1. Introduction

This manual provides essential information for the correct installation, operation, and maintenance of the Eliwell IDPlus 902 temperature controller. The IDPlus 902 is a versatile digital thermostat designed for refrigeration and heating applications, compatible with NTC, PTC, and PT1000 temperature sensors, operating on a 230Vac power supply.

Please read this manual carefully before installing or operating the device to ensure safe and efficient performance. Keep this manual for future reference.

2. Safety Information

  • Electrical Hazard: Disconnect power supply before performing any wiring or maintenance. Only qualified personnel should perform electrical connections.
  • Voltage: Ensure the power supply voltage matches the device's specifications (230Vac).
  • Environment: Do not expose the device to water, excessive humidity, or corrosive agents. Install in a well-ventilated area.
  • Mounting: Securely mount the controller according to the instructions to prevent accidental dislodgement.
  • Sensor Compatibility: Use only compatible NTC, PTC, or PT1000 sensors as specified.

3. Product Overview

The Eliwell IDPlus 902 is a single-stage temperature controller featuring a clear digital display and intuitive button interface. It is designed for precise temperature management in various industrial and commercial applications, particularly in refrigeration units. Key features include:

  • Universal sensor input (NTC, PTC, PT1000 selectable).
  • One relay output for compressor or heating control (8A).
  • Adjustable setpoint and differential.
  • Defrost management capabilities (if configured).
  • Front panel mounting.
Eliwell IDPlus 902 Front Panel

Figure 1: Front view of the Eliwell IDPlus 902 temperature controller, showing the display and control buttons.

4. Installation (Setup)

4.1. Mounting

The IDPlus 902 is designed for panel mounting. Cut a rectangular opening of 71 x 29 mm (2.80 x 1.14 inches) in the panel. Insert the controller from the front and secure it using the provided side clips.

4.2. Electrical Connections

Refer to the wiring diagram below for proper electrical connections. Ensure all connections are secure and comply with local electrical codes.

Eliwell IDPlus 902 Wiring Diagram

Figure 2: Typical wiring diagram for the Eliwell IDPlus 902. Connect power to terminals 7 and 8 (230Vac). Connect the temperature sensor to terminals 1 and 2. The relay output for the load (e.g., compressor) is connected to terminals 5 (common) and 6 (normally open).

  • Power Supply (230Vac): Connect to terminals 7 and 8.
  • Temperature Sensor: Connect the NTC, PTC, or PT1000 sensor to terminals 1 and 2. Ensure correct polarity for PT1000 if applicable (though typically 2-wire).
  • Relay Output (Load): Connect the controlled device (e.g., compressor, heater) to terminals 5 (common) and 6 (normally open contact).

5. Operating Instructions

5.1. Display

The display shows the current temperature measured by the probe. During parameter setting, it shows parameter codes and values.

5.2. Button Functions

ButtonFunction (Short Press)Function (Long Press)
SETView/Modify SetpointAccess Parameter Menu
UP (▲)Increase ValueManual Defrost (if configured)
DOWN (▼)Decrease ValueView Auxiliary Probe (if configured)

5.3. Setting the Setpoint

  1. Press the SET button briefly. The current setpoint value will flash.
  2. Use the UP (▲) or DOWN (▼) buttons to adjust the setpoint to the desired temperature.
  3. Press the SET button again to confirm and save the new setpoint. The display will return to showing the current temperature.

6. Parameter Settings

The IDPlus 902 has a comprehensive menu of configurable parameters to fine-tune its operation. These parameters control aspects such as sensor type, differential, calibration, defrost cycles, and alarm thresholds.

6.1. Accessing the Parameter Menu

  1. Press and hold the SET button for approximately 3 seconds until "PS" (Parameter Set) appears on the display.
  2. Use the UP (▲) or DOWN (▼) buttons to navigate through the parameter codes (e.g., "Hy" for hysteresis/differential, "P1" for probe type).
  3. Once the desired parameter code is displayed, press SET briefly to view its current value.
  4. Use the UP (▲) or DOWN (▼) buttons to modify the value.
  5. Press SET again to confirm and save the new value.
  6. To exit the parameter menu, press and hold the SET button for 3 seconds, or wait for the timeout (approximately 30 seconds) for the display to return to normal operation.

