DAB 102662020

DAB Jet 82 MP Electric Pump User Manual

1. Product Overview

The DAB Jet 82 MP is a high-performance, self-priming electric centrifugal pump engineered for reliable water supply in various settings, including domestic systems, small-scale agricultural irrigation, and garden applications. Its self-priming capability ensures efficient operation even when air bubbles are present in the water.

Key components include a durable cast iron pump body and motor bracket, a technopolymer impeller, diffuser, and Venturi tube designed for sand protection. The pump features a robust carbon/ceramic mechanical seal and an asynchronous motor that is enclosed and cooled by external ventilation. The single-phase version includes built-in thermal ammeter protection and a permanently inserted capacitor.

DAB Jet 82 MP Electric Pump, green with black motor and power cord

Figure 1: The DAB Jet 82 MP Electric Pump. This image shows the green pump body, the black motor housing, the pressure gauge, and the power cord with a European plug. The brass fitting for water connection is visible at the top.

2. Safety Information

Always adhere to the following safety guidelines to prevent injury and damage to the pump:

  • Electrical Safety: Ensure the pump is connected to a properly grounded electrical outlet. Do not operate with damaged cords or plugs. Disconnect power before any maintenance or inspection.
  • Water Temperature: Do not pump liquids outside the specified temperature range (0 °C to +35 °C for domestic use, 0 °C to +40 °C for other applications).
  • Liquid Type: Only pump clean, non-viscous, non-aggressive, non-crystallized, and chemically neutral liquids free from solid or abrasive substances.
  • Installation: Install the pump in a well-ventilated area, protected from direct sunlight and freezing temperatures. Ensure stable mounting.
  • Children and Pets: Keep children and pets away from the pump during operation.
  • Professional Installation: For optimal safety and performance, electrical connections and complex installations should be performed by a qualified professional.

3. Setup and Installation

Proper installation is crucial for the pump's longevity and efficient operation.

  1. Location: Choose a dry, well-ventilated location, close to the water source and power supply. The pump should be protected from weather elements and extreme temperatures.
  2. Mounting: Secure the pump to a stable, level surface using appropriate fasteners to minimize vibration and noise.
  3. Pipe Connections: Connect the suction and discharge pipes. Ensure all connections are airtight to prevent air ingress, which can affect priming. Use flexible connectors to reduce vibration transmission.
  4. Priming: Before first use, fill the pump body completely with water through the designated priming port until it overflows. This is essential for self-priming pumps.
  5. Electrical Connection: Connect the pump to a suitable power supply (230 Volts) as per local electrical codes. Ensure the circuit has appropriate overcurrent protection.

4. Operating Instructions

Follow these steps for safe and effective operation of your DAB Jet 82 MP pump:

  1. Initial Start-up: After installation and priming, ensure all valves are open and the discharge line is clear. Plug in the pump or switch on the power supply.
  2. Monitoring: Observe the pump during the first few minutes of operation. It should draw water and build pressure smoothly. Listen for unusual noises.
  3. Continuous Operation: The pump is designed for continuous operation within its specified limits. Avoid running the pump dry, as this can cause severe damage.
  4. Shut-down: To stop the pump, simply disconnect the power supply. If the pump will be out of use for an extended period, follow the maintenance and storage guidelines.

5. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your pump.

  • Routine Checks: Periodically inspect the pump for any signs of leaks, unusual noises, or vibrations. Check electrical connections for tightness and corrosion.
  • Cleaning: Keep the pump exterior clean and free from dust and debris to ensure proper motor cooling.
  • Winterization: If the pump is exposed to freezing temperatures, it must be drained completely to prevent damage from ice expansion. Disconnect pipes and open drain plugs. Store in a dry, frost-free location.
  • Mechanical Seal: The mechanical seal is designed for durability, but if leaks occur around the shaft, it may need replacement by a qualified technician.

6. Troubleshooting

This section addresses common issues you might encounter with your pump.

ProblemPossible CauseSolution
Pump does not startNo power supply; Motor overload protection tripped; Impeller jammed.Check power connection/circuit breaker; Reset thermal protection; Inspect and clear impeller.
Pump runs but no water is deliveredPump not primed; Air leak in suction line; Suction lift too high; Foot valve clogged.Re-prime the pump; Check all suction connections for leaks; Reduce suction lift; Clean foot valve.
Low pressure or flowPartial air leak; Clogged impeller/pipes; Worn impeller; Insufficient power.Check suction line; Clean pump and pipes; Contact service for impeller replacement; Verify power supply.
Excessive noise or vibrationAir in pump/suction line; Unsecured mounting; Bearing wear.Re-prime; Check for air leaks; Secure pump mounting; Contact service for bearing inspection.

If the problem persists after attempting these solutions, please contact qualified service personnel.

7. Technical Specifications

Detailed specifications for the DAB Jet 82 MP Electric Pump:

SpecificationValue
Model Number102662020
BrandDAB
Product Dimensions43 x 30 x 25 cm
Item Weight11.2 Kilograms
ColorBlack, Green
MaterialCast Iron, Technopolymer
StyleCentrifugal Pump
Power SourceCorded Electric
Max. Flow Rate10.5 Cubic meters per hour
Max. Head Height62 Meters
Voltage230 Volts
Liquid Temperature Range0 °C to +35 °C (domestic), 0 °C to +40 °C (other)
Max. Ambient Temperature+40 °C
Max. Operating Pressure6 bar (600 kPa)
Protection ClassIP 44 (IP 55 at terminal board)
Insulation ClassF
ASINB00GWEQVCE
Available on Amazon.de since6. November 2016
Discontinued Item (Production Discontinued by Manufacturer)No

8. Warranty and Support

For information regarding warranty coverage, technical support, or authorized service centers, please refer to the documentation provided with your purchase or visit the official DAB Pumps website. Keep your proof of purchase for warranty claims.

It is recommended to only use genuine DAB replacement parts for any repairs to ensure continued performance and safety.

© 2024 DAB Pumps. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.