1. Product Overview
The Hygiena SystemSURE Plus is an advanced ATP (Adenosine Triphosphate) hygiene monitoring system designed for rapid and accurate assessment of surface and liquid cleanliness. This next-generation system builds upon the success of the SystemSURE II, offering enhanced functionality, new software capabilities, and increased memory to meet diverse operational demands.
Key Features:
- Sensitive Detection: Detects down to 1 femtomole (1 x 10-15 moles) of ATP, ensuring high accuracy in hygiene monitoring.
- Advanced Photodiode Technology: Features an internal solid-state detector that maintains performance stability, unaffected by drops or shakes.
- Compact and Portable: Small, lightweight, and handheld design for ease of use in various environments.
- Extended Battery Life: Powered by 2 x AA batteries, providing several months of uninterrupted operation.
- Easy Maintenance: Removable read chamber design facilitates simple and thorough cleaning.

Figure 1: The Hygiena SystemSURE Plus ATP Monitoring System, a handheld device for hygiene monitoring.
2. Setup
2.1 Unpacking and Inspection
Carefully unpack all components from the packaging. Verify that all items listed in the packing slip are present and undamaged. If any components are missing or damaged, contact Hygiena customer support immediately.
2.2 Battery Installation
- Locate the battery compartment cover on the back of the SystemSURE Plus device.
- Slide the cover open or remove it according to the indicator.
- Insert two (2) AA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Replace the battery compartment cover securely.
2.3 SureTrend Software Installation
The SureTrend software is essential for data management and analysis. Install the software on a compatible computer by following the instructions provided with the software package or by downloading the latest version from the official Hygiena website. Ensure your computer meets the minimum system requirements.
2.4 Initial Power-On
Press and hold the power button (usually marked with a circle or 'P') until the device screen illuminates. The device will perform a self-test. Once complete, the main menu or ready screen will appear.

Figure 2: The SystemSURE Plus device comfortably held in a user's hand, demonstrating its portability.
3. Operating Instructions
3.1 Performing an ATP Test
- Power on the SystemSURE Plus device.
- Select the desired test plan or location using the navigation buttons.
- Take a Hygiena ATP test swab (e.g., UltraSnap, AquaSnap) and follow its specific instructions for collecting a sample from the surface or liquid to be tested.
- Activate the swab by breaking the Snap-Valve and squeezing the liquid down the swab shaft. Shake gently.
- Insert the activated swab into the SystemSURE Plus read chamber. Ensure it is fully seated.
- Close the chamber lid and press the 'OK' button to initiate the test.
- The device will display the RLU (Relative Light Unit) reading after a 15-second countdown.
3.2 Interpreting Results
The RLU value indicates the level of ATP detected. Higher RLU values correspond to higher levels of biological contamination. Refer to your organization's established pass/fail limits for ATP readings to determine the cleanliness status of the tested area.
3.3 Data Transfer to SureTrend
Connect the SystemSURE Plus device to your computer using the provided USB cable. Open the SureTrend software. Follow the software prompts to synchronize data from the device to the computer for detailed analysis, trending, and reporting.
4. Maintenance
4.1 Cleaning the Device
Regular cleaning ensures optimal performance and longevity of your SystemSURE Plus. Use a soft, damp cloth with a mild, non-abrasive cleaner to wipe the exterior of the device. Avoid harsh chemicals or solvents.
4.2 Cleaning the Read Chamber
The SystemSURE Plus features a removable read chamber for easy cleaning. To clean:
- Ensure the device is powered off.
- Carefully remove the read chamber according to the device's design (refer to the diagram in the full manual if needed).
- Clean the chamber using a lint-free cloth and isopropyl alcohol. Ensure no debris or liquid remains.
- Allow the chamber to dry completely before reinserting it into the device.
4.3 Battery Replacement
When the low battery indicator appears on the screen, replace both AA batteries promptly to avoid interruption of operation and potential data loss. Refer to section 2.2 for battery installation instructions.
4.4 Storage
Store the SystemSURE Plus in a clean, dry environment at room temperature. Avoid extreme temperatures, humidity, and direct sunlight. If storing for extended periods, remove the batteries.

Figure 3: The SystemSURE Plus device resting on its stand, suitable for storage or charging (if applicable).
5. Troubleshooting
5.1 Device Not Powering On
- Check battery installation and ensure correct polarity.
- Replace with fresh AA batteries.
- Ensure the power button is pressed and held sufficiently.
5.2 Inaccurate or Inconsistent Readings
- Verify that ATP test swabs are not expired and have been stored correctly.
- Ensure the read chamber is clean and free of debris (refer to section 4.2).
- Confirm proper sample collection and swab activation techniques.
- Perform a calibration check if available (refer to the full SureTrend manual for calibration procedures).
5.3 SureTrend Software Connection Issues
- Ensure the USB cable is securely connected to both the device and the computer.
- Verify that the SureTrend software is running and updated to the latest version.
- Check your computer's device manager for proper recognition of the SystemSURE Plus.
- Restart both the device and the computer.
For persistent issues, contact Hygiena customer support.
6. Specifications
| Brand Name | Hygiena |
| Model Number | SS3 |
| Item Dimensions (L x W x H) | 7.01 x 1.18 x 2.99 inches |
| Item Weight | 9.12 ounces |
| Power Source | 2 x AA batteries |
| ATP Detection Sensitivity | 1 femtomole (1 x 10-15 moles) |
| Manufacturer | Hygiena |
7. Warranty Information
The Hygiena SystemSURE Plus ATP Monitoring System is covered by a manufacturer's warranty. Specific warranty terms and conditions, including duration and coverage details, are provided with your product documentation. Please retain your proof of purchase for warranty claims. For detailed warranty information, refer to the official Hygiena website or contact customer support.
8. Support
For technical assistance, product inquiries, or to order accessories and consumables, please contact Hygiena customer support. You can find contact information and additional resources, including FAQs and software updates, on the official Hygiena Store on Amazon or the main Hygiena corporate website.