1. Introduction

This manual provides essential information for the safe and efficient operation of your Comfort Glow KWN211 12000 BTU Natural Gas Vent-Free Wall Heater. Please read all instructions carefully before installation and use. Retain this manual for future reference.

2. Important Safety Information

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, or the gas supplier.

  • This appliance is for indoor use only.
  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Due to the built-in oxygen safety sensor, vent-free products may not work properly at elevations above 4500 ft.
  • The state of California prohibits the use of this product. Always check your state and local codes prior to purchase and installation.
  • Ensure adequate ventilation when operating the heater.
  • Keep children and pets away from the heater when in operation.
  • Do not place clothing or other flammable materials on or near the heater.
  • This heater is equipped with an Oxygen Depletion Sensor (ODS) safety pilot system, which will shut off the heater if oxygen levels become too low.

Proposition 65 Warning: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

3. Product Overview

The Comfort Glow KWN211 is a vent-free infrared natural gas wall heater designed to provide efficient heating without requiring electricity or external venting. It features two ceramic plaques for radiant heat and manual controls.

Comfort Glow KWN211 Front View

Figure 3.1: Front view of the Comfort Glow KWN211 heater, showcasing the protective grill and ceramic plaques.

Comfort Glow KWN211 Features Diagram

Figure 3.2: Diagram highlighting key features including electronic ignition, adjustable heat control, two ceramic plaque heating elements, and the included wall-mounting kit. Also notes vent-free operation and optional blower/floor mount accessories.

Comfort Glow KWN211 Side View

Figure 3.3: Side view of the Comfort Glow KWN211 heater, showing its compact design.

Comfort Glow KWN211 Rear View

Figure 3.4: Rear view of the Comfort Glow KWN211 heater, showing the mounting points and gas inlet.

Comfort Glow KWN211 Dimensions

Figure 3.5: Dimensions of the Comfort Glow KWN211 heater: 20" H x 17.3" W x 9.1" D.

Key Features:

  • Vent-Free Infrared Burner: Provides efficient heat without the need for a chimney or vent.
  • No Electricity Required: Operates independently of electrical power, ideal for emergencies.
  • Manual Control: Features adjustable heat settings for personalized comfort.
  • Built-in Oxygen Depletion Sensor (ODS): Enhances safety by monitoring oxygen levels.
  • Heating Area: Heats approximately 500 sq. ft.
  • Fuel Type: Natural Gas.

4. Setup & Installation

The Comfort Glow KWN211 heater can be wall-mounted using the included kit or placed on the floor with an optional floor stand (Model #20-5345, sold separately). Ensure all local codes and regulations are followed during installation.

4.1. Pre-Installation Checks

  • Verify that the heater is suitable for natural gas.
  • Confirm that your location is not above 4500 ft elevation, as the ODS system may malfunction.
  • Ensure installation complies with all local building and safety codes, including those regarding vent-free appliances.

4.2. Wall Mounting

A wall bracket and mounting hardware are included. Select a suitable wall location away from combustible materials and high traffic areas. Follow the detailed instructions provided in the separate installation guide for secure wall mounting.

Comfort Glow KWN211 Wall Mounting Steps

Figure 4.1: Illustration of the wall mounting process, showing the bracket attachment and heater placement.

Comfort Glow KWN211 Wall Mounted

Figure 4.2: The Comfort Glow KWN211 heater securely mounted on a wall.

4.3. Floor Standing (Optional)

If you prefer a portable setup, an optional floor stand (Model #20-5345) can be purchased separately. Attach the stand according to its instructions. An optional blower (Model #20-6127) is also available, requiring a 120V grounded outlet.

Optional Blower and Floor Mounting Kit for Comfort Glow KWN211

Figure 4.3: Image showing the optional blower and floor mounting kit, sold separately.

4.4. Gas Connection

Connect the heater to a natural gas supply line. This connection must be performed by a qualified professional in accordance with all local codes. Ensure all connections are leak-tested before operation.

