1. Introduction
This manual provides comprehensive instructions for the proper setup, operation, and maintenance of your Sper Scientific 800016 Digital Humidity Temperature Monitor. This device is designed to simultaneously display both temperature and humidity readings, making it suitable for various environments such as laboratories, storage areas, and greenhouses.
Please read this manual thoroughly before using the device to ensure accurate measurements and safe operation.
2. Safety Information
- Do not expose the device to extreme temperatures or direct sunlight for prolonged periods.
- Avoid dropping the device or subjecting it to strong impacts.
- Do not immerse the device in water or other liquids.
- Use only the specified battery type (1 AAA battery).
- Keep batteries out of reach of children.
- Dispose of used batteries according to local regulations.
3. Package Contents
Verify that all items are present and in good condition:
- Sper Scientific 800016 Digital Humidity Temperature Monitor
- 1 AAA Battery
- Instruction Manual

Figure 3.1: Contents of the Sper Scientific 800016 package, including the monitor, battery, and instruction manual.
4. Product Overview
The Sper Scientific 800016 features a large dual display for simultaneous temperature and humidity readings, along with control buttons for various functions.

Figure 4.1: Front view of the monitor, showing the large digital display for temperature and humidity, along with the "MIN/MAX" and "RESET" buttons on the side.

Figure 4.2: Rear view of the monitor, illustrating the foldable kickstand for desktop use, the wall-mount hole, and the battery compartment.
4.1. Display Elements
- Upper Display: Shows current temperature.
- Lower Display: Shows current relative humidity.
- Humidity Indicator: A smiley face icon, potentially accompanied by text like "DRY", indicates the current humidity comfort level.
4.2. Buttons
- MIN/MAX Button: Press to view minimum and maximum recorded temperature and humidity values. Press again to cycle through MIN, MAX, and current readings.
- RESET Button: Press and hold to clear the recorded minimum and maximum values.
- °C/°F Button (Rear): Located on the back of the unit, press to switch between Celsius and Fahrenheit temperature units.
5. Setup
5.1. Battery Installation
- Locate the battery compartment cover on the back of the unit.
- Slide the cover open.
- Insert one AAA battery, ensuring correct polarity (+ and -).
- Replace the battery compartment cover.
5.2. Placement
The monitor can be placed on a flat surface or mounted on a wall.
- Desktop Placement: Extend the integrated kickstand on the back of the unit to stand it upright on a table or shelf.
- Wall Mounting: Use the keyhole slot on the back of the unit to hang it on a screw or nail securely fastened to a wall.
5.3. Initial Power-On
Once the battery is installed, the device will automatically power on and begin displaying current temperature and humidity readings. Allow a few minutes for the readings to stabilize.
6. Operation
6.1. Reading the Display
The large LCD simultaneously shows:
- Temperature: Displayed in the upper section, either in Celsius (°C) or Fahrenheit (°F).
- Relative Humidity: Displayed in the lower section, as a percentage (%).
6.2. Switching Temperature Units (°C/°F)
To change the temperature unit:
- Locate the small °C/°F button on the back of the unit.
- Press this button once to toggle between Celsius and Fahrenheit.
6.3. Viewing Minimum and Maximum Readings
The monitor records the lowest (MIN) and highest (MAX) temperature and humidity values since the last reset.
- Press the MIN/MAX button once to display the minimum recorded temperature and humidity.
- Press the MIN/MAX button a second time to display the maximum recorded temperature and humidity.
- Press the MIN/MAX button a third time to return to current readings.
6.4. Resetting Minimum and Maximum Readings
To clear the recorded MIN/MAX values and start a new recording cycle:
- While viewing either MIN or MAX readings, press and hold the RESET button for approximately 3 seconds. The display will briefly flash, indicating that the values have been reset to the current readings.
Alternatively, the device can be set to automatically reset every 24 hours. Refer to the original product documentation for specific instructions on enabling this feature if available, as it is not explicitly detailed in the provided data.
7. Maintenance
7.1. Cleaning
- Wipe the device with a soft, damp cloth.
- Do not use abrasive cleaners or solvents, as these may damage the display or casing.
7.2. Battery Replacement
When the display becomes dim or the device stops functioning, it is time to replace the battery. Follow the steps in Section 5.1 for battery installation.
7.3. Storage
If storing the device for an extended period, remove the battery to prevent leakage and potential damage.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No display or dim display | Dead or incorrectly installed battery | Replace battery with a new AAA battery, ensuring correct polarity. |
| Inaccurate readings | Sensor obstruction or extreme environmental conditions | Ensure sensors are clear. Move device to a stable environment away from direct heat sources, vents, or high humidity areas. |
| MIN/MAX values not resetting | RESET button not held long enough | Press and hold the RESET button for at least 3 seconds until the display flashes. |
9. Specifications
| Feature | Detail |
|---|---|
| Model Number | 800016 |
| Brand | Sper Scientific |
| Display | Dual LCD, 3-3/16 x 2½ inches |
| Upper Temperature Rating | 50 Degrees Celsius |
| Temperature Accuracy | +/- 0.2 Degrees Fahrenheit |
| Battery Type | 1 x AAA |
| Mounting Type | Wall Mount, Desktop Stand |
| Package Dimensions | 5.5 x 4.1 x 1 inches; 4 ounces |
| Country of Origin | China |
10. Warranty and Support
Sper Scientific products are designed for reliability and accuracy. For warranty information or technical support, please refer to the contact information provided with your purchase or visit the official Sper Scientific website.
Please retain your purchase receipt as proof of purchase for warranty claims.