Medline EvenCare G2

Medline EvenCare G2 Blood Glucose Monitoring System User Manual

This manual provides essential information for the safe and effective use of your Medline EvenCare G2 Blood Glucose Monitoring System. Please read all instructions carefully before use.

Product Overview

The Medline EvenCare G2 Blood Glucose Monitoring System is designed for convenient and accurate blood glucose testing. It provides rapid results and features voice guidance for ease of use.

Kit Contents

Your starter kit includes:

Medline EvenCare G2 Blood Glucose Monitor Starter Kit packaging and meter
The Medline EvenCare G2 Blood Glucose Monitor Starter Kit, including the meter and its retail packaging.
Contents of the Medline EvenCare G2 Blood Glucose Monitor Starter Kit laid out
All components of the EvenCare G2 Starter Kit, including the meter, test strips, lancing device, and lancets, arranged on a flat surface.

Setup

Battery Installation

The EvenCare G2 meter requires two AAA batteries.

  1. Locate the battery compartment on the back of the meter.
  2. Gently pull down the lever to open the compartment.
  3. Insert two AAA batteries, ensuring correct polarity.
  4. Close the battery compartment securely.

Initial Meter Settings (Date and Time)

It is crucial to set the correct date and time on your meter. If the date and time are not set, test results will not be stored in memory.

To access the setup screen:

An instructional video demonstrating the setup and use of the Medline EvenCare G2 Blood Glucose Monitoring System, including setting date and time, performing control solution tests, and blood glucose testing.

Operating the Meter: Blood Glucose Testing

Preparing the Lancing Device

If you are using a lancing device and lancet:

For fingertip testing, use the opaque adjustable cap. For alternate site testing (palm or forearm), use the clear cap. Consult your user manual for guidance on alternate site testing.

Performing a Blood Glucose Test

  1. Wash your hands with soap and warm water, then dry them thoroughly. If using an alcohol wipe, ensure the area is completely dry before sampling.
  2. Take out a new EvenCare G2 test strip from its bottle and immediately close the bottle cap.
  3. Insert the test strip into the meter. The meter will turn on and display a flashing blood drop and arrow icon. If voice guidance is enabled, it will announce, "Please apply blood onto the test strip."
  4. Use the lancing device to obtain a blood sample. For fingertip testing, hold the lancing device against the side of your fingertip and press the release button. For alternate site testing on your palm or forearm, apply and release pressure for a few seconds while keeping the lancing device in contact with the skin, then press the release button.
  5. Gently touch the tip of the test strip to the drop of blood at a slight angle. The test strip will draw the blood in. Keep the test strip in the blood drop until the meter beeps, indicating sufficient blood for testing.
  6. After approximately 6 seconds, your blood glucose test result will appear on the display screen and will be announced verbally if the voice feature is turned on.
  7. Your test result will be automatically stored in the meter's memory.
Medline EvenCare G2 meter, lancing device, and test strips
The EvenCare G2 meter, lancing device, and a vial of test strips, illustrating the main components used for blood glucose testing.

Control Solution Testing (Troubleshooting)

Control solution testing verifies that your EvenCare G2 meter and test strips are working correctly. Perform a control solution test when:

Important: Only use EvenCare G2 Glucose Control Solution and Test Strips with the EvenCare G2 meter. Other brands will produce inaccurate results.

Performing a Control Solution Test

You will need: EvenCare G2 Control Solution (Low and High), your EvenCare G2 Meter, and a new EvenCare G2 Blood Glucose Test Strip.

  1. Take out a new EvenCare G2 test strip and immediately close the bottle.
  2. Insert the test strip into the meter to turn it on.
  3. Wait for the flashing blood drop and arrow icons to appear. The meter will announce, "Please apply blood onto the test strip."
  4. Press the down arrow button to enter "L1" (Low Control Solution Testing). The meter will announce, "L1 Control Solution Test. Please apply control solution onto the test strip."
  5. Squeeze a drop of control solution onto a clean, dry, non-absorbent surface. Do not apply control solution directly from the bottle to the test strip.
  6. Gently touch the drop of control solution to the tip of the test strip. The meter will beep, and after 6 seconds, the result will appear.
  7. Compare the reading on the screen to the low range printed on the test strip bottle or its package.
  8. Properly discard the used test strip.
  9. Follow the same steps to perform a high control solution test.

Interpreting Control Solution Results

If the reading falls outside the low and high ranges printed on the test strip bottle or its package, please consult this user manual's troubleshooting section or contact customer support.

High or Low Blood Glucose Readings

If the meter displays results that are "HI" (High) or "LO" (Low), or if you get results more than 250 mg/dL or below 50 mg/dL:

Specifications

FeatureDetail
Model NumberMPH1545
Product Dimensions0.1 x 0.1 x 0.1 inches
Item Weight1.44 ounces
Batteries2 AAA batteries required
Battery Cell CompositionAlkaline
Operating Time6 Seconds
MemoryStores 300 test times with 7-, 14- and 30-day averaging
Voice GuidanceAvailable in English or Spanish

Important Safety Information & Disposal

Used lancets and strips are biohazardous materials and can transmit bloodborne diseases. Please dispose of them properly according to local government regulations to avoid injury or contamination.

Warranty

Specific warranty information is not provided in the product details. Please refer to the packaging or contact Medline customer support for warranty details.

Support

For technical assistance or further inquiries, please contact Medline's Technical Service Center.

Medline Technical Service Center: 1-866-274-2131

Available Monday through Friday, between 8:00 AM and 5:00 PM Central Time.

For all other times, please contact your healthcare provider.

Related Documents - EvenCare G2

Preview Medline Blood Pressure Monitor with Bluetooth® User Manual
User's manual for the Medline Blood Pressure Monitor with Bluetooth®, detailing its features, setup, usage, and safety information. Learn how to measure blood pressure, sync data with the Medline Health App, and understand blood pressure readings.
Preview Medline MDS4001 Series Blood Pressure Monitor User's Manual
User's manual for Medline MDS4001 series digital blood pressure monitors, covering setup, operation, safety, accuracy, and troubleshooting for home health monitoring.
Preview Medline MDS5001 Automatic Blood Pressure Monitor User's Manual
User's manual for the Medline MDS5001 Automatic Blood Pressure Monitor, detailing setup, operation, accurate measurement techniques, and troubleshooting for home health monitoring.
Preview Medline Automatic Digital Blood Pressure Monitor User Manual and Quick Start Guide
Comprehensive guide for the Medline Automatic Digital Blood Pressure Monitor (Models MDS4001, MDS4001LA, MDS4001PLUS, MDS4001LAT, MDS4001U), covering setup, usage, measurement tips, troubleshooting, and specifications. Includes quick start instructions.
Preview Medline MDS5001 Automatic Digital Blood Pressure Monitor Quick Start Guide
This guide provides essential instructions for setting up and using the Medline MDS5001 Automatic Digital Blood Pressure Monitor. Learn how to install batteries, set the date and time, correctly place the cuff, position your body, and begin a measurement. Includes a troubleshooting section for common issues.
Preview Medline MDS4003 Wrist Blood Pressure Monitor User Guide
Comprehensive user guide for the Medline MDS4003 Wrist Blood Pressure Monitor, covering setup, operation, measurement techniques, data management, troubleshooting, safety precautions, and technical specifications. This document provides detailed instructions for accurate blood pressure and pulse rate monitoring.