Note: A detailed list of all parameters and their functions can be found in the full technical manual, typically available from the manufacturer's website or included with the product packaging. Incorrect parameter settings can lead to improper operation or damage.

7. Maintenance

The Eliwell IDPlus 902 is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure its longevity and accuracy.

  • Cleaning: Clean the front panel with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the device.
  • Connections: Periodically check all electrical connections for tightness and signs of corrosion.
  • Sensor: Ensure the temperature sensor is clean and properly positioned in the area where temperature is to be controlled.
  • Ventilation: Ensure adequate airflow around the device if installed in an enclosure to prevent overheating.

8. Troubleshooting

If the controller is not functioning as expected, refer to the following common issues and solutions:

ProblemPossible CauseSolution
Display shows "Err" or "Prt"Sensor fault (open circuit, short circuit, or out of range).Check sensor connections. Replace sensor if faulty. Verify sensor type parameter matches installed sensor.
Controller not switching loadIncorrect setpoint/differential, wiring error, or faulty relay.Verify setpoint and differential settings. Check load wiring. Test the relay (if possible, by a qualified technician).
Display is blankNo power supply.Check power connections (terminals 7 and 8) and ensure 230Vac is present. Check fuses if applicable.
Temperature reading is inaccurateSensor calibration error, incorrect sensor type selected, or faulty sensor.Check sensor type parameter. Perform sensor calibration if necessary. Replace sensor.

9. Specifications

FeatureSpecification
ModelIDPlus 902
Power Supply230Vac, 50/60Hz
Sensor Inputs1 x Universal (NTC, PTC, PT1000 selectable)
Relay Output1 x SPDT 8A @ 250Vac (resistive load)
Display3-digit + sign, red LED
MountingPanel mount, 71 x 29 mm cutout
Operating Temperature0 to 50°C (32 to 122°F)
Storage Temperature-20 to 70°C (-4 to 158°F)

10. Warranty and Support

Eliwell products are manufactured to high-quality standards and are typically covered by a limited warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Eliwell website.

For technical support, troubleshooting assistance beyond this manual, or to inquire about spare parts, please contact your authorized Eliwell distributor or customer service. When contacting support, please have your product model (IDPlus 902) and any relevant purchase information ready.

Eliwell Official Website: www.eliwell.com

Related Documents - 902

Preview Eliwell IDPlus Electronic Controllers for Refrigeration Installers
Eliwell IDPlus series offers a complete range of electronic controllers for refrigeration installers, featuring flexible and simple operation, clear displays, and USB customization. Models include IDPlus 902, 961, 971, 974, and 978 for various cooling and heating applications.
Preview Eliwell ICPlus 915 : Contrôleur Électronique de Température
Manuel technique pour le contrôleur électronique Eliwell ICPlus 915. Découvrez ses caractéristiques, spécifications, options de configuration et guides d'installation pour une régulation de température précise.
Preview Eliwell ID Plus Series Electronic Controllers: User and Installation Manual
Detailed user and installation manual for Eliwell ID Plus series electronic controllers (models 902, 961, 971, 974). Covers features, connections, applications, troubleshooting, and technical data for refrigeration units.
Preview Eliwell AIR User Manual: Configuration, Monitoring, and Cloud Management for Refrigeration Systems
This comprehensive user manual guides users through the Eliwell AIR system, including the EW AIR EDGE gateway, Eliwell AIR APP, and Eliwell AIR Cloud platform. Learn how to configure, monitor, and manage refrigeration systems efficiently and securely.
Preview Eliwell EWHT800LX: Cold and Curing Room Temperature/Humidity Controller - Technical Specification
Comprehensive technical specifications, user guide, and operational details for the Eliwell EWHT800LX controller, designed for cold rooms and curing rooms. Covers installation, electrical connections, parameter settings, climate profiles, and alarm management.
Preview Guide de démarrage rapide Eliwell REXBOX : Installation, Configuration et Dépannage
Guide rapide pour l'installation, la configuration et le dépannage du coffret Eliwell REXBOX. Apprenez à connecter, paramétrer et gérer les alarmes de votre appareil de réfrigération.