Amerec 9006-123 12KW Commercial Steam Boiler Instruction Manual

Model: 9006-123 | Brand: Amerec

1. Introduction

This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Amerec 9006-123 12KW Commercial Steam Boiler. Please read this manual thoroughly before attempting to install or operate the unit. Retain this manual for future reference.

The Amerec AI-12 commercial steam shower generator is designed for demanding commercial health club steam rooms, capable of serving spaces up to 550 cubic feet. It includes two 3/4" NPT steam heads. A control unit is required and sold separately.

2. Safety Information

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.

  • Always disconnect power before servicing the unit.
  • Ensure all electrical connections are made by a qualified electrician and comply with local and national electrical codes.
  • All plumbing connections must be made by a qualified plumber and comply with local and national plumbing codes.
  • Do not operate the steam boiler if it is damaged or malfunctioning.
  • Keep children and unauthorized personnel away from the unit during operation.
  • Steam is hot and can cause severe burns. Exercise extreme caution.

3. Product Overview

The Amerec 9006-123 is a robust commercial steam boiler designed for high-demand environments. It features durable construction and efficient steam generation for consistent performance.

Amerec 9006-123 12KW Commercial Steam Boiler

Figure 1: Amerec 9006-123 12KW Commercial Steam Boiler. This image shows the front and side view of the grey-colored steam boiler unit, featuring control panels with digital displays, various plumbing connections, and electrical conduits. Red-handled valves are visible on the left side, indicating water level monitoring.

4. Setup and Installation

Installation of the Amerec 9006-123 steam boiler requires professional expertise. It must be installed by a licensed electrician and plumber in accordance with all local and national codes.

4.1 Location Requirements

  • Install the unit in a dry, well-ventilated area, protected from freezing temperatures.
  • Ensure adequate clearance around the unit for maintenance and service.
  • The unit should be installed as close as possible to the steam room to minimize steam line length.

4.2 Electrical Connections

  • The unit operates on 208V, 3 Phase power.
  • Connect the boiler to a dedicated circuit with appropriate overcurrent protection.
  • Ensure proper grounding as per electrical codes.

4.3 Plumbing Connections

  • Connect a cold water supply line to the boiler's water inlet.
  • Install a drain line from the boiler to an approved floor drain.
  • Connect the steam line from the boiler to the steam heads within the steam room. Ensure proper pitch for condensate return.

5. Operating Instructions

The Amerec 9006-123 requires a separate control unit for operation. Refer to the control unit's manual for specific operating procedures.

  1. Power On: Ensure the main power supply to the boiler is switched on.
  2. Water Supply: Verify that the water supply valve to the boiler is open.
  3. Control Unit Activation: Use the external control unit (sold separately) to activate the steam generation cycle.
  4. Temperature Setting: Set the desired steam room temperature via the control unit.
  5. Steam Generation: The boiler will begin heating water to produce steam. This process may take several minutes depending on the initial water temperature and desired steam output.
  6. Power Off: To turn off the unit, use the external control unit or disconnect the main power supply.

Note: The boiler will automatically fill with water and maintain the water level during operation. Low water cut-off features are integrated for safety.

6. Maintenance

Regular maintenance is crucial for the longevity and efficient operation of your Amerec steam boiler. Always disconnect power before performing any maintenance.

6.1 Daily/Weekly Checks

  • Visually inspect the unit for any leaks or unusual noises.
  • Ensure the water level sight glass (if present) shows an appropriate water level.

6.2 Monthly/Quarterly Maintenance

  • Drain and Flush: Periodically drain the boiler to remove sediment buildup. Follow manufacturer guidelines for frequency based on water quality.
  • Element Inspection: Inspect heating elements for scale buildup. Descale as necessary using approved descaling solutions.
  • Safety Valve Check: Test the pressure relief valve to ensure it operates correctly.

6.3 Annual Professional Service

It is recommended to have the unit inspected and serviced annually by a qualified technician to ensure optimal performance and safety.

7. Troubleshooting

Before contacting customer support, review the following common issues and solutions.

Problem Possible Cause Solution
No steam production No power; water supply off; low water level; faulty heating element; control unit issue. Check power supply and circuit breaker; open water supply valve; check water level; consult technician for element/control unit.
Insufficient steam Scale buildup on elements; steam room too large; steam line leaks. Descale elements; verify steam room size is within specifications; check steam lines for leaks.
Water leaks Loose plumbing connections; damaged seals/gaskets. Tighten connections; replace damaged components.
Unit not filling with water Water supply off; clogged inlet filter; faulty fill valve. Open water supply; clean filter; consult technician for fill valve.

For issues not listed or if solutions do not resolve the problem, contact Amerec customer support or a qualified service technician.

8. Specifications

Feature Detail
Brand Amerec
Model Number 9006-123
Wattage 12000 watts (12KW)
Voltage 208 Volts
Phase 3 Phase
Style Indoor Installation
Steam Room Size Capacity Up to 550 cubic feet
Steam Heads Included Two 3/4" NPT
Control Unit Required, sold separately
UPC 646028001133

9. Warranty and Support

For warranty information, please refer to the documentation provided with your purchase or visit the official Amerec website. For technical support, replacement parts, or service inquiries, please contact Amerec customer service directly.

Amerec Contact Information: Please refer to the official Amerec website or your purchase documentation for the most current contact details.

Related Documents - 9006-123

Preview Amerec AK Steam Generator Installation and Service Instructions
A comprehensive guide for installing and servicing Amerec AK series steam generators (AK4.5, AK6, AK7.5, AK9, AK11, AK14). Covers safety precautions, mounting, plumbing, wiring, control options, and operational testing. Includes details for single and multi-generator systems.
Preview Amerec Commercial Steam Generator Installation Instructions - Models AI 12-48
Comprehensive installation guide for Amerec AI series commercial steam generators (models AI 12, AI 18, AI 24, AI 30, AI 36, AI 42, AI 48). Covers setup, plumbing, electrical, and operation for large steam rooms.
Preview Amerec ComfortFlo Steam Head Installation Guide
Detailed installation instructions for the Amerec ComfortFlo steam head, covering steam line requirements, safety warnings, and step-by-step assembly for steam generators and boilers.
Preview Amerec AK Series Steam Generator Specification Sheet
Detailed specification sheet for Amerec AK Series steam generators, covering performance features, control options (K60, KT60), sizing and rough-in guide, electrical and plumbing requirements, and installation instructions.
Preview Amerec Steam Boiler Connections and Aroma Pump Installation Guide
Comprehensive guide detailing the boiler connections and installation of Amerec aroma therapy pumps for steam systems. Covers dual-room setups, control panel wiring, pump connections, and essential notes for proper setup.
Preview Amerec Steambath Generator Rough-In Sheet and Installation Notes
This document provides essential rough-in dimensions, connection details, and installation guidelines for Amerec steambath generators, including models AK4, AK10, AK12, AK14, and 3K series.