Introduction

This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the Henny Penny Auto Reset Timer, Model 16602. This genuine OEM replacement part is designed for reliable performance in foodservice applications, featuring 120 Volts and a 20-minute timing capability. Please read this manual thoroughly before using the timer to ensure proper function and safety.

Product Overview

Image of the Henny Penny Auto Reset Timer showing the dial, toggle switch, and reset button.

Figure 1: Henny Penny Auto Reset Timer, Model 16602. This image displays the Henny Penny Auto Reset Timer, highlighting its main components: the central timing dial with minute markings, the 'OFF/TIMER' toggle switch at the bottom left, and the red reset button on the bottom right. The rear mechanism with wiring connections is also visible.

Setup and Installation

Installation of the Henny Penny Auto Reset Timer should only be performed by qualified personnel in accordance with all local and national electrical codes. Ensure power is disconnected before beginning any installation work.

  1. Power Disconnection: Before starting, ensure the main power supply to the equipment where the timer will be installed is completely disconnected and locked out.
  2. Mounting: Securely mount the timer in the designated location within the equipment. Ensure it is stable and free from excessive vibration.
  3. Wiring: Connect the timer according to the equipment's wiring diagram. This timer operates on 120 Volts. Verify all connections are secure and properly insulated. Refer to the specific equipment's service manual for detailed wiring schematics.
  4. Verification: After wiring, double-check all connections for correctness and tightness.
  5. Power Restoration: Once installation is complete and verified, restore power to the equipment.

Operating Instructions

The Henny Penny Auto Reset Timer is designed for straightforward operation. Follow these steps to utilize its timing functions:

  1. Power On: Ensure the equipment connected to the timer is powered on.
  2. Set Timer: Rotate the central dial clockwise to the desired time setting, up to 20 minutes. The timer will automatically start counting down once the dial is released.
  3. Activate Function: Flip the toggle switch from 'OFF' to 'TIMER' to engage the timer function. The timer will begin its countdown.
  4. Completion: Once the set time has elapsed, the timer will automatically reset, and the connected function will typically cease or signal completion.
  5. Manual Reset: If you need to stop the timer before it completes its cycle, press the red reset button. This will immediately stop the countdown and reset the timer.

Maintenance

Regular maintenance ensures the longevity and reliable operation of your Henny Penny Auto Reset Timer. Always disconnect power before performing any maintenance.

  • Cleaning: Periodically wipe the exterior of the timer with a clean, damp cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the timer mechanism.
  • Inspection: Regularly inspect the timer for any signs of physical damage, loose connections, or wear. Pay attention to the dial, switch, and reset button for proper function.
  • Professional Service: For internal repairs or complex issues, contact a qualified service technician. Do not attempt to disassemble the timer yourself.

Troubleshooting

This section provides solutions to common issues you might encounter with your Henny Penny Auto Reset Timer. If the problem persists, contact customer support.

ProblemPossible Solution
Timer does not start.
  • Ensure the equipment is powered on.
  • Verify the toggle switch is in the 'TIMER' position.
  • Check electrical connections for looseness or damage.
  • Confirm the dial has been rotated past the '0' mark.
Timer does not reset automatically.
  • Ensure the timer is fully completing its cycle.
  • Inspect the internal mechanism for obstructions (professional service recommended).
Timer is inaccurate.
  • Verify the power supply voltage is stable at 120 Volts.
  • Ensure the timer is not exposed to extreme temperatures or vibrations.
  • Consider professional calibration or replacement if consistently inaccurate.

Specifications

  • Model Number: 16602
  • Part Number: HEN16602
  • Brand: Henny Penny
  • Voltage: 120 Volts
  • Timer Duration: 20 Minutes
  • Color: Black
  • Item Weight: 2.2 Pounds
  • Product Dimensions: 7 x 7 x 5 inches
  • UPC: 204213730420
  • Number of Settings: 1

Warranty Information

This Henny Penny Auto Reset Timer is a genuine OEM replacement part and is typically covered by the manufacturer's standard warranty against defects in materials and workmanship. Specific warranty terms and duration may vary. Please retain your proof of purchase. For detailed warranty information, it is recommended to contact Henny Penny directly or the authorized distributor from whom the product was purchased.

Customer Support

For technical assistance, replacement parts, or further inquiries regarding your Henny Penny Auto Reset Timer, please contact your authorized Henny Penny dealer or the manufacturer's customer service department. When contacting support, please have your product model number (16602) and serial number (if applicable) ready.

© 2024 Henny Penny. All rights reserved.

This manual is for informational purposes only. Specifications are subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.