Model: MCL006

1. Introduction

This manual provides essential information for the safe and effective use of the Edison MCL-6 MCL006 6 Amp, 600V Midget Fast Blow Fuse. This fuse is designed to protect electrical circuits from overcurrent conditions by melting and breaking the circuit when current exceeds its rated value. Please read this manual thoroughly before installation or replacement.

2. Safety Information

Always observe the following safety precautions when working with electrical components:

  • Disconnect Power: Ensure all power to the circuit is disconnected before installing, inspecting, or replacing fuses. Failure to do so can result in electric shock or injury.
  • Use Correct Rating: Always replace a blown fuse with a fuse of the exact same type, voltage, and amperage rating. Using an incorrect fuse can lead to inadequate protection, circuit damage, or fire.
  • Wear Protective Gear: Use appropriate personal protective equipment (PPE) such as insulated gloves and safety glasses when working with electrical systems.
  • Consult a Professional: If you are unsure about any aspect of fuse installation or electrical work, consult a qualified electrician.

3. Product Overview

The Edison MCL-6 MCL006 is a midget fast blow fuse designed for various electrical applications requiring rapid circuit protection. It features a compact design and is rated for 6 Amps at 600 Volts. This fuse is suitable for use as a direct replacement for Littlefuse KLK006 (KLK-6) and Ferraz Shamwut/Mersen ATM-6 fuses, offering reliable overcurrent protection.

Edison MCL-6 MCL006 6 Amp 600V Midget Fast Blow Fuse

Figure 1: Edison MCL-6 MCL006 6 Amp 600V Midget Fast Blow Fuse. This image displays the cylindrical body of the fuse with metallic end caps and a blue label indicating 'Edison', 'FAST-ACTING FUSE', and 'MCL-6 6 AMP 600V'.

4. Specifications

SpecificationValue
BrandEdison
Model NumberMCL006
AC Adapter Current6 Amps
Voltage Rating600 Volts
Mounting TypeThrough-Hole Mount
Fuse TypeMidget Fast Blow
UPC616469708441

5. Installation

Follow these general steps for installing the Edison MCL-6 MCL006 fuse:

  1. Power Disconnection: Turn off and disconnect all power to the circuit where the fuse will be installed. Verify with a voltage tester that the circuit is de-energized.
  2. Locate Fuse Holder: Identify the fuse holder or block in the electrical panel or device.
  3. Remove Old Fuse (if applicable): If replacing a blown fuse, carefully remove the old fuse from its holder. Use a fuse puller if necessary to avoid direct contact and ensure safety.
  4. Insert New Fuse: Insert the Edison MCL-6 MCL006 fuse into the designated fuse holder. Ensure it is seated firmly and correctly.
  5. Restore Power: Once the fuse is securely in place, restore power to the circuit.

Important: Always ensure the replacement fuse matches the original fuse's specifications (amperage, voltage, and type) to maintain proper circuit protection.

6. Operation

The Edison MCL-6 MCL006 is a passive safety device. It operates by allowing electrical current to flow through a metallic element. If the current flowing through the fuse exceeds its 6 Amp rating for a specified duration, the metallic element will melt, or 'blow', creating an open circuit. This action interrupts the flow of electricity, protecting downstream components and wiring from damage due to overcurrent or short-circuit conditions. As a fast blow fuse, it reacts quickly to overcurrents.

7. Maintenance

Fuses are generally maintenance-free components. However, periodic inspection of the fuse and its holder is recommended:

  • Visual Inspection: Occasionally inspect the fuse for any signs of physical damage or discoloration.
  • Connection Check: Ensure the fuse is securely seated in its holder to maintain good electrical contact.
  • Environmental Conditions: Ensure the fuse is not exposed to excessive moisture, dust, or extreme temperatures beyond its operating limits, which could affect its performance or lifespan.

A blown fuse cannot be repaired and must be replaced.

8. Troubleshooting

If a circuit protected by the Edison MCL-6 MCL006 fuse stops functioning, the fuse may have blown. Follow these steps:

  1. Disconnect Power: Always disconnect power to the circuit before inspecting or replacing the fuse.
  2. Inspect the Fuse: Visually check the fuse. A blown fast blow fuse often shows a broken or melted internal wire. Some fuses may have a clear body allowing visual inspection.
  3. Test for Continuity: If visual inspection is inconclusive, use a multimeter to test for continuity across the fuse. A blown fuse will show an open circuit (no continuity).
  4. Identify Cause: Before replacing a blown fuse, attempt to identify and rectify the cause of the overcurrent (e.g., short circuit, overloaded appliance, faulty wiring). Repeatedly blowing fuses indicates an underlying electrical problem that needs professional attention.
  5. Replace Fuse: Replace the blown fuse with a new Edison MCL-6 MCL006 fuse or an equivalent with the identical amperage and voltage rating. Refer to the Installation section for proper replacement.

9. Compatibility and Replacement

The Edison MCL-6 MCL006 fuse is designed to be a direct substitute for the following models:

  • Littlefuse KLK006 (KLK-6)
  • Ferraz Shamwut/Mersen ATM-6

When replacing any fuse, ensure the new fuse matches the original's specifications for amperage, voltage, and response time (e.g., fast blow, slow blow) to ensure proper circuit protection.

10. Warranty and Support

For information regarding product warranty, technical support, or further assistance, please refer to the official Edison brand website or contact their customer service department. Keep your purchase receipt for warranty claims.

Related Documents - MCL006

Preview Edison 5x20mm Glass Fast-Acting GMA Fuses - Product Information and Specifications
Detailed product information, specifications, and cross-reference guide for Edison 5x20mm Glass Fast-Acting GMA Fuses, including features, applications, agency approvals, and technical data.
Preview Edison Dual Element Time-Delay Class J Fuses - Product Information
Comprehensive product information for Edison Dual Element Time-Delay Class J Fuses, including specifications, features, applications, and cross-reference data. Covers JDL series fuses and related fuse blocks and holders.
Preview Edison Dual Element Time-Delay Class RK1 Fuses - Product Information
Detailed information on Edison Dual Element Time-Delay Class RK1 Fuses, including features, applications, specifications, dimensions, and current limitation data. Covers LENRK and LESRK series.
Preview Edison Fuses Selection Guide: Circuit Protection Solutions by AutomationDirect
Comprehensive guide to Edison fuses, fuse holders, and fuse blocks from AutomationDirect. Learn about applications, benefits, and selection criteria for industrial and commercial circuit protection. Features UL/NEC compliant products.
Preview Edison Circuit Protection Products Catalog | Eaton
Explore the comprehensive Edison circuit protection product catalog from Eaton, featuring a wide range of fuses, fuse blocks, and accessories for industrial and commercial applications. Find detailed specifications, ratings, and cross-references.
Preview Edison Product Catalog: Circuit Protection Products
Explore the comprehensive Edison Product Catalog featuring a wide array of circuit protection solutions. This catalog details various fuse types, including time-delay, fast-acting, high-speed, and specialty fuses, along with their specifications, performance data, and application guidance for industrial and commercial electrical systems.