1. Product Overview
The Belden 8723 060500 is a high-quality, shielded multi-pair cable designed for various industrial and commercial applications requiring reliable signal transmission. This cable features two twisted pairs, each individually shielded, and an overall shield to provide superior protection against electromagnetic interference (EMI) and radio frequency interference (RFI). It is rated for 300V and comes in a 500-foot length, suitable for both indoor and outdoor installations.
Key features include:
- Construction: 2 twisted pairs, each with individual foil shield.
- Overall Shield: Tinned copper braid for enhanced EMI/RFI protection.
- Voltage Rating: 300V.
- Length: 500 feet (152.4 meters).
- Jacket: Chrome (CHR) colored jacket.
- Usage: Suitable for both indoor and outdoor environments.

Figure 1: Internal structure of Belden 8723 060500 cable, highlighting the shielded pairs and overall shielding for noise reduction.
2. Safety Information
Always adhere to local electrical codes and safety regulations when installing or working with electrical cables. Failure to do so can result in serious injury or damage to equipment.
- Ensure power is disconnected before handling or installing the cable.
- Wear appropriate personal protective equipment (PPE), including safety glasses and gloves.
- Do not exceed the cable's specified voltage rating of 300V.
- Avoid sharp bends or excessive pulling force that could damage the cable's insulation or shielding.
- Properly ground all shielding as per industry standards to ensure effective EMI/RFI protection and safety.
- Consult a qualified electrician for complex installations or if you are unsure about any procedure.
3. Setup and Installation
Proper installation is crucial for the optimal performance and longevity of your Belden 8723 060500 cable.
- Planning the Route: Carefully plan the cable route, considering environmental factors, potential interference sources, and physical protection. Ensure the cable length is sufficient without excessive slack or tension.
- Cable Preparation: Cut the cable to the desired length using appropriate cable cutters. Carefully strip the outer jacket, individual pair shields, and insulation without damaging the conductors.
- Termination: Terminate the conductors to connectors or terminal blocks according to the equipment manufacturer's specifications. Ensure secure and clean connections. For shielded cables, proper termination of the shield is critical.
- Shield Grounding: Connect the overall shield and individual pair shields (if required by application) to a proper ground point. This is essential for effective noise rejection. Typically, the shield is grounded at one end to prevent ground loops, but specific applications may require grounding at both ends or drain wire connection to a common ground bar. Refer to application-specific guidelines.
- Securing the Cable: Use cable ties, clamps, or conduits to secure the cable along its route, preventing strain, abrasion, and accidental damage. Maintain appropriate bend radii to avoid internal damage.
- Testing: After installation, perform continuity and insulation resistance tests to verify proper connections and ensure there are no shorts or open circuits.

Figure 2: Example of proper shielded cable termination, emphasizing shield grounding.
4. Operating Considerations
Once installed, the Belden 8723 060500 cable is designed for reliable operation. Consider the following for optimal performance:
- Environmental Conditions: While rated for indoor/outdoor use, avoid exposing the cable to extreme temperatures, direct sunlight for prolonged periods without UV protection, or harsh chemicals that could degrade the jacket.
- Load Management: Ensure the current and voltage loads do not exceed the cable's specifications (300V). Overloading can lead to overheating and damage.
- Interference: Although shielded, routing the cable away from high-power electrical lines, motors, or other strong EMI/RFI sources can further enhance signal integrity.
- Physical Protection: Protect the cable from physical damage, such as crushing, cutting, or abrasion, especially in high-traffic areas.
5. Maintenance
The Belden 8723 060500 cable requires minimal maintenance, but periodic inspection can help ensure continued performance and safety.
- Visual Inspection: Periodically inspect the cable jacket for any signs of physical damage, cracks, or discoloration. Check terminations for corrosion or loose connections.
- Cleaning: If necessary, clean the cable jacket with a soft, damp cloth. Avoid using harsh solvents or abrasive cleaners.
- Re-testing: In critical applications or after any significant system changes, consider re-testing cable continuity and insulation resistance.
- Environmental Review: Ensure the cable remains protected from environmental stressors that may have changed since installation.
6. Troubleshooting
This section addresses common issues that may arise with cable installations.
| Problem | Possible Cause | Solution |
|---|---|---|
| Signal Loss or Degradation | Damaged cable, improper termination, excessive cable length, high interference. | Inspect cable for damage. Re-terminate connections. Verify cable length is within specifications. Check for and mitigate interference sources. |
| Intermittent Connection | Loose connections, minor cable damage, environmental factors (e.g., temperature fluctuations). | Tighten all connections. Inspect cable for subtle damage. Ensure environmental conditions are within operating limits. |
| Excessive Noise/Interference | Improper shield grounding, proximity to strong EMI/RFI sources, damaged shield. | Verify shield is properly grounded. Re-route cable away from noise sources. Inspect shield for damage. |
| Cable Overheating | Overcurrent, insufficient ventilation, damaged insulation. | Reduce current load to within cable specifications. Ensure adequate airflow around the cable. Inspect for insulation damage. |
7. Specifications
Detailed technical specifications for the Belden 8723 060500 cable.
| Brand | Belden |
| Model Number | 8723 060500 |
| Cable Type | Shielded Multi-Pair Cable |
| Number of Pairs | 2 Pairs |
| Length | 500 feet (152.4 meters) |
| Voltage Rating | 300V |
| Shielding | Individual foil shields per pair, overall tinned copper braid shield |
| Jacket Color | Chrome (CHR) |
| Indoor/Outdoor Usage | Indoor, Outdoor |
| Specification Met | CSA |
| ASIN | B00HEX814S |
| UPC | 013227064113 |
8. Warranty and Support
For specific warranty information and technical support regarding your Belden 8723 060500 cable, please refer to the official Belden website or contact Belden customer service directly. Keep your purchase receipt as proof of purchase.
Belden Official Website: www.belden.com
Contact Information: Refer to the "Contact Us" section on the official website for regional support details.