Lascar Electronics EL-USB-2-LCD

Lascar EL-USB-2-LCD Temperature and Humidity Data Logger User Manual

Model: EL-USB-2-LCD | Brand: Lascar Electronics

1. Introduction

The Lascar EL-USB-2-LCD is a versatile USB data logger designed to measure and record both temperature and humidity. It features an internal sensor and an integrated LCD display for real-time readings. This manual provides essential information for setting up, operating, and maintaining your data logger.

With its robust design and user-friendly software, the EL-USB-2-LCD is ideal for a wide range of applications requiring accurate environmental monitoring.

2. Key Features

  • LCD Display: Shows current ambient temperature and humidity readings.
  • Measurement Range: -35°C to 80°C for temperature and 0 to 100% RH for humidity.
  • Accuracy: 0.5°C for temperature and 3.0% RH for humidity.
  • Sampling Rate: User-configurable from 10 seconds to 12 hours.
  • Storage Capacity: Stores up to 16,000 samples.
  • Battery Life: Approximately 1 year with a user-replaceable 1/2 AA 3.6 Volt Lithium Battery.
  • Indicators: LED operational and alarm indicators.
  • Durability: IP67 Rating for protection against dust and water immersion.
  • Connectivity: Direct USB connection for setup, data download, and analysis.
  • Software: PC-compatible software available as a free download, supporting Windows 10, 8, 7, Vista, and XP (32-bit and 64-bit versions).

3. Package Contents

Upon unpacking your EL-USB-2-LCD data logger, please ensure all the following items are present:

  • Lascar EL-USB-2-LCD Temperature and Humidity Data Logger
  • Protective USB Cap
  • Mounting Bracket (if included with your specific package)
  • 1/2 AA 3.6 Volt Lithium Battery (pre-installed or separate)
  • Quick Start Guide (this manual provides comprehensive details)
Lascar EL-USB-2-LCD data logger with mounting bracket and battery

Figure 3.1: EL-USB-2-LCD Data Logger with included accessories (mounting bracket and battery).

4. Setup and Software Installation

To begin using your EL-USB-2-LCD data logger, you will need to install the Lascar EasyLog software on your computer.

  1. Download Software: Visit the official Lascar Electronics website (refer to the product page or support section) to download the latest version of the EasyLog software. The software is compatible with Windows 10, 8, 7, Vista, and XP (both 32-bit and 64-bit versions).
  2. Install Software: Run the downloaded installer and follow the on-screen prompts to complete the software installation.
  3. Connect Logger: Remove the protective cap from the USB connector of the data logger. Plug the logger directly into an available USB port on your computer.
  4. Initial Configuration: Launch the EasyLog software. The software will automatically detect the connected logger. From here, you can configure various settings such as:
    • Logger Name
    • Sampling Rate (e.g., every 10 seconds, 1 hour, etc.)
    • Start Mode (e.g., immediate, push-button, delayed start)
    • Alarm Thresholds (high/low temperature and humidity)
    • Measurement Units (°C/°F)
  5. Start Logging: Once configured, disconnect the logger from the computer. Depending on your chosen start mode, the logger will begin recording data.
Lascar EL-USB-2-LCD data logger showing LCD display with humidity reading

Figure 4.1: EL-USB-2-LCD Data Logger with its integrated LCD display.

5. Operating Instructions

5.1 Reading the LCD Display

The EL-USB-2-LCD features a clear LCD display that shows the current temperature and humidity readings. The display cycles between temperature (°C or °F) and relative humidity (%RH) at regular intervals. Alarm indicators (if configured) may also appear on the display.

5.2 Data Logging

Once configured and started, the logger will automatically record data at the specified sampling rate. The LED indicators will provide visual feedback on the logger's status (e.g., green for normal operation, red for alarms).

5.3 Downloading Data

To download recorded data:

  1. Plug the EL-USB-2-LCD data logger back into your computer's USB port.
  2. Open the EasyLog software.
  3. The software will automatically detect the logger and prompt you to download the data.
  4. Once downloaded, you can view the data in graphical or tabular format, export it to various file types (e.g., CSV, Excel), and generate reports.

5.4 Stopping a Logging Session

A logging session can be stopped via the EasyLog software when the device is connected to the computer, or if configured, by pressing a button on the device itself (if applicable to your model's settings).

