1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your DANFOSS Compressor, Model SC15CLX.2. This compressor is designed for use with R-404A refrigerant and operates on a 115V, 1-Phase power supply, delivering 3/4 HP. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the unit.

Figure 1: DANFOSS SC15CLX.2 Compressor. The image displays the main compressor unit, which is black and oval-shaped, along with its associated electrical components, including a capacitor, a relay/starter box, and mounting hardware such as rubber grommets, bolts, and washers. These components are typically used for installation and electrical connection of the compressor.
2. Setup and Installation
Proper installation is crucial for the performance and safety of the compressor. It is recommended that installation be performed by a qualified technician.
2.1 Safety Precautions
- Ensure power supply is disconnected before any installation or maintenance work.
- Handle refrigerants with care and in accordance with local regulations.
- Wear appropriate personal protective equipment (PPE), including gloves and eye protection.
- Verify that the electrical supply matches the compressor's voltage requirements (115V, 1-Phase).
2.2 Mounting
Mount the compressor on a stable, level surface using the provided mounting hardware. Ensure adequate ventilation around the unit to prevent overheating. The compressor should be installed in a location that allows for easy access for maintenance.
2.3 Electrical Connections
Connect the compressor to the electrical system according to the wiring diagram provided with the unit (not included in this manual). Ensure all connections are secure and properly insulated. The compressor requires a 115V, 1-Phase power source.
2.4 Refrigerant System Connection
Connect the compressor to the refrigeration system using appropriate fittings and procedures. Ensure the system is clean, dry, and free of contaminants. Evacuate the system thoroughly before charging with R-404A refrigerant. Verify all connections are leak-free.
3. Operating Instructions
Once installed and connected, the compressor operates as part of a larger refrigeration system. Its operation is typically controlled by the system's thermostat and pressure switches.
3.1 Initial Start-up
- After completing all installation steps and leak checks, slowly introduce the R-404A refrigerant into the system.
- Monitor system pressures and temperatures during the initial charge.
- Once the system is charged to the manufacturer's specifications, apply power to the unit.
- Observe the compressor's operation, listening for unusual noises and checking for proper cycling.
3.2 Normal Operation
The compressor will cycle on and off as required to maintain the desired temperature set by the system's controls. Ensure the ambient temperature around the compressor does not exceed its operational limits. The typical noise level during operation is approximately 69 dB.
4. Maintenance
Regular maintenance helps ensure the longevity and efficiency of your DANFOSS compressor.
4.1 Routine Checks
- Cleanliness: Keep the compressor and surrounding area clean and free of dust and debris to ensure proper heat dissipation.
- Vibration: Periodically check for excessive vibration, which may indicate loose mounting or internal issues.
- Connections: Inspect electrical and refrigerant connections for signs of wear, corrosion, or leaks.
- Noise Level: Note any significant changes in operating noise, which could signal a problem.
4.2 Professional Servicing
It is recommended to have the refrigeration system, including the compressor, inspected by a qualified HVAC/R technician annually. They can check refrigerant levels, system pressures, and overall performance.
5. Troubleshooting
This section provides guidance on common issues. For complex problems, consult a qualified technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Compressor not starting | No power, faulty thermostat, faulty start relay/capacitor, low refrigerant charge. | Check power supply, inspect thermostat, test/replace relay/capacitor, check refrigerant levels. |
| Compressor runs continuously | Low refrigerant, dirty condenser coils, oversized load, faulty thermostat. | Check refrigerant, clean coils, verify system load, inspect thermostat. |
| Unusual noise from compressor | Loose mounting, internal mechanical issue, refrigerant slugging. | Check mounting bolts, consult technician for internal issues, ensure proper refrigerant charge. |
| Poor cooling performance | Low refrigerant, restricted airflow, faulty expansion valve, compressor inefficiency. | Check refrigerant, clear obstructions, inspect expansion valve, consult technician. |
6. Specifications
| Attribute | Value |
|---|---|
| Model Number | SC15CLX.2 |
| Brand | Danfoss |
| Refrigerant Type | R-404A / R-507 |
| Voltage | 115 Volts |
| Phase | 1-Phase |
| Horsepower | 3/4 HP |
| Product Dimensions | 12.1 x 7.9 x 12.2 inches |
| Item Weight | 0.16 ounces |
| Noise Level | 69 dB |
| Recommended Use | Automotive Air Conditioning |
| Power Source | Corded Electric |
| Manufacturer | CAI - DANFOSS |
7. Warranty and Support
For specific warranty information, please refer to the documentation provided at the time of purchase or contact your authorized Danfoss dealer. Danfoss offers various protection plans for extended coverage. For technical support or service inquiries, please contact Danfoss customer service or an authorized service center.
Note: The product is listed with available protection plans, including 3-Year and 4-Year options, and a monthly Complete Protect plan. These plans are separate from the standard manufacturer's warranty and provide extended coverage.