This user manual provides essential information for the safe and effective use of the Invacare Full Electric Bed Junction Box, model 1117178. Please read this manual thoroughly before attempting any installation, operation, or maintenance procedures. Adherence to these instructions will ensure proper functionality and prolong the lifespan of your product.

2. Product Overview

The Invacare Full Electric Bed Junction Box (part number 1117178) is a crucial replacement component designed for Invacare full electric homecare beds. It serves as the central control unit for the bed's electrical functions, facilitating the movement of the head, foot, and overall bed height. This specific model is compatible with Invacare full electric bed models such as the 5410IVc and 5490IVc foot spring sections.

Invacare Full Electric Bed Junction Box 1117178

Figure 2.1: Invacare Full Electric Bed Junction Box 1117178. This image displays the compact design of the junction box, highlighting its various connection ports and overall structure.

Invacare 'Making Life's Experiences Possible' lifestyle image

Figure 2.2: Invacare's commitment to enhancing daily life. This image illustrates a user comfortably utilizing an Invacare product in a home setting, reflecting the brand's focus on personal assistance products.

3. Safety Information

Always prioritize safety when handling electrical components. Failure to follow these safety guidelines may result in injury, damage to the product, or voiding of the warranty.

  • Disconnect Power: Always ensure the bed's power cord is unplugged from the electrical outlet before performing any installation, maintenance, or troubleshooting on the junction box or any part of the bed.
  • Qualified Personnel: Only qualified and authorized personnel should attempt repairs or complex installations.
  • Avoid Moisture: Keep the junction box and all electrical connections dry. Do not expose to water or excessive humidity.
  • Inspect for Damage: Before installation, visually inspect the junction box for any signs of physical damage, cracks, or frayed wires. Do not install a damaged unit.
  • Proper Connections: Ensure all cables are securely and correctly connected to their designated ports. Loose connections can lead to intermittent operation or electrical hazards.
  • Proposition 65 Warning: This product may expose you to chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

4. Setup and Installation

The Invacare Full Electric Bed Junction Box 1117178 is designed as a direct replacement part. Follow these steps for proper installation:

  1. Prepare the Bed: Ensure the full electric bed is unplugged from the wall outlet. Position the bed to allow easy access to the foot spring section where the junction box is typically located.
  2. Locate Existing Junction Box: Identify the current junction box on your Invacare full electric bed. It is usually found within the foot spring section, often near the motors or control cables.
  3. Disconnect Cables: Carefully disconnect all cables connected to the existing junction box. It is highly recommended to take a photograph or make a diagram of the existing connections before disconnecting to ensure correct re-connection. Note the numbering or color-coding of the ports and corresponding cables.
  4. Remove Old Unit: Unmount the old junction box from its position. This may involve unscrewing fasteners or releasing clips.
  5. Install New Unit: Mount the new Invacare 1117178 junction box in the same location. Secure it using the appropriate fasteners or clips.
  6. Connect Cables: Reconnect all cables to the new junction box, ensuring they are inserted into the correct ports as per your diagram or the original configuration. Ensure each connection is firm and secure.
  7. Final Check: Double-check all connections to ensure they are properly seated and there are no loose wires.
  8. Restore Power: Once all connections are secure, plug the bed's power cord back into the electrical outlet.

Note: For specific wiring diagrams or complex installations, refer to the service manual for your particular Invacare full electric bed model (e.g., 5410IVc, 5490IVc).

5. Operation

The Invacare Full Electric Bed Junction Box 1117178 is a passive component that facilitates the electrical control of your bed. Its operation is directly linked to the bed's hand pendant or control panel.

  • Once properly installed and connected, the junction box receives signals from the bed's control unit (e.g., hand pendant).
  • It then directs power to the appropriate motors to execute commands such as raising or lowering the head section, foot section, or the entire bed frame.
  • The junction box ensures that electrical currents are safely and efficiently distributed to the bed's various moving parts.

No direct user interaction with the junction box itself is required during normal bed operation.

6. Maintenance

Proper maintenance helps ensure the longevity and reliable performance of your junction box.

