Glentronics E7055-NS

Glentronics E7055-NS Pro Series Sewage Pump Instruction Manual

Model: E7055-NS

1. Introduction and Overview

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Glentronics E7055-NS Pro Series Sewage Pump. Please read this manual thoroughly before attempting to install or operate the pump. Retain this manual for future reference.

The Glentronics E7055-NS is a 1/2 HP all cast iron sewage pump designed for reliable performance in demanding applications. It features a high-efficiency Permanent Split Capacitor (PSC) motor for reduced energy consumption and quiet operation, supported by sealed upper and lower ball bearings. The cast iron, vortex impeller is capable of handling 2-inch solids. This pump is water-cooled, thermally protected, and rated for continuous duty, ensuring durability and consistent performance.

Glentronics E7055-NS Pro Series Sewage Pump

Figure 1.1: Glentronics E7055-NS Pro Series Sewage Pump. This image displays the blue cast iron unit with a handle on top and a discharge port on the side, designed for sewage applications.

2. Safety Information

WARNING: Failure to follow these safety instructions could result in electric shock, fire, serious injury, or death.

  • Always disconnect power to the pump before performing any service or maintenance.
  • Ensure all electrical connections are made by a qualified electrician and comply with local codes.
  • Do not operate the pump with a damaged cord or plug.
  • Do not use this pump for flammable liquids or in hazardous locations.
  • Wear appropriate personal protective equipment (PPE) during installation and maintenance.
  • Keep hands and feet clear of the impeller and discharge opening when the pump is connected to power.
  • Ensure the pump is properly grounded to prevent electrical shock.

3. Product Features

The Glentronics E7055-NS Pro Series Sewage Pump offers the following key features:

  • High Capacity: Delivers 5,340 GPH (89 GPM) at a 10 ft. lift.
  • Durable Construction: Made from robust cast iron for extended lifespan.
  • Continuous Duty Rated: Designed for sustained operation without overheating.
  • Energy Efficient Motor: Equipped with a Permanent Split Capacitor (PSC) motor for lower power consumption.
  • Solids Handling: Capable of handling 2-inch solids with a 2-inch discharge.
  • Quiet Operation: Features upper and lower sealed ball bearings for reduced noise.
  • Thermal Protection: Integrated protection against motor overheating.

4. Specifications

Specification Detail
Model Number E7055-NS
Brand Glentronics
Horsepower 1/2 HP
Material Cast Iron, Stainless Steel
Color Stainless Steel
Item Weight 37 Pounds
Product Dimensions 18.75 x 12 x 7.5 inches
Discharge Size 2 inches
Solids Handling 2 inches
Flow Rate (at 10 ft. lift) 5,340 GPH (89 GPM)
Motor Type Permanent Split Capacitor (PSC)
UPC 635409460966, 727904483288, 076335159096
ASIN B00PM8MCLU

5. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your sewage pump. Consult a qualified plumber or electrician if you are unsure about any steps.

5.1 Pre-Installation Checklist

  • Verify that the power supply matches the pump's voltage requirements.
  • Ensure the sump basin is clean and free of debris.
  • Confirm that the discharge piping is correctly sized (2 inches minimum) and free of obstructions.
  • Have all necessary tools and materials ready, including PVC cement, pipe wrenches, and electrical supplies.

5.2 Installation Steps

  1. Positioning the Pump: Place the pump on a solid, level surface at the bottom of the sump basin. Ensure it is not resting directly on soft sediment.
  2. Discharge Piping: Connect the pump's discharge port to the existing discharge piping using appropriate fittings and sealant. A check valve should be installed above the pump to prevent backflow.
  3. Electrical Connection: Connect the pump to a dedicated, grounded electrical circuit. Use a Ground Fault Circuit Interrupter (GFCI) outlet for added safety. Ensure the power cord is not pinched or damaged.
  4. Float Switch (if applicable): If your model includes a float switch, ensure it is positioned correctly to activate and deactivate the pump at desired water levels without obstruction.
  5. Testing: After installation, slowly fill the sump basin with water to test the pump's operation. Observe for proper activation, discharge, and deactivation. Check for any leaks.

6. Operating Instructions

The Glentronics E7055-NS pump is designed for automatic operation when connected to a float switch system. Manual operation is not typically recommended for sewage applications.

6.1 Automatic Operation

  • Once properly installed and connected to power, the pump will activate automatically when the water level in the sump basin rises to the float switch's "ON" position.
  • The pump will continue to operate, discharging wastewater, until the water level drops to the float switch's "OFF" position.
  • Ensure the float switch has a clear range of motion and is not obstructed by the basin walls or other components.

