LEDVANCE 22401

SYLVANIA OCTRON T8 Fluorescent Lamp User Manual

Model: 22401

1. Introduction

This manual provides comprehensive instructions for the SYLVANIA OCTRON T8 Fluorescent Lamp, Model 22401. It covers essential information regarding product overview, safety, installation, operation, maintenance, troubleshooting, and technical specifications. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Safety Information

Observe the following safety precautions to prevent injury or damage:

3. Product Overview

The SYLVANIA OCTRON T8 Fluorescent Lamp (Model 22401) is a 32-watt, G12 base lamp designed for general illumination. It provides 2450 lumens of light with a 3500K color temperature, offering a natural white light appearance. With a Color Rendering Index (CRI) of 90, it delivers excellent color accuracy, making it suitable for environments where color perception is critical. The lamp is energy-efficient and has an average rated life of up to 22,500 hours on instant start ballasts and up to 27,000 hours on programmed start ballasts.

SYLVANIA OCTRON T8 Fluorescent Lamp packaging, showing 'Natural White' and 'OCTRON ECOLOGIC' branding.

Figure 3.1: Packaging for the SYLVANIA OCTRON T8 Fluorescent Lamp, highlighting its 'Natural White' color and 'Ecologic' features.

Side view of SYLVANIA OCTRON T8 Fluorescent Lamp packaging, showing specifications like wattage and color temperature.

Figure 3.2: Side view of the lamp packaging, detailing technical specifications such as 32W and 3500K.

4. Setup and Installation

Follow these steps for safe and correct installation:

  1. Turn Off Power: Locate the circuit breaker or fuse box controlling the lighting fixture and turn off the power supply. Verify that the power is off before proceeding.
  2. Remove Old Lamp (if applicable): Carefully twist the old fluorescent lamp 90 degrees and gently pull it out of the lampholders.
  3. Inspect Fixture: Check the lampholders for any damage or wear. Ensure they are clean and free from debris.
  4. Insert New Lamp: Align the pins of the new SYLVANIA OCTRON T8 lamp with the slots in the lampholders. Gently push the lamp into the lampholders until the pins are fully seated, then rotate the lamp 90 degrees until it locks into place.
  5. Verify Secure Fit: Ensure the lamp is securely seated and properly aligned in the fixture.
  6. Restore Power: Turn the power supply back on at the circuit breaker or fuse box.
  7. Test Lamp: Turn on the light switch to confirm the lamp illuminates correctly.

Note: For optimal performance and warranty coverage, pair OCTRON T8 lamps with QUICKTRONIC electronic ballasts.

5. Operating Instructions

The SYLVANIA OCTRON T8 Fluorescent Lamp operates by simply turning on the power switch connected to the lighting fixture. The lamp is designed for rapid and instant start systems, providing immediate illumination.

6. Maintenance

Minimal maintenance is required for the SYLVANIA OCTRON T8 Fluorescent Lamp:

7. Troubleshooting

If your SYLVANIA OCTRON T8 lamp is not functioning as expected, consider the following:

ProblemPossible CauseSolution
Lamp does not light upNo power to fixture, incorrect installation, faulty lamp, faulty ballast.Check power supply. Re-seat lamp. Test with a known good lamp. Consult an electrician if ballast is suspected.
Lamp flickersLoose connection, incompatible ballast, lamp nearing end of life, cold temperatures.Ensure lamp is securely seated. Verify ballast compatibility. Replace lamp if old. Ensure operating environment is within recommended temperature range.
Reduced brightnessDust accumulation, lamp nearing end of life.Clean lamp surface. Replace lamp if old.
Ends of lamp glow but do not fully lightFaulty ballast, lamp nearing end of life.Consult an electrician for ballast inspection. Replace lamp.

If troubleshooting steps do not resolve the issue, contact customer support or a qualified electrician.

8. Specifications

FeatureSpecification
BrandLEDVANCE (SYLVANIA)
Model Number22401
Light TypeFluorescent
Bulb Shape SizeT8
Bulb BaseG12
Wattage32 Watts
Voltage120 Volts
Brightness2450 Lumens
Color Temperature3500 Kelvin (Natural White)
Color Rendering Index (CRI)90
Average LifeUp to 22,500 hours (Instant Start), up to 27,000 hours (Programmed Start)
Product Dimensions48 x 1.1 x 1.1 inches
MaterialGlass
Special FeatureEnergy Efficient
UPC046135224010

9. Warranty and Support

For warranty information and customer support, please refer to the official SYLVANIA website or contact LEDVANCE customer service.

Warranty Description: www.sylvania.com

For further assistance, please visit the LEDVANCE store or contact their support channels.

Related Documents - 22401

Preview LEDVANCE T4 Compact Fluorescent Programmed Rapid Start Ballast LTP2X26CFUNVDM
Technical specifications, application details, and ordering information for the LEDVANCE T4 Compact Fluorescent Programmed Rapid Start Ballast (Model LTP2X26CFUNVDM), designed for 120-277V high efficiency lighting in commercial and institutional applications.
Preview LED TUBE T8 UNIVERSAL: Installation and Operation Guide
Comprehensive guide for installing and operating the LED TUBE T8 UNIVERSAL, a replacement for T8 fluorescent lamps. Includes technical specifications, retrofit, and conversion instructions.
Preview LED Retrofit Downlight 6" Installation and Operation Manual - LEDVANCE
Comprehensive guide for installing and operating the LEDVANCE 6-inch LED Retrofit Downlight (Model LEDRT561000ST9SC3WH), including safety instructions, troubleshooting, and warranty information.
Preview LEDVANCE LED Microdisk 4" Installation and Operation Guide
This guide provides detailed instructions for installing, operating, and troubleshooting the LEDVANCE LED Microdisk 4-inch downlight. It includes safety warnings, electrical connection steps, color temperature adjustment, and warranty information. Model: LEDMD4500ST9SC3WH.
Preview SubstiTUBE T8 Connected User Instructions
User instructions for the LEDVANCE SubstiTUBE T8 Connected, providing important information and notes regarding installation and operation. Includes details on compatibility, symbols, and installation procedures for both electromagnetic ballast and mains connections.
Preview LEDVANCE OPTI-SELECT UFO High Bay Luminaire Installation Guide
Detailed installation, operation, and safety guide for the LEDVANCE OPTI-SELECT UFO High Bay luminaire. Covers product features, mounting options, wiring, and troubleshooting.