1. Important Safety Information

Read all instructions before installing or using this heater. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury. Keep this manual for future reference.

  • Electrical Connection: This unit requires a 240V, 5000W electrical supply. Installation must be performed by a qualified electrician in accordance with all local and national electrical codes.
  • Overheating Protection: The heater is equipped with an automatic safety shut-off to prevent overheating. If the heater shuts off unexpectedly, allow it to cool down before attempting to restart.
  • Clearance: Maintain adequate clearance from combustible materials. Refer to installation diagrams for minimum distances.
  • Thermostat: A wall thermostat (not included) is required for operation. The use of an electronic thermostat is strongly recommended for optimal performance and energy efficiency.
  • Do Not Cover: Never cover the heater or block its air inlets/outlets. This can cause overheating and fire.
  • Moisture: Do not install the heater in areas where it may be exposed to water or excessive moisture.

2. Product Overview

The StelPro ARUH5CHAR is a 5000W, 240V commercial and residential unit heater designed for spaces up to 500 square feet, such as garages, workshops, and small commercial areas. It features a robust steel construction, adjustable louvers, and a quiet helicoidal fan for efficient heat distribution.

Diagram showing internal components of the StelPro unit heater, including louvers, heating element, fan blade, and motor.

Figure 2.1: Internal components of the unit heater. This diagram illustrates the placement of the louvers, heating element, fan blade, and motor within the unit.

Key Components:

  • Heating Element: Converts electrical energy into heat.
  • Fan Blade: Circulates air over the heating element and into the room.
  • Motor: Powers the fan blade. It is enclosed and permanently lubricated, requiring no maintenance.
  • Louvers: Adjustable fins that direct the airflow and heat.
  • Mounting Bracket: Included for wall or ceiling installation.
Close-up view of the StelPro unit heater's grille and heating elements.

Figure 2.2: Close-up of the heater's grille, showing the protective mesh and internal heating elements.

3. Setup and Installation

Proper installation is critical for safe and efficient operation. It is highly recommended that a qualified electrician perform the electrical wiring.

3.1 Mounting the Heater

The unit heater can be mounted on a wall or ceiling using the included support bracket. Ensure the mounting surface is structurally sound to support the heater's weight (approximately 22 pounds) and any associated wiring.

StelPro unit heater mounted on a wall in a garage or workshop setting.

Figure 3.1: Example of the unit heater mounted on a wall in a typical workshop environment.

Mounting Steps:

  1. Select a suitable location, ensuring adequate clearance from walls, ceilings, and combustible materials as specified in local codes and the provided diagrams.
  2. Securely attach the support bracket to the chosen mounting surface using appropriate fasteners (not included).
  3. Mount the heater onto the support bracket. Ensure it is firmly attached and level.

3.2 Electrical Connection

This heater requires a dedicated 240V circuit with a minimum 20 Amp breaker. It does not come with a power cord or plug. All wiring must comply with national and local electrical codes.

  • Turn off power at the main electrical panel before beginning any wiring.
  • Connect the heater to the 240V power supply.
  • Install an external wall thermostat (not included) according to its manufacturer's instructions and local electrical codes. The heater will not operate without a thermostat.
  • Ensure all connections are secure and properly insulated.
  • After wiring is complete, restore power and test the unit.

3.3 Dimensions and Clearances

Refer to the following diagrams for detailed product dimensions and recommended minimum clearances for safe installation.

Side view dimension diagram of the StelPro unit heater, showing height and depth.

Figure 3.2: Side view dimensions (in inches and millimeters).

Top view dimension diagram of the StelPro unit heater, showing width and mounting points.

Figure 3.3: Top view dimensions (in inches and millimeters).

Front view dimension diagram of the StelPro unit heater, showing width and height.

Figure 3.4: Front view dimensions (in inches and millimeters).

4. Operating Instructions

Once properly installed and wired to a thermostat, operating the StelPro unit heater is straightforward.

4.1 Initial Startup

  1. Ensure all electrical connections are secure and power is supplied to the unit.
  2. Set your external wall thermostat to the desired temperature. The heater will activate when the ambient temperature falls below the set point.
  3. During the first few minutes of operation, a slight odor may be noticeable as manufacturing residues burn off. This is normal and will dissipate quickly.

4.2 Adjusting Louvers

The heater is equipped with adjustable louvers to direct the heated air. Gently adjust the louvers to guide the airflow towards the area requiring heat. Avoid blocking the louvers completely.

4.3 Thermostat Operation

The heater's operation is controlled by the external wall thermostat. Refer to your thermostat's instruction manual for specific settings and programming. For optimal comfort and energy savings, set the thermostat to a comfortable temperature and avoid frequent adjustments.

5. Maintenance

The StelPro unit heater is designed for minimal maintenance. Regular cleaning will ensure efficient operation and prolong the life of the unit.

5.1 Cleaning

  • Before Cleaning: Always disconnect power to the heater at the main electrical panel before performing any cleaning or maintenance.
  • Exterior: Wipe the exterior surfaces with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Interior (Fan/Elements): Periodically, use a vacuum cleaner with a brush attachment to remove dust and debris from the fan blades and heating elements. Ensure the unit is completely cool before cleaning.

5.2 Motor Lubrication

The heater's motor is enclosed and permanently lubricated. No additional lubrication is required.

6. Troubleshooting

If your heater is not operating correctly, consult the following troubleshooting guide. For electrical issues, always contact a qualified electrician.

ProblemPossible CauseSolution
Heater does not turn on.No power supply.
Thermostat set too low.
Safety shut-off activated.
Check circuit breaker.
Increase thermostat setting.
Allow unit to cool, then reset power.
Heater produces insufficient heat.Room size too large for heater.
Thermostat set too low.
Louvers blocked or misdirected.
Ensure heater is appropriate for space.
Increase thermostat setting.
Adjust louvers and clear obstructions.
Fan runs, but no heat.Heating element failure.
Electrical wiring issue.
Contact a qualified electrician or service technician.
Unusual noise from unit.Debris in fan.
Loose mounting.
Disconnect power and inspect fan for debris. Tighten mounting hardware.

7. Specifications

FeatureDetail
Model NumberRUH5
Power Output5000 Watts
Voltage240 Volts
Amperage20 Amps
Heating CoverageUp to 500 square feet
Fan TypeHelicoidal
Airflow (CFM)350 CFM
Mounting TypeWall Mount, Ceiling Mount
Product Dimensions16 x 16 x 16 inches (approximate)
Item Weight22 pounds
Fuel TypeElectric
Special FeatureNoiseless operation

8. Warranty and Support

8.1 Warranty Information

StelPro products are manufactured to high-quality standards. For specific warranty details, including coverage period and terms, please refer to the warranty card included with your product or visit the official StelPro website. Keep your proof of purchase for warranty claims.

8.2 Customer Support

If you have questions about installation, operation, maintenance, or require technical assistance, please contact StelPro customer support. Contact information can typically be found on the manufacturer's website or on the product packaging.

© 2024 StelPro. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.