  • Regular Inspection: Periodically inspect the junction box and all connected cables for any signs of wear, fraying, cuts, or loose connections.
  • Keep Clean and Dry: Ensure the junction box remains clean and free from dust, debris, and moisture. Use a dry, soft cloth for cleaning. Do not use liquid cleaners directly on the unit.
  • Avoid Opening: The junction box is a sealed unit. Do not attempt to open its casing, as this can damage internal components, expose you to electrical hazards, and void the product warranty.
  • Cable Management: Ensure that all cables connected to the junction box are routed safely, without kinks, pinches, or excessive tension, to prevent damage.

7. Troubleshooting

If your Invacare Full Electric Bed is experiencing issues related to its electrical functions, the junction box may be a factor. Here are some common troubleshooting steps:

ProblemPossible CauseSolution
Bed does not respond to controls.No power to the bed; Loose cable connections; Faulty hand pendant; Faulty junction box.
  • 1. Ensure the bed is plugged into a working electrical outlet.
  • 2. Check all cables connected to the junction box and motors for secure connections.
  • 3. Test the hand pendant if possible (e.g., on another compatible bed).
  • 4. If other components are confirmed working, the junction box may need replacement.
Intermittent bed movement.Loose or damaged cable connections; Intermittent fault within the junction box.
  • 1. Inspect all cables and connections for damage or looseness. Re-seat them firmly.
  • 2. If the issue persists, the junction box may be failing and require replacement.
Unusual noises from the junction box.Internal component failure.Immediately disconnect power. Do not attempt to open the unit. Contact Invacare support for assistance.

If troubleshooting steps do not resolve the issue, it is recommended to contact Invacare customer support or a qualified service technician.

8. Specifications

AttributeDetail
Model Number1117178
ManufacturerInvacare
Product Dimensions14.21 x 7.99 x 4.53 inches
Weight0.01 ounces (approximate shipping weight)
CompatibilityInvacare Full Electric Homecare Beds (e.g., 5410IVc, 5490IVc)
Part TypeReplacement Control Box / Junction Box
Date First AvailableOctober 29, 2014

9. Warranty and Support

For information regarding the warranty of your Invacare Full Electric Bed Junction Box 1117178, or for technical assistance and support, please contact Invacare Corporation directly.

  • Manufacturer Contact: 1-800-333-6900
  • Invacare Store: For additional products and information, visit the Invacare Store on Amazon.

When contacting support, please have your product model number (1117178) and any relevant purchase information ready.

Related Documents - 1117178

Preview Invacare Bed Rail Entrapment Risk Notification Guide | Safety Information and Warnings
Comprehensive guide from Invacare detailing the risks of bed rail entrapment, safety precautions, benefits, and user guidelines for medical beds. Includes warnings and recommendations from the FDA.
Preview Bed Ends - Manual, Full / Semi Electric 5301IVC Parts List
Detailed parts list and assembly information for the 5301IVC Bed Ends, a manual, full, or semi-electric bed. Includes part numbers, descriptions, and quantities per assembly for head and foot end components.
Preview Invacare Homecare Beds Parts Catalog: Manual, Semi-Electric, Full Electric & Bariatric Models
Comprehensive parts catalog for Invacare Homecare Beds, including Manual, Semi-Electric, Full Electric, and Bariatric models like CareGuard. Find part numbers and specifications for Invacare beds.
Preview Invacare ICC Bed IH720 & SC900 LTC Parts Catalog | Service Manual
This official Invacare parts catalog provides comprehensive listings for the ICC Bed IH720 and SC900 LTC models. Discover detailed part numbers, descriptions, and specifications for all bed components and accessories, essential for maintenance and repair. Includes contact information for Invacare support.
Preview Invacare Medley Ergo and Medley Ergo Low User Manual
This user manual provides comprehensive instructions for the Invacare Medley Ergo and Medley Ergo Low medical beds. It covers essential safety guidelines, installation procedures, operational details, maintenance schedules, troubleshooting steps, and technical specifications to ensure safe and effective use of the medical beds.
Preview Invacare SB 755 Service Manual - Assembly, Setup, Maintenance, and Troubleshooting
Comprehensive service manual for the Invacare SB 755 bed, detailing assembly, setup procedures, maintenance schedules, cleaning, disinfection, lubrication, troubleshooting electrical issues, and disposal guidelines for qualified technicians.