This manual provides essential information for the safe and effective installation, operation, and maintenance of your SYLVANIA 48" T8 Octron Fluorescent Ecologic Lamp. These lamps are designed to provide exceptional color rendering with a 90 CRI, making them suitable for color-critical applications, and offer outstanding value. For optimal performance and longevity, please read and follow all instructions carefully.

Product Specifications

SpecificationValue
Model Number22433
Lamp TypeT8 Octron Fluorescent Ecologic Lamp
Wattage32 Watts
Length48 inches
Base TypeBi-Pin Base (G12)
Lumen Output2450 Lumens
Color Temperature4100K (Cool White)
Color Rendering Index (CRI)90
Average Lifetime (Instant Start)Up to 22,500 hours
Average Lifetime (Programmed Start)Up to 27,000 hours
Voltage120 Volts
Indoor/Outdoor UsageIndoor, Outdoor

Safety Information

Always turn off power at the circuit breaker before installing or removing fluorescent lamps. Handle lamps by the ends to avoid damaging the glass or internal components. Do not use in dimming circuits unless specifically rated for dimmable fluorescent lamps and compatible ballasts. Dispose of lamps according to local regulations, as they contain small amounts of mercury.

Setup and Installation

  1. Power Disconnection: Before beginning installation, ensure the power to the fixture is completely turned off at the circuit breaker or fuse box. Verify power is off using a voltage tester.
  2. Remove Old Lamp (if applicable): Carefully twist the old fluorescent tube 90 degrees to align the pins with the slots in the lampholders. Gently pull the lamp straight out from the fixture.
  3. Inspect Fixture: Check the lampholders for any damage or corrosion. Ensure they are clean and in good working order. Confirm the fixture uses a compatible T8 ballast (Rapid Start or Instant Start).
  4. Install New Lamp: Hold the new SYLVANIA T8 lamp by its ends. Align the pins on both ends of the lamp with the slots in the lampholders. Gently push the lamp into the lampholders until the pins are fully seated.
  5. Secure Lamp: Rotate the lamp 90 degrees until it locks securely into place. The lamp should feel firm and not wobble.
  6. Restore Power: Once the lamp is securely installed, restore power to the fixture at the circuit breaker.
  7. Test Operation: Turn on the light switch to confirm the lamp illuminates properly.
Bare SYLVANIA T8 Fluorescent Tube

Figure 2: A bare SYLVANIA T8 fluorescent tube, illustrating its cylindrical shape and bi-pin connectors at each end, ready for installation.

Operating Instructions

SYLVANIA T8 Octron Fluorescent Ecologic Lamps are designed for straightforward operation in compatible fluorescent fixtures. Once installed, simply activate the light switch connected to the fixture. The lamp will illuminate rapidly, providing consistent, high-quality light.

Maintenance

Minimal maintenance is required for your SYLVANIA T8 fluorescent lamp. Regular cleaning and proper handling will help ensure its long-term performance.

Troubleshooting

ProblemPossible CauseSolution
Lamp does not light up.
  • No power to fixture.
  • Lamp not properly seated.
  • Defective lamp.
  • Defective ballast.
  • Incorrect lamp type for ballast.
  • Check circuit breaker and wall switch.
  • Ensure lamp pins are fully inserted and twisted 90 degrees.
  • Replace lamp with a new one.
  • Consult a qualified electrician to check/replace ballast.
  • Verify lamp type (T8) matches ballast requirements.
Lamp flickers or dims.
  • Lamp nearing end of life.
  • Loose connection in lampholder.
  • Incompatible or failing ballast.
  • Low ambient temperature.
  • Replace lamp.
  • Reseat lamp firmly.
  • Consult a qualified electrician to check/replace ballast.
  • Ensure operating temperature is within recommended range.
Ends of lamp are dark.
  • Normal aging.
  • Frequent switching.
  • Improper ballast.
  • Replace lamp if light output is insufficient.
  • Minimize frequent on/off cycles.
  • Ensure ballast is compatible and functioning correctly.

Warranty and Support

For warranty information and technical support regarding your SYLVANIA T8 Octron Fluorescent Ecologic Lamp, please refer to the official LEDVANCE website or contact their customer service. The product warranty details can typically be found at www.sylvania.com.

For additional product information or to explore other lighting solutions, visit the LEDVANCE Store on Amazon: LEDVANCE Store.

Disposal Information

Fluorescent lamps contain a small amount of mercury and should be disposed of responsibly. Do not dispose of lamps in regular household trash. Please check with your local waste management authority for proper recycling or disposal options in your area. Many retailers and recycling centers offer collection programs for fluorescent lamps.

Related Documents - 22433

Preview LED Tube T8 EM Ultra Output S Installation and Operation Guide
Comprehensive guide for the installation and operation of the LEDVANCE LED Tube T8 EM Ultra Output S, covering retrofit and conversion installations, technical specifications, and safety information.
Preview LED TUBE T8 UNIVERSAL: Installation and Operation Guide
Comprehensive guide for installing and operating the LED TUBE T8 UNIVERSAL, a replacement for T8 fluorescent lamps. Includes technical specifications, retrofit, and conversion instructions.
Preview LED Tube T8 EM Ultra Output S Installation and Operation Guide
This document provides installation and operation instructions for the LEDVANCE LED Tube T8 EM Ultra Output S. It covers retrofitting and conversion for luminaires with electromagnetic control gear or direct AC mains connection, along with important safety and usage information.
Preview LED TUBE T8 EM ULTRA OUTPUT S: Installation Guide and Specifications
Comprehensive installation instructions, technical specifications, and compatibility details for the LEDVANCE LED TUBE T8 EM ULTRA OUTPUT S, a replacement for traditional T8 fluorescent lamps. Covers EM ballast and AC mains conversion.
Preview LED TUBE T8 EM V & EN ULTRA OUTPUT V: Installation and Operation Guide
Detailed installation and operation instructions for the LEDVANCE LED TUBE T8 EM V and T8 EN ULTRA OUTPUT V, providing guidance on retrofitting and conversion for T8 fluorescent lamp replacements.
Preview LEDVANCE T4 Compact Fluorescent Programmed Rapid Start Ballast LTP2X26CFUNVDM
Technical specifications, application details, and ordering information for the LEDVANCE T4 Compact Fluorescent Programmed Rapid Start Ballast (Model LTP2X26CFUNVDM), designed for 120-277V high efficiency lighting in commercial and institutional applications.