6. Maintenance

6.1 Battery Replacement

The EL-USB-2-LCD uses a user-replaceable 1/2 AA 3.6 Volt Lithium Battery. The typical battery life is approximately one year, depending on usage and sampling rate. When the battery is low, the logger's LED may indicate this, and the software will also notify you.

To replace the battery:

  1. Ensure the logger is not actively recording data and is disconnected from the computer.
  2. Carefully open the battery compartment (refer to the device's physical design for access).
  3. Remove the old battery and insert a new 1/2 AA 3.6 Volt Lithium Battery, observing correct polarity.
  4. Securely close the battery compartment.

Warning:

  • Use only the specified battery type.
  • Dispose of old batteries responsibly according to local regulations.

6.2 Cleaning

Wipe the logger with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the USB port and sensor areas are kept clean and free of debris.

7. Troubleshooting

Problem Possible Cause Solution
Logger not detected by software. Software not installed correctly; USB connection issue; Driver issue. Ensure EasyLog software is installed. Try a different USB port. Restart computer. Reinstall software.
Inaccurate readings. Sensor obstruction; Environmental interference; Calibration needed. Ensure sensor area is clear. Avoid placing logger near heat sources/vents. Consult Lascar support for calibration information.
Logger not recording data. Not configured to start; Battery low/dead; Memory full. Check configuration in EasyLog software. Replace battery. Download data and clear logger memory.
LCD display is blank. Battery dead; Logger in sleep mode. Replace battery. Connect to PC to check status.

8. Specifications

Parameter Value
Model NumberEL-USB-2-LCD
Measurement Range (Temperature)-35°C to 80°C (-31°F to 176°F)
Measurement Range (Humidity)0 to 100% RH
Accuracy (Temperature)±0.5°C (±0.9°F) typical
Accuracy (Humidity)±3.0% RH typical
Logging RateUser-configurable from 10 seconds to 12 hours
Memory Capacity16,000 readings (8,000 temperature, 8,000 humidity)
Battery Type1/2 AA 3.6V Lithium (included)
Battery LifeApproximately 1 year
Dimensions0.98"W x 3.9"H (0.98 x 0.98 x 3.9 inches)
Weight2.4 ounces
IP RatingIP67
ConnectivityUSB
Software CompatibilityWindows 10, 8, 7, Vista, XP (32-bit & 64-bit)

9. Warranty and Support

Lascar Electronics products are manufactured to high standards and are typically covered by a limited warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Lascar Electronics website.

For technical support, software downloads, or further assistance, please contact Lascar Electronics customer service or visit their online support portal. Ensure you have your product model number (EL-USB-2-LCD) and any relevant purchase information ready when seeking support.

Manufacturer: Lascar Electronics

Related Documents - EL-USB-2-LCD

Preview EasyLog EL-USB Data Logger Quick Start Guide | Lascar Electronics
A quick start guide for the Lascar Electronics EasyLog EL-USB series of data loggers, covering software installation, usage, battery replacement, and an overview of the EasyLog product range.
Preview Lascar EL-USB-1-PRO Installation and Operation Guide
Comprehensive guide for installing, operating, and troubleshooting the Lascar EL-USB-1-PRO temperature data logger. Includes setup, software installation, and environmental disposal information.
Preview EL-USB-TC Thermocouple Data Logger with USB Interface - Lascar Electronics
Detailed overview of the Lascar EL-USB-TC thermocouple data logger, featuring temperature measurement ranges for J, K, and T types, USB interface, programmable alarms, and LED status indicators. Includes specifications, software details, and product range comparison.
Preview Lascar EL-IOT Wireless Cloud-Connected Data Logger Quick Start Guide
Get started quickly with the Lascar EL-IOT wireless data logger. This guide covers device setup, indicators, safety, and button functions for cloud-connected data logging.
Preview EL-USB-2: Temperature, Humidity, and Dew Point Data Logger by Lascar Electronics
Discover the Lascar EL-USB-2, a versatile data logger designed for accurate measurement and recording of temperature, humidity, and dew point. This IP67-rated device features a large data storage capacity, user-configurable logging rates, and is supported by the free EasyLog software for data analysis and reporting.
Preview EL-USB-2 Humidity, Temperature, and Dew Point USB Data Logger | Lascar Electronics
Detailed overview of the Lascar Electronics EL-USB-2 USB data logger, featuring humidity, temperature, and dew point measurement capabilities. Includes specifications, features, ordering information, and software details for environmental monitoring.