Honeywell D06F-1E

Honeywell Braukmann D06F-1E Pressure Reducer

Instruction Manual

1. Introduction

The Honeywell D06F pressure reducer is designed to protect domestic water systems from excessive supply pressure. It is also suitable for various industrial and commercial applications, provided its specifications are met. The use of a pressure reducer helps prevent pressure-related damage and can contribute to reduced water consumption. This device ensures that the set outlet pressure remains constant, even when inlet pressures fluctuate significantly. By reducing and stabilizing the operating pressure, disruptive flow noises within the installation are minimized.

Honeywell Braukmann D06F-1E Pressure Reducer

Image showing the Honeywell Braukmann D06F-1E pressure reducer, highlighting its brass body and adjustment knob.

2. Product Features and Components

The D06F-1E pressure reducer incorporates several key features and high-quality components:

3. Application Area

This pressure reducer is suitable for use with:

The maximum operating temperature for these media is 40 °C.

4. Setup and Installation

Proper installation is crucial for the optimal performance and longevity of the pressure reducer. It is recommended that installation be performed by a qualified professional.

  1. System Depressurization: Ensure the water supply system is completely depressurized and drained before beginning installation.
  2. Installation Location: Install the pressure reducer in the main water line, typically after the water meter and any primary filter. Ensure it is easily accessible for future maintenance.
  3. Flow Direction: Observe the flow direction arrow marked on the reducer's housing. The device must be installed in the correct flow orientation.
  4. Connections: For the D06F-1E variant, which comes without connection screw fittings, ensure appropriate and properly sealed pipe connections are made to the 1-inch external thread. Use suitable sealing materials (e.g., PTFE tape or hemp with sealing paste).
  5. Space Requirements: Allow sufficient space around the unit for future adjustments, maintenance, and potential replacement of components.
  6. Leak Check: After installation, slowly repressurize the system and carefully check all connections for leaks.

5. Operating and Pressure Adjustment

The Honeywell D06F-1E pressure reducer is designed for straightforward pressure adjustment.

  1. Factory Preset: The unit is typically factory preset to an outlet pressure of 3 bar.
  2. Adjustment Range: The outlet pressure can be adjusted within a range of 1.5 to 6 bar.
  3. Adjustment Procedure: To change the outlet pressure, turn the adjustable handle. Turning clockwise generally increases pressure, while turning counter-clockwise decreases it.
  4. Pressure Verification: While an adjustment scale is present, it is highly recommended to connect an external manometer (pressure gauge) to the G 1/4" port to accurately verify the set outlet pressure. This ensures precise control and compensates for any potential inaccuracies of the integrated scale.
  5. Minimum Pressure Difference: For the pressure reducer to function correctly, there must be a minimum pressure difference of 1 bar between the inlet (upstream) and outlet (downstream) pressures.

6. Maintenance

Regular maintenance ensures the continued efficiency and reliability of your pressure reducer.

7. Troubleshooting

If you encounter issues with your Honeywell D06F-1E pressure reducer, consider the following troubleshooting steps:

If these steps do not resolve the issue, contact a qualified plumbing professional or Honeywell customer support.

8. Specifications

ParameterValue
KVS-value5.8 m³/h
Construction Length180 mm
Inlet Pressure (Pre-pressure)Max. 16 bar
Outlet Pressure (Back-pressure)1.5 to 6 bar (preset to 3 bar)
Minimum Pressure Difference1 bar
Fine Strainer Mesh SizeApprox. 0.16 mm
Maximum Operating Temperature40 °C
Connection Size1 inch AG (External Thread)
Nominal WidthDN25
Connection TypeWithout connection screw fittings (Variant E)
MaterialDezincification-resistant brass housing, plastic components
CertificationsWRAS, DVGW (Component tested in connection sizes G 1/2" to 2", Sound insulation tested in R 1/2" to R 1 1/4" - Group 1)
Manufacturer Part NumberD06F-1"E
Model Number ItemD06FGE23
First AvailabilityJanuary 15, 2020

9. Warranty and Support

Specific warranty information and detailed customer support contacts are not provided within the available product data. For comprehensive warranty details, technical assistance, or to locate authorized service providers, please refer to the official Honeywell website or contact your original retailer.