Texecom CFC-0001

Texecom Veritas R8 Burglar Alarm Control Panel User Manual

Model: CFC-0001

Introduction

This manual provides essential information for the setup, operation, and maintenance of your Texecom Veritas R8 Burglar Alarm Control Panel. This system is designed to provide reliable security for domestic or small office environments. Please read these instructions carefully before installation and use.

Texecom Veritas R8 Burglar Alarm Control Panel with keypad

Image showing the Texecom Veritas R8 Burglar Alarm Control Panel. The main white unit is visible, with a smaller, hinged keypad unit attached below it. The keypad features numerical buttons (0-9), 'FULL', 'PART', 'PROG', 'RESET' buttons, and indicator lights for zones and system status.

Setup and Installation

The Texecom Veritas R8 is designed for wireless DIY installation. However, for optimal performance and to ensure correct programming, it is recommended to consult the full installation manual available from the manufacturer's website or seek assistance from a qualified professional.

Keypad Connection

The system supports connection of up to six backlit remote keypads. Ensure all keypads are securely connected according to the wiring diagrams provided in the comprehensive installation guide.

Zone Configuration

The control panel features 8 fully programmable zones plus a tamper zone. Each zone must be configured to monitor specific areas or sensors within your property. Refer to the detailed programming instructions for zone setup.

Operating Instructions

The Veritas R8 control panel provides intuitive operation through its integrated keypad.

Arming the System

  • To FULL SET: Enter your user code, then press the FULL button.
  • To PART SET: Enter your user code, then press the PART button. The system offers 2 programmable part-set suites.

Disarming the System

To disarm the system and silence the alarm, enter your user code.

Resetting the System

After an alarm event, to reset the system, enter your user code, then press the RESET button.

Panic Alarm (PA)

A keypad Panic Alarm (PA) option is available. To activate, press buttons 3 and 9 together simultaneously.

Maintenance

Regular maintenance ensures the longevity and reliability of your alarm system.

  • Service Timers: The system includes date-programmable service timers to remind you when routine maintenance is due. Ensure these are set and adhered to.
  • Cleaning: Periodically wipe the control panel and keypads with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
  • Battery Check: Although the main unit does not include batteries, ensure any connected wireless sensors or keypads with batteries are checked and replaced as per their individual instructions.

Troubleshooting

Should you encounter issues with your Veritas R8 control panel, consider the following:

  • System Not Arming: Check all zones for open circuits or tamper conditions. Ensure all doors and windows are closed.
  • False Alarms: Investigate potential causes such as faulty sensors, incorrect zone programming, or environmental factors.
  • Anti-Code Reset: The system features a built-in anti-code reset function for specific fault conditions. Refer to the full manual for details on its use.
  • Soak Test Suite: Utilize the soak test suite feature to thoroughly test the system's functionality and identify intermittent faults.
  • Power Issues: Ensure the corded electric power source is stable and connected correctly.

For complex issues or programming difficulties, refer to the comprehensive installation and programming manual or contact technical support.

Specifications

ManufacturerTexecom
Part NumberCFC-0001
Item Model NumberCFC-0001
Product Dimensions11.66 x 9.3 x 8.99 cm
Item Weight1.78 kg
ColourWhite
Power SourceCorded Electric
Installation MethodWireless DIY
Item Package Quantity1
Batteries Included?No
Batteries Required?No
Zones8 fully programmable zones + tamper
Part-Set Suites2 programmable
Keypad SupportUp to six backlit remote keypads

Warranty Information

Warranty terms and conditions for the Texecom Veritas R8 Burglar Alarm Control Panel are provided by the manufacturer. Please refer to the documentation included with your product or visit the official Texecom website for detailed warranty information and registration procedures. Keep your proof of purchase for warranty claims.

Support

For technical assistance, programming queries, or further support, please contact Texecom customer service or consult their official website. Access to the full installation and programming manual is highly recommended for advanced configurations.