ELKRON 80KT1N00111

Elkron 80KT1N00111 Anti-Intrusion Alarm Kit User Manual

Model: 80KT1N00111

1. Introduction

The Elkron 80KT1N00111 Anti-Intrusion Alarm Kit is a comprehensive security solution designed to protect homes and workplaces. This kit integrates advanced components for reliable intrusion detection and notification. It includes a hybrid alarm control panel (MP500/8), a remote alphanumeric LCD keypad (KP500D/N), and a voice synthesizer module (SV500N). The system offers features such as remote access via web, video verification, and voice notifications, all certified to EN50131 Grade 3 standards.

Elkron MP500/8 Control Panel with cover

Image 1.1: Elkron MP500/8 Control Panel. This image shows the white rectangular control panel with the ELKRON logo centrally placed on its cover.

2. Safety Information

Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in damage to the product, property, or personal injury.

  • Power Disconnection: Always disconnect the main power supply before performing any installation, wiring, or maintenance procedures.
  • Qualified Installation: Installation should be performed by qualified personnel in accordance with all local electrical codes and regulations.
  • Wiring: Ensure all wiring connections are secure and correctly terminated to prevent short circuits or malfunctions.
  • Environmental Conditions: Do not expose the components to extreme temperatures, humidity, or direct water contact.
  • Battery Handling: Handle batteries according to manufacturer guidelines. Do not dispose of batteries in fire.

3. Package Contents

Verify that all components listed below are present in your package:

  • MP500/8 Hybrid Alarm Control Panel: The central unit for system management.
  • KP500D/N Remote Alphanumeric LCD Keypad: User interface for system control.
  • SV500N Voice Synthesizer Module: Provides voice notifications and guidance.
  • Headset: For use with the voice synthesizer module.
  • Mounting Hardware: Screws and anchors for installation.
  • User Manual: This document.

4. Setup

4.1. Control Panel (MP500/8) Installation

The MP500/8 control panel is the core of the system, featuring 8 expandable inputs up to 64, an integrated PSTN telephone communicator, and remote management capabilities. It supports remote video verification and video notification upon alarms. It is certified EN50131 Grade 3.

  1. Location Selection: Choose a secure, central, and discreet location for the control panel, away from direct sunlight, moisture, and extreme temperatures.
  2. Mounting: Securely mount the control panel to a wall using the provided mounting hardware. Ensure it is level and firmly attached.
  3. Power Connection: Connect the control panel to a dedicated power outlet. Ensure the backup battery is properly connected inside the panel.
  4. Wiring: Connect all zone wiring, siren, and other peripherals to the designated terminals on the control panel. Refer to the detailed wiring diagrams in the full technical manual for specific connections.
  5. Telephone Line (Optional): If using the integrated PSTN communicator, connect the telephone line to the appropriate terminal.

4.2. Keypad (KP500D/N) Installation

The KP500D/N keypad provides the primary user interface for system control. It features a 2-line, 16-character alphanumeric LCD display with adjustable backlight, contrast, and buzzer. It includes 3 alarm command keys and 2 alarm inputs. It is compatible with MP500/4, MP500/8, and MP500/16 control panels.

Elkron KP500D/N Keypad

Image 4.1: Elkron KP500D/N Keypad. This image displays the white keypad with an LCD screen, numerical buttons, and navigation arrows, along with various status icons.

  1. Location Selection: Install the keypad at an easily accessible entry/exit point, typically near the main entrance.
  2. Mounting: Securely mount the keypad to a wall using the provided hardware.
  3. Connection: Connect the keypad to the control panel via the system bus. Ensure proper wiring polarity.
  4. Addressing: If multiple keypads are used, configure each keypad with a unique address according to the control panel's programming instructions.

4.3. Voice Synthesizer (SV500N) Installation

The SV500N voice synthesizer module connects to a dedicated connector on the control panel. It comes with a headset and factory-recorded messages for each input, sector, and system event. It supports a phonic BUS system for voice functions and environmental listening via the keypad (KP500DV model). It provides voice guidance for remote DTMF commands.

  1. Connection: Connect the SV500N module to the designated port on the MP500/8 control panel.
  2. Headset: Use the provided headset for initial configuration, message recording, and verification of voice prompts.
  3. Configuration: Follow the control panel's programming guide to enable and configure the voice synthesizer features, including custom messages if desired.

5. Operating Instructions

5.1. Arming and Disarming the System

To arm or disarm the system, use the KP500D/N keypad:

  • To Arm: Enter your user code followed by the arm command (e.g., a specific key or sequence). The keypad display will confirm the system status.
  • To Disarm: Enter your user code followed by the disarm command. The system will disarm, and the keypad will indicate the disarmed status.
  • Partial Arming: The system supports partial arming, allowing specific zones to remain disarmed while others are armed (e.g., night mode). Refer to the control panel's programming manual for configuring and using partial arming modes.

5.2. Remote Access and Control

The Elkron 80KT1N00111 kit allows for remote management and monitoring:

  • Web Interface: Access the system via a web browser on a PC for full control and monitoring.
  • Mobile Application: Download the dedicated Elkron application for smartphones and tablets to manage the system on the go.
  • Video Verification: Remotely view video feeds from connected cameras (if integrated) to verify alarms.
  • Video Notification: Receive video clips or images upon alarm events directly to your connected devices.

