1. Introduction

This manual provides essential information for the safe installation, operation, and maintenance of your FABER 2152 SRM LG A90 built-in cooker hood. Please read these instructions carefully before using the appliance and retain them for future reference.

2. Safety Information

Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and personal injury.

  • Ensure the electrical installation complies with local regulations.
  • Do not operate the hood without the metallic grease filters in place.
  • Regularly clean the grease filters to prevent fire hazards.
  • Do not flambé under the cooker hood.
  • Ensure adequate ventilation in the room when the hood is used simultaneously with other appliances burning gas or other fuels.
  • Disconnect the appliance from the power supply before any cleaning or maintenance.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

3. Package Contents

Verify that all components are present and undamaged upon unpacking:

  • FABER 2152 SRM LG A90 Built-in Hood unit
  • Metallic grease filters (pre-installed)
  • Instruction Manual
  • Mounting hardware (screws, anchors)

Note: Carbon filters for recirculation mode are not included and must be purchased separately if required.

4. Setup and Installation

The FABER 2152 SRM LG A90 is an under-cabinet built-in hood designed for integration into kitchen cabinetry. It can operate in extraction (ducted) or recirculation (filtering) mode.

4.1. Installation Overview

Refer to the dimensional drawing for precise measurements and clearances required for installation.

Dimensional drawing of FABER 2152 SRM LG A90 built-in hood with measurements in millimeters.

Figure 1: Dimensional drawing of the FABER 2152 SRM LG A90 built-in hood. Dimensions include a width of 898mm, depth of 300mm to 490mm (adjustable front panel), height of 150mm, and a 120mm diameter air outlet.

  • Ensure the cabinet opening matches the hood's dimensions (approximately 900mm width).
  • The hood is designed for a 120mm diameter air outlet for ducted operation.
  • For recirculation mode, install optional carbon filters (not included) and ensure the air outlet is directed back into the kitchen.
  • Securely fasten the hood to the cabinet structure using appropriate screws and anchors.
  • Connect the hood to a suitable electrical outlet.

4.2. Electrical Connection

The appliance must be connected to the mains supply by a qualified electrician. Ensure the voltage and frequency correspond to the ratings on the appliance's data plate.

5. Operating Instructions

The FABER 2152 SRM LG A90 features electromechanical controls for fan speed and lighting.

Close-up view of the electromechanical controls and LED lights on the FABER 2152 SRM LG A90 hood.

Figure 2: Electromechanical controls and LED lighting on the hood.

  • Fan Speed Control: Use the push-button controls to select one of the three available fan speeds (1, 2, 3). Speed 1 is for light cooking, Speed 2 for normal cooking, and Speed 3 for intensive cooking or strong odors.
  • Lighting Control: Press the light button to turn the LED lamps on or off. The hood is equipped with 2 LED lamps for illuminating the cooking area.

For optimal performance, switch on the hood a few minutes before cooking and leave it running for approximately 10-15 minutes after cooking to clear residual odors.

6. Maintenance

Regular maintenance ensures the longevity and efficient operation of your cooker hood.

6.1. Cleaning the Metallic Grease Filters

The metallic grease filters capture grease particles from cooking fumes. They should be cleaned regularly, at least once a month, depending on usage.

  1. Disconnect the hood from the power supply.
  2. Remove the metallic grease filters by releasing their latches.
  3. Wash the filters by hand in hot water with a mild detergent or in a dishwasher on a low-temperature cycle.
  4. Ensure the filters are completely dry before re-installing them.
  5. Re-install the filters, ensuring they are securely latched.
FABER 2152 SRM LG A90 built-in hood with metallic grease filters visible.

Figure 3: FABER 2152 SRM LG A90 built-in hood, showing the metallic grease filters.

6.2. Replacing Carbon Filters (Recirculation Mode Only)

If your hood is operating in recirculation mode, carbon filters (not included) are used to absorb odors. These filters cannot be washed and must be replaced every 3-6 months, depending on usage.

  1. Disconnect the hood from the power supply.
  2. Remove the metallic grease filters.
  3. Remove the saturated carbon filters according to their specific mounting mechanism.
  4. Install new carbon filters, ensuring they are correctly positioned.
  5. Re-install the metallic grease filters.

6.3. Cleaning the Exterior

Clean the exterior surfaces of the hood with a soft cloth dampened with a mild, non-abrasive detergent. Avoid using abrasive cleaners, alcohol, or corrosive products that could damage the finish.

7. Troubleshooting

Before contacting technical assistance, check the following common issues:

ProblemPossible CauseSolution
Hood does not turn on.No power supply.Check if the plug is correctly inserted and the circuit breaker is on.
Poor suction performance.Grease filters are clogged.Clean the metallic grease filters.
Carbon filters are saturated (recirculation mode).Replace the carbon filters.
Air outlet duct is obstructed or too long/narrow.Check and clear any obstructions in the ducting. Ensure ducting meets installation requirements.
Excessive noise.Loose components or improper installation.Check all mounting screws and ensure filters are correctly installed.
Ducting issues (e.g., too many bends, wrong diameter).Review ducting installation.

8. Specifications

FeatureDetail
Model2152 SRM LG A90
BrandFABER
TypeBuilt-in Under-cabinet Hood
FinishLight Grey
MaterialMetal
Width900 mm
ControlsElectromechanical
Number of Speeds3
Lighting2 LED lamps
Grease Filter TypeMetallic (Baffle)
Ventilation TypeExtraction (Ducted), Convertible to Recirculation
Air Outlet Diameter120 mm
Motors2
Max Suction Capacity (IEC)290 m³/h
Max Pressure240 Pa
Max Power Consumption190 W
Max Noise Level73 dB(A)
Energy ClassE
Manufacturer Part Number315.0547.815

9. Warranty and Support

This FABER appliance is covered by a manufacturer's warranty. Please refer to the warranty card included with your product for specific terms and conditions.

  • EU Spare Parts Availability: Spare parts for this model are available for a duration of 5 years from the date of purchase.
  • For technical assistance, repairs, or to purchase spare parts (such as carbon filters), please contact your retailer or an authorized FABER service center.
  • When contacting support, please have your model number (2152) and manufacturer part number (315.0547.815) ready.

© 2024 FABER. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.