This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Traulsen G11010 Dealer's Choice Single Section Reach-In Refrigerator. This unit is a self-contained display refrigerator with a full-height glass door, designed for commercial food service applications. It features microprocessor control, stainless steel exterior, anodized aluminum interior, and epoxy-coated shelves.

Please read this manual thoroughly before installing or operating the unit. Keep this manual for future reference.

Safety Information

Always observe basic safety precautions when using electrical appliances to reduce the risk of fire, electrical shock, and injury to persons.

  • Ensure the unit is properly grounded.
  • Do not operate the unit with a damaged cord or plug.
  • Do not allow children to play on or in the refrigerator.
  • Disconnect power before performing any maintenance or cleaning.
  • Refer all servicing to qualified service personnel.

Setup

Unpacking

Carefully remove all packaging materials. Inspect the unit for any shipping damage. Report any damage to the carrier immediately.

Placement

Position the refrigerator on a level, sturdy surface capable of supporting its weight (approximately 395 pounds). Ensure adequate ventilation around the unit. Maintain a minimum of 6 inches of clearance from walls or other equipment for proper airflow to the condenser. Avoid placing the unit in direct sunlight or near heat-generating appliances.

The unit is equipped with 6-inch high casters for mobility. Ensure casters are locked once the unit is in its final position to prevent accidental movement.

Electrical Connection

The Traulsen G11010 operates on 115V/60Hz/1ph power, drawing 7.4 amps. It is equipped with a NEMA 5-15P plug. Connect the unit to a dedicated, properly grounded electrical outlet. Do not use extension cords or adapter plugs.

Operating Instructions

Initial Startup

After connecting to power, allow the unit to run for at least 2-4 hours empty to reach the desired operating temperature before loading with products.

Microprocessor Control

The refrigerator is equipped with a microprocessor control system for precise temperature management. Refer to the control panel for current temperature display and adjustment options. Consult the separate microprocessor control guide for detailed programming instructions, including setting temperature set points, defrost cycles, and alarms.

Loading the Refrigerator

Distribute products evenly on the three factory-installed epoxy-coated shelves. Do not block the internal air circulation vents. Overloading the unit or blocking airflow can impair cooling performance.

Internal Lighting

The unit features internal lighting to illuminate the contents. The light switch is typically located near the control panel or inside the cabinet. Turn off lights when not needed to conserve energy.

Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your refrigerator.

Cleaning

  • Interior: Clean the interior regularly with a mild soap and water solution. Rinse thoroughly and dry. Do not use abrasive cleaners or steel wool.
  • Exterior: Wipe down the stainless steel front and anodized aluminum sides with a soft cloth and a non-abrasive cleaner. For the glass door, use a standard glass cleaner.
  • Gaskets: Inspect door gaskets for tears or damage. Clean gaskets regularly with warm, soapy water to maintain a proper seal.

Condenser Coil Cleaning

The condenser coil should be cleaned every 30-90 days, depending on the operating environment. A dirty condenser coil reduces efficiency and can lead to compressor failure. Disconnect power before cleaning. Use a stiff brush or vacuum cleaner to remove dust and debris from the coil fins.

Troubleshooting

Problem Possible Cause Solution
Unit not cooling No power; Dirty condenser coil; Door not sealing properly; Thermostat set too high. Check power supply; Clean condenser coil; Inspect and clean door gasket; Adjust thermostat setting.
Excessive noise Loose components; Fan motor issue; Unit not level. Check for loose parts; Contact service technician; Level the unit.
Water on floor Clogged drain line; Drain pan overflowing. Clear drain line; Check drain pan for proper positioning.

For issues not listed or if solutions do not resolve the problem, contact a qualified service technician.

Specifications

Traulsen G11010 Single Section Reach-In Refrigerator with open glass door

Image: Traulsen G11010 Single Section Reach-In Refrigerator with its full-height glass door open, revealing three epoxy-coated shelves inside. The unit is on casters.

Feature Detail
Model G11010
Capacity 24.2 cu. ft.
Dimensions (D x W x H) 35"D x 29.88"W x 83.25"H
Weight 395 Pounds
Electrical 115V/60Hz/1ph, 7.4 Amps, NEMA 5-15P
Shelves (3) Epoxy Coated, Factory Installed
Door Type Full-Height Glass Door (Hinged Right)
Exterior Material Stainless Steel Front, Anodized Aluminum Sides
Interior Material Anodized Aluminum
Casters 6" High Casters
Compressor 1/3 HP
Certifications cULus, NSF

Warranty & Support

The Traulsen G11010 comes with a standard warranty:

  • Service/Labor: 3 years
  • Compressor: 5 years

For warranty claims, technical support, or to locate authorized service providers, please contact Traulsen customer service. Refer to your purchase documentation for specific contact details or visit the official Traulsen website.

© 2024 Traulsen. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.