Comfort Glow KWN211 Gas Connection Diagram

Figure 4.4: Diagram illustrating the gas connection point on the heater's rear.

5. Operating Instructions

The Comfort Glow KWN211 features simple manual controls for ignition and heat adjustment.

5.1. Controls Overview

Comfort Glow KWN211 Control Panel

Figure 5.1: Close-up of the control panel, showing the heat setting knob and piezo ignition button.

Comfort Glow KWN211 Control Knob

Figure 5.2: Detailed view of the control knob, indicating settings from OFF to PILOT and heat levels 1-5.

5.2. Ignition Procedure (Piezo Ignition)

  1. Ensure the gas supply is open.
  2. Turn the control knob to the "PILOT" position.
  3. Press and hold the control knob in while repeatedly pressing the piezo igniter button until the pilot flame ignites.
  4. Continue to hold the control knob in for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up. Release the knob slowly. If the pilot goes out, repeat the process.

5.3. Adjusting Heat Settings

  1. Once the pilot is lit, turn the control knob counter-clockwise to the desired heat setting (1-5).
  2. The heater will begin to radiate heat from the ceramic plaques.
  3. To decrease heat, turn the knob clockwise to a lower setting.

5.4. Shutting Down the Heater

  1. To turn off the main burner, turn the control knob clockwise to the "PILOT" position. The pilot light will remain lit.
  2. To completely shut down the heater, turn the control knob to the "OFF" position. This will extinguish both the main burner and the pilot light.
  3. For extended periods of non-use, it is recommended to close the main gas supply valve to the heater.

6. Maintenance

Regular maintenance ensures the safe and efficient operation of your heater. Always turn off the heater and disconnect the gas supply before performing any maintenance.

  • Cleaning: Periodically clean the exterior of the heater with a soft, damp cloth. Do not use abrasive cleaners. Keep the air intake and exhaust vents clear of dust and debris.
  • Pilot and Burner Inspection: Annually inspect the pilot and burner for any obstructions or signs of damage. A qualified service technician should perform this inspection.
  • Gas Connections: Check gas connections for leaks periodically using a soap solution. Never use an open flame to check for leaks.

7. Troubleshooting

If your heater is not operating correctly, consult the following common issues before contacting support.

ProblemPossible CauseSolution
Heater will not ignite.No gas supply; Pilot light not lit; ODS system activated.Ensure gas supply is open. Follow ignition procedure carefully. Check for proper ventilation.
Pilot light goes out after releasing knob.Thermocouple not heated sufficiently; Faulty thermocouple.Hold knob in longer (60 seconds). If problem persists, contact service.
Heater produces insufficient heat.Incorrect heat setting; Heater too small for space; Gas pressure issue.Adjust to a higher setting. Verify heater BTU matches room size. Consult gas supplier.
Unusual odors.Initial burn-off; Gas leak.A slight odor is normal during first use. If strong gas odor, immediately shut off gas and ventilate area, then contact gas company.

8. Specifications

FeatureDetail
BrandComfort Glow
Model NumberKWN211
Burner TypeRadiant (2 Plaque Infrared)
BTU Output12,000 BTU
Fuel TypeNatural Gas
Heating CoverageUp to 500 sq. ft.
Special Features99.9% Fuel Efficient, Manual Control, No Electricity Required, Safe Watch Pilot / ODS System, Vent-Free
Ignition TypePiezo Ignition
Product Dimensions9.1"D x 17.3"W x 20"H
Item Weight16.4 pounds
Mounting TypeWall Mount (hardware included) / Floor Stand (optional)
ColorGray
UPC013204402112

9. Warranty Information

This Comfort Glow KWN211 heater comes with a 2-year manufacturer's warranty. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty card included with your product or contact customer support.

10. Customer Support

For technical assistance, parts, or service inquiries, please visit the manufacturer's technical support website:

World Marketing of America Technical Support

When contacting support, please have your model number (KWN211) and serial number ready.

© 2023 Comfort Glow. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.