The Hach 1408100 Nitrate-Nitrite Test Kit, Model NI-12, is designed for determining nitrate and nitrite concentrations. This comprehensive kit includes all necessary reagents and test apparatus, conveniently housed within a durable plastic carrying case.

Key features include:

  • Achieve fast results with an easy-to-carry test kit.
  • Includes reagents and test apparatus.
  • Provided in a plastic carrying case for portability and organization.
Hach 1408100 Nitrate-Nitrite Test Kit components including a blue carrying case, test tubes, reagent packets, and a dropper.

Figure 1: Components of the Hach 1408100 Nitrate-Nitrite Test Kit. Shown are the blue carrying case, test tubes, a black test block, reagent packets, and a dropper, along with color comparator discs.

Setup and Preparation

  1. Unpack the Kit: Carefully open the plastic carrying case and remove all components. Verify that all items listed in the kit contents (refer to packaging or product documentation) are present and undamaged.

  2. Identify Components: Familiarize yourself with the test tubes, reagent packets, color comparator discs, and any other apparatus included.

  3. Prepare Workspace: Ensure you have a clean, well-lit, and stable surface for performing tests. Keep all necessary components within easy reach.

  4. Safety Precautions: Always wear appropriate personal protective equipment (PPE) such as safety glasses and gloves when handling chemical reagents. Refer to the Safety Data Sheets (SDS) for specific reagent handling instructions and emergency procedures.

Operating Instructions

The following general steps outline the procedure for using the Nitrate-Nitrite Test Kit. Always refer to the specific instructions provided with your reagent packets for precise measurement protocols, as procedures may vary slightly depending on the analyte (nitrate or nitrite) and method.

  1. Sample Collection: Collect a representative water sample in a clean test tube. Ensure the sample is free from suspended solids that could interfere with the test.

  2. Reagent Addition: Add the specified amount of reagent(s) to the sample. This typically involves adding the contents of one or more reagent packets. Close the test tube securely with a stopper.

  3. Mixing: Invert the test tube several times to thoroughly mix the sample and reagents. Avoid shaking vigorously unless specified, as this can introduce air bubbles.

  4. Reaction Time: Allow the sample to react for the prescribed time. This reaction time is crucial for color development and accurate results. Do not disturb the sample during this period.

  5. Color Comparison: After the reaction time, place the reacted sample tube into the color comparator. Compare the color of the reacted sample with the color standards on the comparator disc. Rotate the disc until a color match is found.

  6. Record Results: Read the concentration value corresponding to the matched color on the comparator disc. Record your results immediately.

  7. Disposal: Properly dispose of reacted samples and used reagents according to local regulations and safety guidelines. Do not pour chemicals down the drain unless specifically instructed.

Note: For specific nitrate or nitrite testing procedures, consult the detailed instructions provided within the reagent packets or the official Hach documentation for Model NI-12.

Maintenance and Storage

  • Cleaning: After each use, thoroughly rinse all test tubes and apparatus with distilled or deionized water. Allow them to air dry completely before storing.

  • Reagent Storage: Store reagent packets in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure packets are sealed until ready for use to maintain their integrity and shelf life.

  • Kit Storage: Keep the entire test kit in its plastic carrying case when not in use. Store in a secure location to prevent damage or contamination.

  • Expiration Dates: Periodically check the expiration dates on all reagent packets. Discard expired reagents as they may yield inaccurate results.

Troubleshooting

ProblemPossible CauseSolution
Inaccurate or inconsistent resultsExpired reagents, improper mixing, incorrect reaction time, contaminated glassware, incorrect sample collection.Check reagent expiration dates. Ensure thorough mixing. Adhere strictly to reaction times. Clean glassware thoroughly. Collect a fresh, representative sample.
No color developmentMissing reagent, incorrect reagent addition order, sample pH outside optimal range, expired reagents.Verify all reagents were added correctly. Follow the exact order of addition. Check sample pH if applicable. Use fresh reagents.
Difficulty matching colorPoor lighting, turbid sample, color outside kit's range.Perform test in well-lit area. Filter turbid samples if possible. Dilute sample if concentration is too high (and adjust final reading accordingly).

Specifications

AttributeValue
Model Number1408100
Product NameNitrate-Nitrite Test Kit
BrandHACH
Package Dimensions9.69 x 7.48 x 5.91 inches
Item Weight2.15 Pounds
ManufacturerHACH COMPANY
ASINB00N3YJVN2
First Available DateAugust 28, 2014

Warranty and Support

For detailed warranty information and technical support, please refer to the official documentation included with your Hach 1408100 Nitrate-Nitrite Test Kit or visit the official Hach website. Contact information for customer service and technical assistance is typically provided on the product packaging or within the kit's accompanying literature.

You may also find additional resources and frequently asked questions on the HACH Store on Amazon.

© 2024 HACH. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.