protection of homes and workplaces against intruders, unauthorized access monitoring. |
| Package Dimensions | 38.8 x 29.6 x 16.8 cm |
| Package Weight | 2.14 kg |
9. Warranty and Support
For detailed warranty information, please refer to the warranty card included with your product or visit the official ELKRON website. Keep your purchase receipt as proof of purchase for any warranty claims.
For technical support, troubleshooting assistance, or service inquiries, please contact your authorized ELKRON dealer or the ELKRON customer support team through their official channels.
- Manufacturer: ELKRON
- Website: www.elkron.it (Please verify the correct regional website)