1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the Sloan SF-2300 Sensor Activated Touch-Free Faucet. Designed for commercial applications, this faucet offers reliable infrared sensor activation, promoting hygiene and water efficiency. Please read this manual thoroughly before installation and operation to ensure proper function and longevity of the product.
2. Safety Information
Always adhere to local plumbing and electrical codes during installation. Disconnect power before servicing. Ensure all connections are secure to prevent leaks. This product is designed for use with potable water only. Do not use abrasive cleaners on the polished chrome finish.
3. Package Contents
Verify that all components are present before beginning installation:
- Sloan SF-2300 Faucet Body (Polished Chrome)
- Control Box with Filtered Solenoid Valve
- 36-inch Sensor Cable
- 24-inch Flex Hose
- Mounting Hardware (washers, nuts, screws)
- Installation Guide

Image 3.1: Sloan SF-2300 Faucet with included mounting hardware.
4. Specifications
| Feature | Specification |
|---|---|
| Model Number | SF-2300 (Part Number: 3362116) |
| Flow Rate | 0.5 GPM (Gallons Per Minute) |
| Power Source | Hardwired-Powered |
| Mounting Type | Deck-Mounted |
| Finish | Polished Chrome |
| Sensor Cable Length | 36 inches |
| Flex Hose Length | 24 inches |
| Compliance | ADA Compliant |
| Item Weight | 4.9 pounds |
5. Installation (Setup)
Follow these steps for proper installation of your Sloan SF-2300 faucet:
- Prepare the Mounting Surface: Ensure the deck surface is clean, dry, and free of debris. The faucet is designed for deck-mounted installation.
- Mount the Faucet Body: Place the faucet body onto the deck opening. Secure it from underneath using the provided mounting hardware (washers and nuts). Ensure the faucet is oriented correctly.
- Connect the Control Box: The control box houses the solenoid valve and sensor electronics. Mount the control box in an accessible location under the sink, ensuring it is protected from direct water exposure.
- Connect Sensor Cable: Connect the 36-inch sensor cable from the faucet body to the designated port on the control box. Ensure a secure connection.
- Connect Water Supply: Attach the 24-inch flex hose from the faucet to the water supply line. Connect the other end of the flex hose to the control box inlet. Ensure all plumbing connections are tight to prevent leaks.
- Connect Power: This faucet is hardwired-powered. Connect the power supply to the control box according to local electrical codes. It is recommended that a qualified electrician perform this step.
- Test for Leaks and Functionality: Turn on the water supply and check for any leaks. Restore power and test the sensor activation.

Image 5.1: Internal view of the control box, showing wiring and solenoid valve.

Image 5.2: Exterior of the control box, indicating sensor range adjustment.
6. Operation
The Sloan SF-2300 faucet operates using an infrared sensor for touch-free activation.
- Automatic Activation: Place hands within the sensor's detection range. The water will flow automatically.
- Automatic Shut-off: Remove hands from the sensor's detection range. The water flow will stop automatically after a brief delay.
- Adjustable Sensor Range: The infrared sensor range can be adjusted to suit specific installation environments. Refer to the control box label (Image 5.2) for instructions on how to select the sensor range. Typically, a button or switch on the control box allows for cycling through different detection distances.

Image 6.1: Front view of the Sloan SF-2300 faucet, highlighting the sensor location.
7. Maintenance
Regular maintenance ensures optimal performance and extends the life of your faucet.
- Cleaning the Faucet: Clean the polished chrome finish with a soft cloth and mild, non-abrasive cleaner. Avoid harsh chemicals or abrasive pads, which can damage the finish.
- Sensor Cleaning: Keep the sensor window on the faucet body clean and free of obstructions. Wipe gently with a soft, damp cloth.
- Solenoid Filter Maintenance: The filtered solenoid valve includes a serviceable strainer filter. Periodically inspect and clean this filter to ensure a clean water supply and prevent debris from affecting faucet operation. To access, turn off the water supply, disconnect the flex hose from the control box, and carefully remove the filter for cleaning.
- Power Supply Check: Ensure the hardwired power connection is secure and free from damage.
8. Troubleshooting
If you encounter issues with your Sloan SF-2300 faucet, refer to the following common troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| No water flow |
|
|
| Continuous water flow |
|
|
| Intermittent water flow |
|
|
9. Warranty and Support
For warranty information or technical assistance, please contact Sloan customer support. Keep your purchase receipt and model number (SF-2300, Part Number: 3362116) readily available when contacting support.
Sloan Contact Information:
- Visit the official Sloan website for support resources.
- Refer to the contact details provided with your product packaging.