5.3. Voice Features

The SV500N voice synthesizer enhances system interaction:

  • Voice Notifications: Receive audible alerts and status updates for alarms and system events.
  • Remote DTMF Commands: Control the system remotely via telephone using DTMF tones, guided by voice prompts from the SV500N.
  • Environmental Listening: If using a KP500DV keypad, the phonic BUS system allows for environmental listening through the keypad.

6. Maintenance

Regular maintenance ensures the optimal performance and longevity of your alarm system:

  • Battery Check: Periodically check the status of the control panel's backup battery and any batteries in wireless devices. Replace them as recommended by the manufacturer.
  • Cleaning: Clean the keypad, sensors, and control panel housing with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
  • System Test: Conduct a full system test at least once a month. This includes testing all sensors, sirens, and communication paths (PSTN, IP).
  • Software Updates: Check the manufacturer's website for any available firmware or software updates for the control panel and related applications.

7. Troubleshooting

This section addresses common issues you might encounter with your Elkron alarm system.

  • No Power to Control Panel:
    • Check the main power connection and ensure the circuit breaker has not tripped.
    • Verify that the backup battery is correctly connected and charged.
  • Keypad Not Responding:
    • Ensure the keypad is properly connected to the control panel's system bus.
    • Check for any loose wiring or damage to the keypad cable.
    • Verify the keypad's address setting is correct if multiple keypads are installed.
  • False Alarms:
    • Inspect sensors for obstructions, dust, or improper placement that might trigger false alarms.
    • Adjust sensor sensitivity settings if applicable, following the control panel's programming guide.
    • Ensure doors and windows are fully closed when arming the system.
  • Remote Access Issues:
    • Verify the internet connection for the control panel (if using IP communication).
    • Check that the mobile application or web portal settings are correct and your login credentials are valid.
    • Ensure your router or firewall is not blocking necessary ports for remote access.
  • Voice Synthesizer Not Functioning:
    • Confirm the SV500N module is securely connected to the control panel.
    • Check the control panel's programming to ensure the voice features are enabled and configured correctly.

If you are unable to resolve an issue, please contact technical support or a qualified installer.

8. Specifications

FeatureDescription
Model Number80KT1N00111
BrandELKRON
Control PanelMP500/8 (8 inputs, expandable to 64, integrated PSTN communicator, remote WEB/tablet/smartphone/PC access, video verification, EN50131 Grade 3 certified)
KeypadKP500D/N (Alphanumeric LCD, 2 lines x 16 characters, adjustable backlight/contrast/buzzer, 3 alarm keys, 2 alarm inputs)
Voice SynthesizerSV500N (Pre-recorded messages, phonic BUS, environmental listening, voice guidance for DTMF)
Power SourceBattery and electric cable
Connectivity TechnologyWireless (for compatible devices)
Control MethodApplication
Alert TypeAudio and motion
Recommended UseProtection of homes and workplaces against intruders, unauthorized access monitoring.
Package Dimensions38.8 x 29.6 x 16.8 cm
Package Weight2.14 kg

9. Warranty and Support

For detailed warranty information, please refer to the warranty card included with your product or visit the official ELKRON website. Keep your purchase receipt as proof of purchase for any warranty claims.

For technical support, troubleshooting assistance, or service inquiries, please contact your authorized ELKRON dealer or the ELKRON customer support team through their official channels.

  • Manufacturer: ELKRON
  • Website: www.elkron.it (Please verify the correct regional website)

Related Documents - 80KT1N00111

Preview Elkron MP500/8 Installationshandbuch
Installationshandbuch für die Elkron MP500/8 Alarmzentrale. Enthält detaillierte Anweisungen zur Systemarchitektur, Installation, Verkabelung, Inbetriebnahme und technischen Spezifikationen für professionelle Sicherheitssysteme.
Preview Elkron EP3008 8-Point Expansion Module - Technical Specifications
Detailed technical specifications and installation guide for the Elkron EP3008, an 8-point programmable expansion module for alarm and security systems. Covers connections, assembly, and features.
Preview Elkron C420 Programming Manual
This programming manual provides detailed instructions and configurations for the Elkron C420 conventional fire alarm control panel, covering zone programming, output settings, and system service functions.
Preview ELKRON IRA15P Digital Infrared Detector with Pet Immunity - IS3120-AA
The ELKRON IRA15P (IS3120-AA) is a digital infrared motion detector designed for security systems, featuring adjustable pet immunity up to 35kg. This document provides technical specifications, installation guidelines, and configuration details for the device.
Preview Elkron MC500 MC100 DECT CKT Resistor Connection Guide
Instructions for connecting an 18KΩ ¼W resistor to the DECT CKT terminal block of the Elkron MC500 and MC100 wireless modules, specifying the '+' and '-' positions.
Preview Manuale di Installazione e Specifiche Tecniche Tastiera ELKRON KP710D/KP710DP
Scopri le caratteristiche, l'installazione e le specifiche tecniche della tastiera ELKRON KP710D e KP710DP, un'interfaccia avanzata per sistemi di sicurezza MEDEA con lettore di prossimità opzionale.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.