1. Introduction
Thank you for choosing the Symphony Diet 22i Air Cooler. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your new appliance. Please read it thoroughly before use and retain it for future reference.

Figure 1: Front view of the Symphony Diet 22i Air Cooler, showcasing its sleek design and air throw.
2. Important Safety Instructions
To reduce the risk of fire, electric shock, or injury, always follow these basic safety precautions:
- Ensure the power supply voltage matches the cooler's rating.
- Do not operate the cooler with a damaged cord or plug.
- Always unplug the cooler before cleaning, servicing, or moving it.
- Do not immerse the cooler or its electrical components in water.
- Keep children and pets away from the cooler during operation.
- Place the cooler on a stable, level surface to prevent tipping.
- Ensure adequate cross-ventilation by keeping a window or door open when operating the cooler.
- Do not block air inlets or outlets.
- Use only clean water in the tank.
3. Product Features
The Symphony Diet 22i Air Cooler is designed with several features for enhanced performance and user convenience:
- I-Pure Technology: Multi-stage air purification with 5 filters against dust, smell, allergy, bacteria, and wash.
- Area Capacity: Suitable for rooms up to 150 Sq Ft (42 m³).
- Low Power Consumption: Operates at only 170 W.
- System Restore Function: Remembers and restores previous settings.
- Honeycomb Pad: Absorbs dust particles and provides sanitized airflow.
- Full Function Remote: Includes a remote placing dock for convenient operation.
- Seven Hour Remote Timer: Allows for timed operation.
- Empty Water Tank Alarm: Alerts when water level is low.
- Dura Pump Technology: Ensures greater durability and longer pump life.
- Air Throw Distance: Provides an air throw of up to 30 feet.
- Mosquito Net: Protects against mosquitoes and harmful insects.
- Dust Filter: Ensures pollution-free and clean cooling.
- Blower System: Utilizes a blower for supreme uninterrupted cooling.
- Water Level Indicator: Clearly shows the water tank status.
- Icy Water Inlet: Allows for adding cool or ice water for enhanced cooling.

Figure 2: Front view highlighting key components like the Electronic Control Panel, Automatic Vertical Louvres, Water Tank, and Water Level Indicator.

Figure 3: Rear view showing components such as Dust Pre-Filters, Water Overflow hole, Water Tank, and Water Drain Valve.
4. Setup Guide
Follow these steps for the initial setup of your air cooler:
- Unpacking: Carefully remove the air cooler from its packaging. Check for any damage during transit.
- Attach Castor Wheels: The cooler comes with 4 castor wheels. Insert them firmly into the designated slots at the bottom of the unit.
- Placement: Position the cooler on a flat, stable surface. For optimal cooling, place it near a window or door to allow for cross-ventilation.
- Initial Water Fill: Open the water inlet and fill the tank with clean water. Observe the water level indicator to avoid overfilling. For enhanced cooling, you may add ice or chilled water.
- Power Connection: Plug the power cord into a suitable electrical outlet.

Figure 4: Side view of the Symphony Diet 22i Air Cooler, showing its compact tower design.
5. Operating Your Air Cooler
5.1 Control Panel and Remote
The Symphony Diet 22i can be operated using the electronic control panel on the unit or the full-function remote control. The remote control offers convenience, allowing you to adjust settings from a distance. A dedicated remote placing dock is integrated into the unit for storage.
- Power Button: Turns the cooler ON/OFF.
- Speed Control: Adjusts the blower speed (3 settings available).
- Cooling Mode: Activates or deactivates the water pump for evaporative cooling.
- Swing Function: Controls the automatic vertical louvre movement for wider air distribution.
- Timer: Sets the cooler to operate for up to 7 hours.
- System Restore: The cooler will remember your last settings upon restart.
5.2 Filling the Water Tank
The water tank has a capacity of 22 liters. Use the icy water inlet to fill the tank. Monitor the water level indicator to ensure it does not exceed the maximum fill line. When the water level is low, the empty water tank alarm will sound, and the pump will stop to prevent damage.
5.3 Airflow and Cooling
The cooler uses a powerful blower to deliver air up to 30 feet. The i-Pure Technology, combined with the honeycomb pad and dust filter, ensures that the air circulated is clean and fresh. For effective cooling, ensure there is adequate cross-ventilation in the room.
6. Maintenance and Care
Regular maintenance ensures optimal performance and longevity of your Symphony Diet 22i Air Cooler.
- Cleaning the Exterior: Wipe the exterior surfaces with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Draining the Water Tank: Regularly drain the water tank, especially if the cooler will not be used for an extended period. Use the water drain valve at the back of the unit. This prevents stagnant water and odor.
- Cleaning Filters and Pads: The dust filter and honeycomb pads should be cleaned periodically. Refer to Figure 3 for the location of the dust pre-filters. Gently remove and rinse them under running water. Ensure they are dry before re-installing.
- Mosquito Net: Inspect and clean the mosquito net as needed to maintain airflow and hygiene.
- Dura Pump: The Dura Pump Technology is designed for long life, but ensure the water tank is never completely dry during operation to protect the pump.
7. Troubleshooting
Refer to the table below for common issues and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Cooler does not turn on | No power supply; Power cord not plugged in; Fuse blown. | Check power outlet; Ensure cord is securely plugged in; Check household fuse/breaker. |
| No cooling effect | Water tank empty; Cooling mode not activated; Insufficient ventilation. | Fill water tank; Activate cooling mode; Open windows/doors for cross-ventilation. |
| Water leakage | Overfilled water tank; Drain plug not secured; Damaged water pump/hose. | Do not overfill; Ensure drain plug is tight; Contact customer support for inspection. |
| Unpleasant odor | Stagnant water in tank; Dirty cooling pads. | Drain and clean water tank; Clean or replace cooling pads. |
| Remote control not working | Dead batteries; Obstruction between remote and cooler. | Replace batteries; Ensure clear line of sight to the cooler's receiver. |
8. Technical Specifications
| Specification | Detail |
|---|---|
| Brand | Symphony |
| Model Name | Diet 22i |
| Mounting Type | Freestanding |
| Colour | White |
| Air Flow Capacity | 1350 Cubic Meters Per Hour |
| Controls Type | Remote |
| Reservoir Capacity | 22 Liters |
| Floor Area Coverage | Up to 150 Sq Ft (14 Square Meters) |
| Included Components | Air cooler, 4 castor wheels, Remote, User manual card and Warranty card |
| Noise Level | 65 dB |
| Number of Speeds | 3 |
| Product Dimensions (D x W x H) | 33D x 30W x 93.2H Centimeters |
| Amperage | 0.77 Amps |
| Voltage | 127 Volts |
| Item Weight | 8 kg |

Figure 5: Product dimensions diagram for the Symphony Diet 22i Air Cooler.
9. Warranty and Customer Support
Your Symphony Diet 22i Air Cooler comes with a 1 Year Warranty from the date of purchase. Please retain your purchase receipt for warranty claims.
For any service, support, or warranty-related inquiries, please contact Symphony customer service. Contact details can typically be found on the warranty card included with your product or on the official Symphony website.
Legal Disclaimer: Subject to Indore Jurisdictions.