6.2 Initial Start-up

During the first few cycles, monitor the pump to ensure it is functioning correctly. Listen for unusual noises and check for proper water flow and complete drainage of the basin.

7. Maintenance

Regular maintenance helps ensure the longevity and reliable performance of your sewage pump.

7.1 Routine Checks (Monthly/Quarterly)

  • Power Disconnection: Always disconnect power before any inspection or maintenance.
  • Sump Basin Inspection: Check the sump basin for excessive debris, sludge buildup, or foreign objects that could impede pump operation or float switch movement.
  • Float Switch Check: Manually lift and lower the float switch to ensure it moves freely and activates/deactivates the pump correctly.
  • Discharge Piping: Inspect the discharge pipe and check valve for any signs of leaks or blockages.
  • Power Cord: Examine the power cord for any cuts, abrasions, or damage. Replace if necessary.

7.2 Cleaning

If significant sludge or debris accumulates, the pump may need to be removed from the basin for thorough cleaning. Use a stiff brush and water to clean the pump housing and impeller area. Ensure all debris is removed from the impeller vanes.

CAUTION: Do not use harsh chemicals or solvents that could damage pump components.

8. Troubleshooting

This section provides solutions to common issues you might encounter with your sewage pump.

Problem Possible Cause Solution
Pump does not start No power; Tripped circuit breaker/GFCI; Faulty float switch; Motor overload. Check power supply; Reset breaker/GFCI; Inspect/replace float switch; Allow motor to cool and reset thermal protector.
Pump runs but no water discharges Clogged impeller or discharge pipe; Air lock; Check valve stuck closed. Disconnect power, clear obstructions; Prime pump if air locked; Inspect/replace check valve.
Pump runs continuously Stuck float switch; Leaking check valve; Continuous inflow. Inspect/free float switch; Replace check valve; Investigate source of continuous water inflow.
Pump cycles too frequently Float switch set too close; Leaking check valve; Small sump basin. Adjust float switch settings; Replace check valve; Consider a larger sump basin if feasible.
Excessive noise or vibration Debris in impeller; Worn bearings; Pump not sitting level. Disconnect power, clear impeller; Contact service for bearing replacement; Ensure pump is level.

If troubleshooting steps do not resolve the issue, contact Glentronics customer support or a qualified service technician.

9. Warranty and Support

Warranty information for the Glentronics E7055-NS Pro Series Sewage Pump is typically provided with the product at the time of purchase. Please refer to the documentation included in your product packaging for specific warranty terms and conditions.

For technical support, replacement parts, or warranty claims, please contact Glentronics customer service directly. Contact information can usually be found on the manufacturer's website or in the product packaging.

Manufacturer: Glentronics

Model: E7055-NS

Related Documents - E7055-NS

Preview Glentronics Pro Series S1033 Sump Pump: Installation, Safety, and Operation Manual
Comprehensive guide for the Glentronics Pro Series S1033 Sump Pump, covering safety instructions, installation, operation, troubleshooting, and warranty information.
Preview Glentronics Pro Series Sump Pumps S2033 & S2050: Installation, Safety, and Operation Manual
Comprehensive guide for Glentronics Pro Series Sump Pumps Models S2033 and S2050, covering essential safety warnings, installation instructions, product operation, maintenance, troubleshooting, and warranty information.
Preview Glentronics PS-WiFi2 Module: Quick Start & Installation Guide
This guide provides quick setup and installation instructions for the Glentronics PS-WiFi2 Module, enabling remote monitoring of sump pump systems via Wi-Fi. It covers initial setup, Wi-Fi connection, app registration, installation details, and warranty information.
Preview PHCC Pro Series 1730 Battery Backup Sump Pump System: Instruction Manual & Safety Warnings
Comprehensive instruction manual and safety warnings for the PHCC Pro Series 1730 Battery Backup Sump Pump System. Covers installation, operation, maintenance, troubleshooting, and warranty information.
Preview Glentronics, Inc. Limited Warranty
Details the limited warranty terms for Glentronics, Inc. products, including coverage, exclusions, and service procedures for pumps, switches, and control units, with a one-year warranty period for parts and labor when used with a Basement Watchdog sump pump system.
Preview Pro Series PS-C33 Combination Sump Pump System: Instruction Manual & Safety Warnings
Detailed instruction manual and safety warnings for the Pro Series PS-C33 Combination Primary and Backup Sump Pump System. Learn about installation, operation, maintenance, and troubleshooting for reliable basement flood protection.