Myers HR50D
Pentair Myers 1/2 hp 11.5 gph Cast Iron Convertible Jet Pump - Model HR50D
User Instruction Manual
1. Introduction
This manual provides detailed instructions for the safe and efficient operation of your Pentair Myers Convertible Jet Pump. This heavy-duty pump features a machined durable cast iron body, precision-molded impellers, and a high-quality adjustable pressure switch. It is designed for reliable performance in various water pumping applications. Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage or injury.

Image 1.1: The Pentair Myers 1/2 hp 11.5 gph Cast Iron Convertible Jet Pump. This image shows the pump's green cast iron body, the motor housing, and the inlet/outlet ports on the front. A small metal tag with 'Myers' is visible on the side of the pump head.
2. Safety Information
Always observe the following safety precautions to reduce the risk of injury, electric shock, or fire:
- Electrical Safety: Ensure the pump is properly grounded. Do not operate the pump with a damaged cord or plug. Disconnect power before servicing.
- Water Safety: Do not use this pump for flammable or corrosive liquids. Ensure proper ventilation to prevent condensation.
- Installation: All electrical wiring and plumbing should be performed by qualified personnel in accordance with local codes and regulations.
- Operation: Do not run the pump dry. Always ensure the pump is primed before starting.
- Maintenance: Wear appropriate personal protective equipment (PPE) during maintenance.
3. Setup
Follow these steps for initial setup and installation:
- Mounting: Securely mount the pump on a stable, level surface using appropriate fasteners. Ensure adequate space around the pump for ventilation and maintenance.
- Plumbing Connections: Connect the suction and discharge lines to the pump. Use thread sealant on all pipe connections to prevent leaks. Ensure all connections are tight but do not overtighten.
- Priming: Before initial startup, remove the priming plug and fill the pump casing with water until it overflows. Replace the priming plug securely.
- Electrical Connection: Connect the pump to a dedicated electrical circuit with the correct voltage (as specified on the pump's nameplate). Ensure proper grounding.
- Pressure Switch Adjustment: The pump comes with a pre-set pressure switch. Adjustments should only be made by a qualified technician if necessary, following the instructions provided with the pressure switch.
4. Operating Instructions
Once installed and primed, the pump is ready for operation:
- Initial Start-up: Turn on the power supply to the pump. The pump should start and begin to build pressure.
- Monitoring: Observe the pressure gauge to ensure the pump is operating within its specified pressure range. Listen for unusual noises or vibrations.
- Automatic Operation: The pump's pressure switch will automatically turn the pump on and off based on system demand and pressure settings.
- Shut-down: To turn off the pump, simply turn off the power supply. For extended periods of non-use, drain the pump to prevent freezing or corrosion.
5. Maintenance
Regular maintenance ensures the longevity and efficient operation of your pump:
- Periodic Inspection: Regularly inspect the pump for leaks, corrosion, or damage to the casing, motor, and electrical connections.
- Cleanliness: Keep the pump and surrounding area clean and free of debris to ensure proper ventilation.
- Pressure Switch Check: Periodically verify that the pressure switch is functioning correctly and maintaining the desired pressure range.
- Winterization: In cold climates, drain the pump and associated piping completely to prevent damage from freezing.
- Seal Replacement: If water leaks from the shaft seal, it may need replacement. This should be performed by a qualified technician.
6. Troubleshooting
Refer to the following table for common issues and their solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; tripped breaker; faulty motor. | Check power supply; reset breaker; consult technician. |
| Pump runs but no water | Pump not primed; air leak in suction line; low water level. | Re-prime pump; check suction line for leaks; ensure adequate water supply. |
| Low pressure/flow | Clogged impeller; worn parts; incorrect pressure switch setting. | Clean impeller; inspect for wear; adjust pressure switch. |
| Pump cycles too frequently | Leaking plumbing; waterlogged pressure tank; faulty pressure switch. | Check for leaks; inspect pressure tank; replace pressure switch. |
7. Specifications
Technical specifications for the Pentair Myers HR50D Jet Pump:
| Attribute | Value |
|---|---|
| Brand | Myers |
| Model Number | HR50D |
| Material | Cast Iron (Body), Stainless Steel (Components) |
| Color | Green |
| Power Source | Corded Electric |
| Maximum Flow Rate | 0.48 Gallons Per Minute (GPM) |
| Item Weight | 35.6 pounds |
| Package Dimensions | 20.06 x 11.25 x 8.56 inches |
| UPC | 054128413020 |
8. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact Myers customer service directly. Keep your purchase receipt as proof of purchase for warranty claims.
For further assistance, please visit the official Myers website or contact their authorized service centers.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.